The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
INSTALL DOOR VIEWING DEVICE | MISSING PEEPHOLE AT 2ND AND 3RD VARIOUS DOORS | 509 E 79TH ST | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | NO SMOKE DETECTOR FRONT STAIRS | 509 E 79TH ST | PERIODIC | FAILED | View |
FLOOR, KIT & BATH NON-ABSORB | 511-2R KITCHEN FLOOR TILES BROKEN | 509 E 79TH ST | PERIODIC | FAILED | View |
INT WALL/CEILING PEELING PAINT | WATER DAMAGE CEILING TILES 1ST FLOOR REAR ESTATE OFFICE | 509 E 79TH ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH SYSTEM NO BOLTED CONVERSION OF STRINGERS RAILS, COLUMNS OR BEAMS DECK WARPED AND BUCKLED RAILS 36" 6X6 COLUMN AT 2ND LEVEL ARE RESTING ON 6X6 LOOKOUT NO LAPP JOINTS STRINGERS OVER CUT SUBMIT [PLANS AND OBTAIN PERMITS | 509 E 79TH ST | PERIODIC | FAILED | View |
INSTALL DOOR VIEWING DEVICE | MISSING PEEPHOLE AT 2ND AND 3RD VARIOUS DOORS | 509 E 79TH ST | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | SMOKE DETECTOR - MISSING | 509 E 79TH ST | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN WINDOW AT STORE FRONT 511 | 509 E 79TH ST | PERIODIC | FAILED | View |
DEFECTIVE FIXTURES | BROKEN LIGHT FIXTURE AT FRONT OF 511 | 509 E 79TH ST | PERIODIC | FAILED | View |
FLOOR, KIT & BATH NON-ABSORB | 511-2R KITCHEN FLOOR TILES BROKEN | 509 E 79TH ST | PERIODIC | FAILED | View |
INT WALL/CEILING PEELING PAINT | OFFICE - MILDEWY SUBSTANCE, WATER STAINS ON WALL WHERE CEILING COLLAPSED. | 509 E 79TH ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | STAIRS - SPINDLES MISSING AT HANDRAILS; LOOSE TREADS; LOOSE, WEAK DECKBOARDS; BOTH STRUCTURES MOVE AND SWAY WHEN ASCENDING/DESCENDING#509 - STRINGER LEANING FORWARD - UNSTABLE, FALL AND TRIP HAZARD; HOLE IN 3RD FLOOR DECK; 2X4 SUPPORTING UNDERSIDE OF STRINGER. #511 - TREADS CUPPING; RAIL AT 3RD FLOOR NOT SECURED TO COLUMN - LOOSE AND DANGEROUS.PLANS AND PERMIT REQUIRED TO REPLACE EXTERIOR STAIR SYSTEM. | 509 E 79TH ST | PERIODIC | FAILED | View |
REPLACE D&H PORCH | REAR PORCHES - FOUNDATION STATUS UNKOWN; 6X6 COLUMNS STACKED, TOENAILED AND TWISTING AT 3RD FLOOR; STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; PORCHES SHAKE AND SWAY WHEN STANDING UPON 3RD FLOOR DECKS - VERY SHAKY AND UNSTABLE; SPLICE JOINTS ONLY 12" IN LENGTH WITH TWO (2) BOLTS; WINDERS NOT SUPPORTED UNDERNEATH; HANDRAIL HEIGHT ONLY 27" AT NOSING; RAIL HEIGHT ONLY 36"; DECKBOARDS WEAK, BUCKLING THRU-OUT; LOOSE RAILS, TREADS AND WINDERS THRU-OUT; RAILS TOENAILED TO COLUMNS - NOT BOLTED TO EXTERIOR WALL; NAILS PROTRUDING THRU-OUT.#509 - REAR PORCH - STRINGERS OVERCUT FROM GRADE TO 1ST FLOOR; HOLES IN 1ST, 2ND FLOOR DECKBOARDS; HANDRAIL FROM GRADE TO 1ST FLOOR LANDING LEANING.#509 - CATWALK - GUARDRAILS MISSING AT 2ND FLOOR LEVEL; PARAPET WALL IS ONLY 17" TALL - FALL HAZARD; DECKBOARDS ARE VERY LOOSE, UNSECURED, BROKEN, AND CUPPING IN SOME AREAS.#511 - REAR PORCH - STRINGERS SPLITTING FROM GRADE TO 2ND FLOOR.#511 CATWALK - HOLES IN CATWALK.DANGEROUS AND HAZARDOUS. PLANS AND PERMIT REQUIRED TO REPLACE EXTERIOR STAIR SYSTEMS. | 509 E 79TH ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | REAR DOOR - RUSTING | 509 E 79TH ST | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | GUARDRAILS MISSING AT GRADE FOR BASEMENT AREAWAY AND 2ND FLOOR ROOF TOP (#509). | 509 E 79TH ST | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | OFFICE - CEILING HAS COLLAPSED; BROKEN, MISSING DRYWALL, ACOUSTIC TILES; HOLE IN CEILING.#511-2R - BEDROOM CEILING SAGGING; PAINT BUBBLING; WATER LEAKING AT CEILING. | 509 E 79TH ST | PERIODIC | FAILED | View |
REPAIR FLOOR | SOT SPOTS, VOIDS, WEAK FLOORBOARDS THRU-OUT STOREFRONT | 509 E 79TH ST | PERIODIC | FAILED | View |
REPAIR DOOR HARDWARE | DOORKNOB MISSING AT HALLWAY DOOR | 509 E 79TH ST | PERIODIC | FAILED | View |
PROVIDE DEADLOCK FOR ENTRANCE | DEADBOLT LOCK MISSING | 509 E 79TH ST | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | BASEMENT AREAWAYS - CLUTTERED WITH DEBRIS, LEAVES, TRASH. | 509 E 79TH ST | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | CLUTTERED WITH STORAGE, JUNK. | 509 E 79TH ST | PERIODIC | FAILED | View |
STOP SMOKE, NOXIOUS ODORS | OFFICE - MILDEWY SMELL IN OFFICE WHERE CEILING COLLAPSED. | 509 E 79TH ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY; UNABLE TO INSPECT MOST APARTMENTS, #511 STOREFRONT AND BASEMENT (VACANT). UNVERIFIED DETECTORS AND OCCUPANCY. | 509 E 79TH ST | PERIODIC | FAILED | View |
NOTIFY DOB, USE OF VACANT LND | VACANT AND SECURED. | 509 E 79TH ST | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | NO SMOKE DETECTOR FRONT STAIRS | 509 E 79TH ST | PERIODIC | FAILED | View |
STOP LEAKING WATER | BEDROOM - WATER LEAKING AT CEILING. | 509 E 79TH ST | PERIODIC | FAILED | View |
VACANT BUILDING - REGISTER | 509 E 79TH ST | COMPLAINT | CLOSED | View | |
FILE BLDG REGISTRATION | REGISTER BUILDING | 509 E 79TH ST | COMPLAINT | FAILED | View |
PARAPET & COPING | OPEN MORTAR JOINTS NORTH PARAPET | 509 E 79TH ST | COMPLAINT | FAILED | View |
REPAIR EAVES | MISSING ONE PIECE OF FACIA BOARD AT 509 ABOVE 1ST FLOOR | 509 E 79TH ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 2-3 STORY FRAME PORCH, OPEN SCATTLE, MATCH, UNDERSIZED WEAK GUARDRAILS, ROTTED & GROOVE DECLINING, UNBROWN FOUNDATION FOR TWO UPRIGHTS | 509 E 79TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | BOTH SOUTH BASEMENT STAIRWELL MISSING HANDRAILS BASEMENT TO GRADE | 509 E 79TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | BOARDED 3RD FLOOR SOUTH AT 511 EAST | 509 E 79TH ST | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | BROKEN LIGHT FIXTURE AT FRONT OF 511 | 509 E 79TH ST | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN WINDOW AT STORE FRONT 511 | 509 E 79TH ST | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | NOT REGISTERED 2000-2010 | 509 E 79TH ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE | 509 E 79TH ST | COMPLAINT | FAILED | View |
CHIMNEY | LOOSE & MISSING BRICKS SOUTH CHIMNEY | 509 E 79TH ST | COMPLAINT | FAILED | View |