The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
HEATING PLANT SEPARATION | CEILING - LOOSE HANGING PLASTER, EXPOSED LATHE AND FLOOR JOIST. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S / MANAGEMENT SIGN POSTED. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
FILE BLDG REGISTRATION | NO OWNER'S / MANAGEMENT SIGN POSTED. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING ALL PLUMBING AND ELECTRICAL) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
RATS | RAT DROPPINGS THRU-OUT BASEMENT. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
REPAIR/REPLACE SMOKE DETECTORS | BOILER ROOM - NON-WORKING SMOKE DETECTOR.REAR ENCLOSED PORCH - NON WORKING SMOKE DETECTOR AT TOP. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | WALLS - WATER DAMAGE WITH BLACK MILDEW SPOTS ALL OVER. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
1-HR STAIR ENCLOSURE, <3 STORY | WALLS OF ENCLOSED PORCH HAVE PANELING INSTALLED WITH NO FIRE RATING. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
FIRE EXTNGSHR RECHARGE & TAG | NO TAGS PRESENT ON FIRE EXTINGUISHERS. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR HARDWARE | DOOR WILL NOT CLOSE AND LOCK PROPERLY. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
SERVICE WALK, PASSAGE, AREAWAY | ALL SERVICE WALKS WITH BUCKLED AND FRACTURED CONCRETE. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
CHIMNEY | SPALLING BRICKS AND WASHED OUT MORTAR. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | MINOR SPALLED BRICKS AND WASHED OUT MORTAR. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
INSTALL DOOR VIEWING DEVICE | MISSING PEEP HOLES. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR SILL | FRONT ENTRY - DOOR SILL FRACTURED. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE - BROKEN WINDOWS, SOUTH ELEVATION MINOR SPALLING BRICKS AND WASHED OUT MORTAR. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO IT'S ORIGINAL STATE. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT GATE DOUBLE CYLINDER LOCK | 2325 N AUSTIN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | FRONT MAIN ENTRANCE DOOR DAMAGED AND REAR PORCH DOOR DAMAGED ROTTED FRAME. | 2325 N AUSTIN AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | FRONT INTERIOR STAIRWAY/ SMOKE DETECTOR - OUT OF SERVICE. | 2325 N AUSTIN AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS, LAYOUT AND OCCUPANCY. UNABLE TO INSPECT SOME INTERIOR STAIRWAYS, REAR ENCLOSED PORCH, FRONT BALCONIES AND SOUTH EXTERIOR ELEVATION. UNABLE TO VERIFY COMPLAINT OF RATS, ROACHES AND MILDEW IN APT. 2. | 2325 N AUSTIN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | FRONT MAIN ENTRANCE DOOR DAMAGED AND REAR PORCH DOOR DAMAGED ROTTED FRAME. | 2325 N AUSTIN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION FRONT METAL BALCONY GUARD RAILS RUSTED | 2325 N AUSTIN AVE | COMPLAINT | FAILED | View |
REPAIR SKYLIGHT | FRONT INTERIOR STAIRWAY/ SKYLIGHT - CRACKED PANES. | 2325 N AUSTIN AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | FRONT STAIRWELL WALLS WATER DAMAGED. | 2325 N AUSTIN AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | SMOKE DETECTORS BEEPING IN UNITS. | 2325 N AUSTIN AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT GATE DOUBLE CYLINDER LOCK | 2325 N AUSTIN AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | STORAGE ON REAR PORCH BLOCKING INGRESS AND EGRESS. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | GARBAGE THRU-OUT YARD. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | 1. 4X4 COLUMN RESTING ON CONCRETE SLAB.2. FOUNDATION STATUS UNKNOWN.3. 4X4 COLUMNS USED FOR SUPPORT OVER 12 FEET IN HEIGHT.4. LAPJOINTS ON COLUMNS NAILED.5. STRINGERS INADEQUATELY SUPPORTED.6. 2X8 JOIST INADEQUATELY SUPPORTED AT BEAM.7. LEDGER BEAM INADEQUATELY SUPPORTED TO BUILDING.8. 2X8 JOIST SUPPORTED BY WALL, WAL RESTING ON CONCRETE SLAB.9. PLANS AND PERMIT REQUIRED. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT GATE DOUBLE CYLINDER LOCK | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION FRONT METAL BALCONY GUARD RAILS RUSTED | 2325 N AUSTIN AVE | COMPLAINT | FAILED | View |
1-HR STAIR ENCLOSURE, <3 STORY | INTERIOR STAIRWAYS AND SOFFITS - BASEMENT TO 2ND FLOOR MISSING FIRE RATING - OPEN HOLES IN SOFFITS - FURNACE UNDER STAIRS - DANGEROUS AND HAZARDOUS. PLANS AND PERMITS REQUIRED. | 2325 N AUSTIN AVE | COMPLAINT | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | INTERIOR - FURNACE INSTALLED UNDER STAIRS, HOT WATER HEATER INSTALLED UNDER STAIRS - OPEN TO STAIRWAY, MISSING ENCLOSURE AND PROPER FIRE RATING - VERY DANGEROUS AND HAZARDOUS. PLANS AND PERMITS REQUIRED FOR PROPER FIRE RATED ENCLOSURE IN STAIRWAY. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
COVER OUTLETS AND JBS | BASEMENT CEILING - OPEN ELECTRICAL JUNCTION BOX - FIRE HAZARD. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR, RESET | FRONT MAIN ENTRANCE DOOR DAMAGED AND REAR PORCH DOOR DAMAGED ROTTED FRAME. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION FRONT METAL BALCONY GUARD RAILS RUSTED | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
REPAIR/REPLACE SMOKE DETECTORS | SMOKE DETECTORS BEEPING IN UNITS. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | FRONT STAIRWELL WALLS WATER DAMAGED. | 2325 N AUSTIN AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR TWO STORY ENCLOSED WOOD PORCH - UNKNOWN FOOTINGS; COLUMN TO COLUMN SUPPORT WOOD CRACK JOINTS; STRINGERS UPPER AND LOWER ENDS INADEQUATLY SUPPORTED; TREADS CRACKED;PLANS AND PERMITS FOR ALL PORCH REPAIRS. | 2325 N AUSTIN AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REMOVE ALL JUNK AND ITEMS FROM FRONT STAIRWELLS AND REAR PORCH AREAS. | 2325 N AUSTIN AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | NORTH ELEVATION PLANS AND PERMITS REQUIRED FOR LARGE METAL SHED IN SIDE YARD. | 2325 N AUSTIN AVE | COMPLAINT | FAILED | View |