Last Modification Date: 2024-10-22 @ 11:30 PM
PIN: 16231170360000
Property Address: 1448 S HAMLIN AVE
City - Zip: CHICAGO - 60623
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77091
2023 Tax District: 77113
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 14 Violations
Violation Inspector Comments Address Category Status View
REPAIR PORCH SYSTEM RAIL SECTIONS 34",RAIL CONNECTIONS FAILING.HANDRAILS 30" MEASURED FROM NOSING(34"MINIMUM REQUIRED).2X8X14 JOISTS OVERSPANNED.6X6X7.5 BEAMS OVERSPANNED.STRINGERS UNDERSIZED NO POSITIVE ATTATCHMENT AT LANDINGS.STRINGERS IMPROPERLY DESIGNED TREADS ARE 9"(MIN. 10 NOSING TO NOSING REQUIRED.COLUMNS OVERNOTCHED.DEFICIENT BEAM COLUMN CONNECTION,BEAMS NOTCHED INTO COLUMNS AND SEPERATING.NORTH ROOF BEAM PULLING AND ALMOST COMPLETELY SEPERATED FROM COLUMN.OBTAIN PLANS AND PERMITS TO REPAIR OR REPLACE PORCH SYSTEM 1448 S HAMLIN AVE COMPLAINT CLOSED View
PROVIDE DEADLOCK FOR ENTRANCE PROVIDE DEADLOCKS FOR MAIN ENTRY DOORS 1448 S HAMLIN AVE COMPLAINT CLOSED View
REPAIR EXTERIOR DOOR MAIN ENTRY DOORS DAMAGED 1448 S HAMLIN AVE COMPLAINT CLOSED View
REPAIR EXTERIOR DOOR FRAME MAIN ENTRY DOOR FRAMES DAMAGED 1448 S HAMLIN AVE COMPLAINT CLOSED View
FILE BLDG REGISTRATION REGISTER BUILDING FOR 2000 TO 2011 1448 S HAMLIN AVE COMPLAINT CLOSED View
POST OWNER/MANAGERS NAME/# POST OWNER INFO 1448 S HAMLIN AVE COMPLAINT CLOSED View
POST OWNER/MANAGERS NAME/# BUILDING - OWNER'S I.D. SIGN IMPROPERLY POSTED; MISSING MAILING ADDRESS. 1448 S HAMLIN AVE COMPLAINT FAILED View
PARAPET FRONT, NORTH AND SOUTH ELEVATIONS/ PARAPET WALLS - WASHEDOUT MORTAR. 1448 S HAMLIN AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL NORTH AMD SOUTH ELEVATIONS/ EXTERIOR WALLS - FRACTURED MASONRY WITH WASHEED OUT MORTAR. 1448 S HAMLIN AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR 3-STORY WOOD PORCH/ STRINGERS - UPPER ENDS INADEQUATELY SUPPORTED WITH NAILS ONLY. 2ND TO 3RD STAIRWAY - LOOSE TREADS. 1448 S HAMLIN AVE COMPLAINT FAILED View
CHIMNEY CAPPING CHIMNEY - MISSING CAPPING. 1448 S HAMLIN AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS ALL ELEVATIONS/ BASEMENT WINDOWS - MISSING PANES (BOARDED UP). 1448 S HAMLIN AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS SOUTH AND EAST STAIRWELLS - MISSING SMOKE DETECTORS. 1448 S HAMLIN AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS AND COMPLAINT OF WATER DAMAGE. UNABLE TO INSPECT INTERIOR STAIRWAYS. 1448 S HAMLIN AVE COMPLAINT FAILED View