The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | RAIL SECTIONS 34",RAIL CONNECTIONS FAILING.HANDRAILS 30" MEASURED FROM NOSING(34"MINIMUM REQUIRED).2X8X14 JOISTS OVERSPANNED.6X6X7.5 BEAMS OVERSPANNED.STRINGERS UNDERSIZED NO POSITIVE ATTATCHMENT AT LANDINGS.STRINGERS IMPROPERLY DESIGNED TREADS ARE 9"(MIN. 10 NOSING TO NOSING REQUIRED.COLUMNS OVERNOTCHED.DEFICIENT BEAM COLUMN CONNECTION,BEAMS NOTCHED INTO COLUMNS AND SEPERATING.NORTH ROOF BEAM PULLING AND ALMOST COMPLETELY SEPERATED FROM COLUMN.OBTAIN PLANS AND PERMITS TO REPAIR OR REPLACE PORCH SYSTEM | 1448 S HAMLIN AVE | COMPLAINT | CLOSED | View |
PROVIDE DEADLOCK FOR ENTRANCE | PROVIDE DEADLOCKS FOR MAIN ENTRY DOORS | 1448 S HAMLIN AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR | MAIN ENTRY DOORS DAMAGED | 1448 S HAMLIN AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR FRAME | MAIN ENTRY DOOR FRAMES DAMAGED | 1448 S HAMLIN AVE | COMPLAINT | CLOSED | View |
FILE BLDG REGISTRATION | REGISTER BUILDING FOR 2000 TO 2011 | 1448 S HAMLIN AVE | COMPLAINT | CLOSED | View |
POST OWNER/MANAGERS NAME/# | POST OWNER INFO | 1448 S HAMLIN AVE | COMPLAINT | CLOSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - OWNER'S I.D. SIGN IMPROPERLY POSTED; MISSING MAILING ADDRESS. | 1448 S HAMLIN AVE | COMPLAINT | FAILED | View |
PARAPET | FRONT, NORTH AND SOUTH ELEVATIONS/ PARAPET WALLS - WASHEDOUT MORTAR. | 1448 S HAMLIN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH AMD SOUTH ELEVATIONS/ EXTERIOR WALLS - FRACTURED MASONRY WITH WASHEED OUT MORTAR. | 1448 S HAMLIN AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 3-STORY WOOD PORCH/ STRINGERS - UPPER ENDS INADEQUATELY SUPPORTED WITH NAILS ONLY. 2ND TO 3RD STAIRWAY - LOOSE TREADS. | 1448 S HAMLIN AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY - MISSING CAPPING. | 1448 S HAMLIN AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | ALL ELEVATIONS/ BASEMENT WINDOWS - MISSING PANES (BOARDED UP). | 1448 S HAMLIN AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | SOUTH AND EAST STAIRWELLS - MISSING SMOKE DETECTORS. | 1448 S HAMLIN AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS AND COMPLAINT OF WATER DAMAGE. UNABLE TO INSPECT INTERIOR STAIRWAYS. | 1448 S HAMLIN AVE | COMPLAINT | FAILED | View |