The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REMOVE | 1ST & 2ND DOOR: APARTMENT UNVENTED SPARE HEATERS (13-180-100) | 4810 S MAY ST | COMPLAINT | PASSED | View |
REMOVE | 1ST AND 2ND FLOORS UNVENTED SPACE HEATERS (SEC 13-180-100) | 4810 S MAY ST | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | FRONT STAIR SYSTEM: RAIL LOOSE, TOE NAILED ONLY, ONLY 33" HIGH, STRINGERS NOT BOLTED, COLUMN 4X4 ON BROKEN FOOTING, JOIST UNDERSIZED AND MISSING JOIST HANGERS; OBTAIN PERMIT FOR REPAIRS | 4810 S MAY ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | 2ND FLOOR, FRONT STORM DOOR CLOSER IS BROKEN & 1ST REAR WASHING MACHINE DISCHARGED THRU WALL INTO CATCH BASIN IN REAR YARD | 4810 S MAY ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | PANE BROKEN, REAR STORM DOOR | 4810 S MAY ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | FLOOR BROKEN TILES AT 1ST FLOOR REAR AT WASHING MACHINE (PORCH) & 2ND FLOOR KITCHEN | 4810 S MAY ST | COMPLAINT | FAILED | View |
1-HR STAIR ENCLOSURE, <3 STORY | PORCH: STAIR ENCLOSURE IS NOT FIRE RATED-USE OF FIBER BOARD | 4810 S MAY ST | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | PAINT FLAKING CEILING OF ENCLOSED PORCH | 4810 S MAY ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTOR AT REAR STAIRS | 4810 S MAY ST | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | OBTAIN PERMIT AND SUBMIT PLANS FOR ALTERATIONS TO ATTIC INTO 2 BEDROOMS | 4810 S MAY ST | COMPLAINT | FAILED | View |
1HR SEP-D.U. AND REST OF BLDG | OPEN STUDS AT VARIOUS LOCATION THROUGHOUT ATTIC | 4810 S MAY ST | COMPLAINT | FAILED | View |
REPAIR / REBUILD SHED | MISSING GUARDRAIL AT ATTIC LEVEL OVER STAIRS | 4810 S MAY ST | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | REAR COACH HOUSE: SECTION OF GUTTER IS MISSING AT NORTH BY WEST ELEVATION (SEC. 18-29-1101.2.1) | 4810 S MAY ST | COMPLAINT | FAILED | View |
1-HR STAIR ENCLOSURE, <3 STORY | INTERIOR STAIRS ARE PANELED, NO FIRE RATING AT BACK PORCH | 4810 S MAY ST | COMPLAINT | FAILED | View |
FLAKY INTERIOR PAINT | FLAKING PAINT AR EXTERIOR STONE ALL ELEVATIONS ANS AT EAVES OF STRUCTURE BETWEEN FRONT & REAR BUILDINGS | 4810 S MAY ST | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | REAR GATE HAS A DOUBLE KEY LOCK | 4810 S MAY ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN WINDOWS AT STRUCTURE BETWEEN FRONT AND REAR BUILDINGS | 4810 S MAY ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | OBSTRUCTIONS IN EXIT, 2ND TO 2ST STAIRWAY-AIR CONDITIONERS AND BOXES STORED ON STEPS AND LANDING | 4810 S MAY ST | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | EXTERIOR DOOR AT 2ND FLOOR AT ALLEY IS MISSING GUARDRAIL | 4810 S MAY ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | ATTIC NO CARBON MONOXIDE DETECTOR, 1ST AND 2ND FLOOR. CARBON MONOXIDE DETECTORS DEFECTIVE. | 4810 S MAY ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT EXTERIOR DOOR, 2ND FLOOR BROKEN GLASS | 4810 S MAY ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT GRADE TO 2ND NO PICKETS WEAK AND LOOSE RAILS. | 4810 S MAY ST | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | OBTAIN PERMIT FOR REPAIRS TO PORCH. | 4810 S MAY ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLANS AND PERMIT FOR ALTERATIONS OF ATTIC INTO 2 BEWDROOMS | 4810 S MAY ST | COMPLAINT | FAILED | View |
REMOVE | 1ST FL REAR PORCH DISCHARGE HOSE FROM WASHING MACHINE BEING RUN INTO CATCH BASIN IN REAR YARD. | 4810 S MAY ST | COMPLAINT | FAILED | View |
EXPOSED WIRING | 1ST FLOOR LIVING ROOM AND KITCHEN EXPOSED WIRES CEILING BOXES. | 4810 S MAY ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 2ND FLOOR DEFECTIVE SMOKE DETECTOR, ATTIC DEFECTIVE SMOKE DETECTOR, 1ST FLOOR NO SMOKE DETECTOR. | 4810 S MAY ST | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | FRONT EXTERIOR DOOR, 1ST FLOOR, REAR DOOR: NEED KEYS TO EXIT | 4810 S MAY ST | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | FRONT ENCLOSED PORCH, STTIC, 2ND FLOOR: NO SMOKE DETECTORS; 1ST FLOOR; DEFECTIVE SMOKE ALARM | 4810 S MAY ST | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | ATTIC: NO CARBON MONOXIDE DETECTORS; 1ST AND 2ND FLOOR: DEFECTIVE CARBON MONOXIDE DETECTORS | 4810 S MAY ST | COMPLAINT | PASSED | View |
REPAIR OR REPLACE | NORTH ELEVATION: MISSING SECTION OF GUTTER | 4810 S MAY ST | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLANS AND PERMITS FOR ALTERATIONS OF ATTIC INTO 1 BEDROOM | 4810 S MAY ST | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | FRONT BUILDING: DANGEROUS AND HAZARDOUS FRONT 2-STORY WOOD STAIRS, VERY SHAKY HANDRAILS LEANING. OPEN RISERS (13 STAIRS), STAIRS SYSTEM SWAYS. 4X4 MID-COLUMNS RESTING ON CRACKED CONCRETE FOOTINGS. 4X6 NEWEL POSTS LOOSELY ATTACHED, VERY SHAKEY. GUARDRAILS TOENAILED; PLANS AND PERMITS REQUIRED TO REPLACE FRONT EXTERIOR STAIRS. | 4810 S MAY ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO VERIFY DETECTORS AND INTERIORS CONDITIONS OF FRONT AND REAR BUILDINGS. | 4810 S MAY ST | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REAR BUILDING: EXTERIOR LIGHT FIXTURE MISSING COVERS, EXPOSED BULBS. | 4810 S MAY ST | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | FRONT BUILDING: DANGEROUS AND HAZARDOUS FRONT 2-STORY WOOD STAIRS, VERY SHAKY HANDRAILS LEANING. OPEN RISERS (13 STAIRS), STAIRS SYSTEM SWAYS. 4X4 MID-COLUMNS RESTING ON CRACKED CONCRETE FOOTINGS. 4X6 NEWEL POSTS LOOSELY ATTACHED, VERY SHAKEY. GUARDRAILS TOENAILED; PLANS AND PERMITS REQUIRED TO REPLACE FRONT EXTERIOR STAIRS. | 4810 S MAY ST | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO VERIFY DETECTORS AND INTERIORS CONDITIONS OF FRONT AND REAR BUILDINGS. | 4810 S MAY ST | COMPLAINT | PASSED | View |
DEFECTIVE FIXTURES | REAR BUILDING: EXTERIOR LIGHT FIXTURE MISSING COVERS, EXPOSED BULBS. | 4810 S MAY ST | COMPLAINT | PASSED | View |
HEAT UNIT ADEQUATELY | 61 DEGREES IN APARTMENT. HEATING SYSTEM WAS OFF AT TIME OF INSPECTION. NO HEAT PROVIDED. APARTMENT 1BR. | 4810 S MAY ST | COMPLAINT | PASSED | View |
SAFE WORKING CONDITIONS | SPACE HEATER OUT OF SERVICE AT TIME OF INSPECTION. | 4810 S MAY ST | COMPLAINT | PASSED | View |
EXPOSED WIRING | OPEN JUNCTION BOX AT 1ST REAR OVER ELECTRICAL PANELS | 4810 S MAY ST | COMPLAINT | FAILED | View |