Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | INTERIOR INSPECTION AND PORCHES | 6250 N ROCKWELL ST | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING-NOT REGISTERED FROM 1990 THRU 2009 | 6250 N ROCKWELL ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION AT GRADE-SPALLING BRICKS AND WASHED OUT MORTAR | 6250 N ROCKWELL ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | EAST ENTRY DOOR - ADJUST CLOSET | 6250 N ROCKWELL ST | PERIODIC | FAILED | View |
CHIMNEY | CHIMNEY - LOOSE MORTAR | 6250 N ROCKWELL ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO APARTMENTS, BASEMENT & PORCH | 6250 N ROCKWELL ST | PERIODIC | FAILED | View |
PARAPET | NORTH PARAPET - SPALLING MORTAR | 6250 N ROCKWELL ST | PERIODIC | FAILED | View |
CHIMNEY | CHIMNEY - LOOSE MORTAR | 6250 N ROCKWELL ST | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NEVER REGISTERED. | 6250 N ROCKWELL ST | PERIODIC | FAILED | View |
1HR SEP-D.U. AND REST OF BLDG | NORTH SIDE GANG WAY CEILING- HOLES, CRUMBLING PLASTER AND DRYWALL. EXPOSED LATH, HANGING, LOOSE DRYWALL. | 6250 N ROCKWELL ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR ENCLOSED PORCH- ROTTING POST AT 1RST. STRINGERS, RAILS, POSTS, BEAMS, COLUMNS, ALL MEMBERS ANCHORED WITH NAILS ONLY. BEAM SPLICES ARE BUTT JOINT AND ARE ANCHORED WITH NAILS ONLY. CRACKED/ SPLIT STRINGERS AT 1RST. ROTTING HEADER/ JOIST AT 1RST. ROTTING STRINGER AT 1RST. ROTTING HEADER AT LANDING BETWEEN 1 AND 2. ROTTING JOISTS. LANDING JOISTS ANCHORED WITH NAILS ONLY. ROTTING 6X6 COLUMNS AT BASE. WORN TREADS. NON CONTINUOS STRINGERS WITH BUTT JOINT SPLICES AND NO SISTERED SUPPORT. THIS LOCATION BETWEEN 1RST LANDING AND SECOND FLOOR HAS SHIFTED. NON CONTINUOS AND SCABBED STRINGERS AT 2. ROTTING JOISTS AT LANDING BEFORE 3. ROTTING LANDING BEA, BEFORE 3. ROTTING HEADER AT 3. TOE NAILED HEADERS TO COLUMNS. OBTAIN COMPLETE PLAN AND PERMIT. | 6250 N ROCKWELL ST | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | NO SMOKE DETECTOR TOP OF REAR ENCLOSED PORCH. | 6250 N ROCKWELL ST | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FOR 2013. | 6250 N ROCKWELL ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID SIGN - MISSING. | 6250 N ROCKWELL ST | COMPLAINT | FAILED | View |
PARAPET | SOUTHWEST PARAPET WALL - WASHED OUT MORTAR WITH PART OF CHIMNEY - WASHED OUT MORTAR. | 6250 N ROCKWELL ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTHEAST WALL - STEP FRACTURES. WEST WALL AT 3RD - LOOSE AND BROKEN PARGE COAT. | 6250 N ROCKWELL ST | COMPLAINT | FAILED | View |
RAT STOP AROUND EXTERIOR | EAST AT BUILDING - RAT HOLES. | 6250 N ROCKWELL ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR - NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAYS. | 6250 N ROCKWELL ST | COMPLAINT | FAILED | View |
RATS | EAST YARD AND NORTH SERVICE WALK - RATS. | 6250 N ROCKWELL ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNERSHIP POSTED | 6250 N ROCKWELL ST | PERIODIC | FAILED | View |
PARAPET | NORTH PARAPET - SPALLING MORTAR | 6250 N ROCKWELL ST | PERIODIC | FAILED | View |