Chicago Building Violations Data: 21 Violations
Violation Inspector Comments Address Category Status View
ARRANGE PREMISE INSPECTION INTERIOR INSPECTION AND PORCHES 6250 N ROCKWELL ST PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING-NOT REGISTERED FROM 1990 THRU 2009 6250 N ROCKWELL ST PERIODIC FAILED View
REPAIR EXTERIOR WALL NORTH ELEVATION AT GRADE-SPALLING BRICKS AND WASHED OUT MORTAR 6250 N ROCKWELL ST PERIODIC FAILED View
REPAIR EXTERIOR DOOR HARDWARE EAST ENTRY DOOR - ADJUST CLOSET 6250 N ROCKWELL ST PERIODIC FAILED View
CHIMNEY CHIMNEY - LOOSE MORTAR 6250 N ROCKWELL ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO APARTMENTS, BASEMENT & PORCH 6250 N ROCKWELL ST PERIODIC FAILED View
PARAPET NORTH PARAPET - SPALLING MORTAR 6250 N ROCKWELL ST PERIODIC FAILED View
CHIMNEY CHIMNEY - LOOSE MORTAR 6250 N ROCKWELL ST PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING NEVER REGISTERED. 6250 N ROCKWELL ST PERIODIC FAILED View
1HR SEP-D.U. AND REST OF BLDG NORTH SIDE GANG WAY CEILING- HOLES, CRUMBLING PLASTER AND DRYWALL. EXPOSED LATH, HANGING, LOOSE DRYWALL. 6250 N ROCKWELL ST PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR ENCLOSED PORCH- ROTTING POST AT 1RST. STRINGERS, RAILS, POSTS, BEAMS, COLUMNS, ALL MEMBERS ANCHORED WITH NAILS ONLY. BEAM SPLICES ARE BUTT JOINT AND ARE ANCHORED WITH NAILS ONLY. CRACKED/ SPLIT STRINGERS AT 1RST. ROTTING HEADER/ JOIST AT 1RST. ROTTING STRINGER AT 1RST. ROTTING HEADER AT LANDING BETWEEN 1 AND 2. ROTTING JOISTS. LANDING JOISTS ANCHORED WITH NAILS ONLY. ROTTING 6X6 COLUMNS AT BASE. WORN TREADS. NON CONTINUOS STRINGERS WITH BUTT JOINT SPLICES AND NO SISTERED SUPPORT. THIS LOCATION BETWEEN 1RST LANDING AND SECOND FLOOR HAS SHIFTED. NON CONTINUOS AND SCABBED STRINGERS AT 2. ROTTING JOISTS AT LANDING BEFORE 3. ROTTING LANDING BEA, BEFORE 3. ROTTING HEADER AT 3. TOE NAILED HEADERS TO COLUMNS. OBTAIN COMPLETE PLAN AND PERMIT. 6250 N ROCKWELL ST PERIODIC FAILED View
INSTALL SMOKE DETECTORS NO SMOKE DETECTOR TOP OF REAR ENCLOSED PORCH. 6250 N ROCKWELL ST PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING NOT REGISTERED FOR 2013. 6250 N ROCKWELL ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING OWNER'S ID SIGN - MISSING. 6250 N ROCKWELL ST COMPLAINT FAILED View
PARAPET SOUTHWEST PARAPET WALL - WASHED OUT MORTAR WITH PART OF CHIMNEY - WASHED OUT MORTAR. 6250 N ROCKWELL ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL NORTHEAST WALL - STEP FRACTURES. WEST WALL AT 3RD - LOOSE AND BROKEN PARGE COAT. 6250 N ROCKWELL ST COMPLAINT FAILED View
RAT STOP AROUND EXTERIOR EAST AT BUILDING - RAT HOLES. 6250 N ROCKWELL ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION BUILDING INTERIOR - NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAYS. 6250 N ROCKWELL ST COMPLAINT FAILED View
RATS EAST YARD AND NORTH SERVICE WALK - RATS. 6250 N ROCKWELL ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO OWNERSHIP POSTED 6250 N ROCKWELL ST PERIODIC FAILED View
PARAPET NORTH PARAPET - SPALLING MORTAR 6250 N ROCKWELL ST PERIODIC FAILED View