The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | IMPROPER FOOTING MISSING JOIST HANGERS LEDGER NOT BOLTED HANDRAILS LOOSE., NO PLANS ON SIGHT. | 6339 S RACINE AVE | PERMIT | FAILED | View |
INSPECT CONSTRUCTION WORK | CALL 312-743-1000 TO SCHEDULE PORCH PERMIT INSPECTION APPOINTMENT -MUST HAVE PLANS AND PERMIT ON SITE. | 6339 S RACINE AVE | PERMIT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | NO HOT WATER AT 1ST FLOOR APARTMEMT, UNABLE TO VERIFY OWNER RESPONSIBILITY | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
SUBMIT FOR APPROVAL PLANS | 6339 S RACINE AVE | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 6339 S RACINE AVE | COMPLAINT | CLOSED | View | |
WATCHMAN | 6339 S RACINE AVE | COMPLAINT | CLOSED | View | |
POST OWNER NAME OF VACNT BLDG | 6339 S RACINE AVE | COMPLAINT | CLOSED | View | |
FILE BLDG REGISTRATION | 6339 S RACINE AVE | COMPLAINT | CLOSED | View | |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID SIGN NOT POSTED. | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT EXTERIOR STAIRS MISSING GUARD RAILS, BROKEN STRINGERS, COLUMNS COMING OF THE PEDESTAL, FLOOR JOISTS ATTACHED WITH NAILS ONLY. PERMIT | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT BUILDING REAR 2 STORY WOOD PORCH GUARD RAILS ARE OVER SPANNED NOT PROPERLY ATTACHED TO THE BUILDING, 36" IN HEIGHT. LEDGER BOARD WITH INSUFFICIENT BOLTS ATTACHED TO BUILDING. COLUMNS ERECTED ON CONCRETE BLOCKS. GUARD RAILS ARE HORIZONTAL ON STAIRS. PLANS AND PERMIT REQUIRED FOR PORCH PERMIT ISSUED ON 9 -30 -2005 #100070483 NOT SIGNED OFF | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT BUILDING,EAST PORCH; UPRIGHT TWISTED,SPLIT AND BOWED,TREADS WOOD SPLIT,HAND RAILS LOOSE, WEST PORCH STRINGER BROKEN. REAR BUILDING,WEST PORCH; TREADS AND HAND RAILS BROKEN [SUBMIT PERMITS FOR REPAIRS]. | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP ON BUILDING. | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | REAR BUILDING, WEST EAVES; BROKEN AND SIDING CAP MISSING. | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR FRONT AND REAR BUILDING. | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
RAT PROOF OPENINGS | REAR BUILDING, BUILDING AREA RAT HOLES. | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
VACANT BUILDING - REGISTER | VIOLATION CLOSED PER PCR 1180 | 6339 S RACINE AVE | COMPLAINT | CLOSED | View |
ABANDONED REFRIGERATOR | REAR PORCH 2ND FLOOR - ABANDONED REFRIGERATOR. | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | FRONT AND REAR BUILDINGS , UNVERIFIED CONDITIONS , OCCUPANCY AND DETECTORS . | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED | PERMIT FOR IRON FENCE AND GATE. | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
REPAIR/WRECK DANGER RESID PREM | 6339 S RACINE AVE | COMPLAINT | CLOSED | View | |
REPLCE WINDOW PANES, PLEXGLAS | BUILDING FRONT WINDOW IS PLYWOOD COVERED. | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - POSTED OWNER'S I.D. SIGN MISSING COMPLETE MAILING ADDRESS . | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | FRONT YARD SIX FOOT HIGH IRON FENCE GATE BROKEN OFF HINGES . FRONT AND REAR SIX FOOT IRON FENCE AND GATES NO PERMITS OBTAINED . | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
DEMO DEBRIS | FRONT BUILDING , UNDER FRONT PORCH BROKEN CONCRETE PILED , RAT HOLES , RAT HARBORAGE . | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | FRONT BUILDING , SOUTH EAST DOWNSPOUT SMASHED , DENTED , MISSING LOWER SECTION . | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | REAR BUILDING , GUTTER AND DOWNSPOUT MISSING SECTION AT NORTHEAST . | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | FRONT BUILDING , FRONT ELEVATION FOUNDATION , OPEN MORTAR JOINTS IN STONES UNDER PORCH . EAST AND WEST ELEVATIONS , SPALLED AND LOOSE MASONRY PARGING COATING , REMOVE MASONRY PARGING AND RESTORE BRICKWORK TO ORIGINAL . | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | FRONT BUILDING - SIDING LOOSE AND BUCKLED AT NORTH AND SOUTH ELEVATION . REAR ELEVATION AT GRADE , SPALLED BRICKS AND OPEN MORTAR JOINTS . | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | FRONT BUILDING - REAR EXTERIOR BASEMENT AREAWAY MISSING ALL GUARDRAILS AND HANDRAILS . | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
INSPECT CONSTRUCTION WORK | FRONT BUILDING - PERMIT # 100459878 FOR "REPLACE 3 GANG METER ON 100 AMP SERVICE " NO PERMITS AVAILABLE FOR INSPECTORS REVIEW , SUBJECT TO FIELD INSPECTION AND REVIEW BY ALL RELATED TRADES . | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT BUILDING FRONT ONE STORY WOOD PORCH , UNKNOWN FOUNDATION STATUS WITH UPRIGHTS SET ON CONCRETE BLOCKS . LEDGER BOARD ONLY NAILED TO BUILDING . RIM BEAMS AND FLOOR JOIST ONLY NAILED TO COLUMNS . NO STAIR HEADER SUPPORT . HANDRAILS AND GUARDRAILS ONLY NAILED TO COLUMNS . PERMIT REQUIRED .REAR BUILDING FRONT PORCH , FRONT ONE STORY WOOD PORCH , UNKNOWN FOUNDATION STATUS WITH UPRIGHTS SET ON CONCRETE BLOCKS . LEDGER BOARD ONLY NAILED TO BUILDING . RIM BEAMS AND FLOOR JOIST ONLY NAILED TO COLUMNS . NO STAIR HEADER SUPPORT . HANDRAILS AND GUARDRAILS ONLY NAILED TO COLUMNS . PERMIT REQUIRED .FRONT BUILDING REAR TWO STORY WOOD PORCH , UNKNOWN FOUNDATION STATUS . COLUMN LAP JOINTS INSUFFICIENT CONNECTIONS . COLUMN AT NORTH TWISTED AT ROOF . BEAMS ONLY NAILED TO COLUMNS WITHOUT HEAVY DUTY BRACKETS , NO FLOOR SUPORT .LEDGER ONLY NAILED TO BUILDING . NO STAIR HEADER SUPPORT . PICKETS MISSING FROM ALL STAIR HANDRAILS .PERMIT REQUIRED FOR REPAIRS . | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | REAR BUILDING - NORTH ELEVATION CENTER WINDOW BROKEN GLASS PANE . | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD AND UNDER REAR PORCH - DISCARDED LUMBER JUNK AND REFUSE ACCUMULATION. | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | WEST ELEVATION 2ND FLOOR - MISSING WINDOW SASH, OTHER IS LOOSE. | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH BASEMENT WINDOWS - BROKEN VENT GASS PANES. | 6339 S RACINE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | COACH HOUSE, FRONT PORCH - LOOSE GUARD AND HANDRAILS, ROTTED TREADS, BROCKEN DECK BOARDS.; LEDGER BOARD FASTENED WITH NAILS ONLY, PORCH SWAYS, POSTS ERECTED ON TOP OF CONCRETE BASES, NO FOOTINGS. PORCH IS IN D&H CONDITION.FRONT BUILDING REAR 2 STORY PORCH - GUARDRAILS - MISSING PICKETS, STAIRS LOOSE AND BROKEN TREADS, STRINGERS FASTENED WITH NAILS ONLY, GUARDRAILS OVER 4'-0" LONG - MISSING INTERMEDATE 4"X4", GRADE TO 1ST -LOOSE HANDRAILS.; LEDGER BOARD BOLTS ARE APROX 24" O.C. AND ONLY ONE PER STUD. TREADS ARE ONLY 9-1/4". PLANS AND PERMIT ARE REQUIRED TO REPAIR OR REPLACE PORCHES. | 6339 S RACINE AVE | COMPLAINT | FAILED | View |