Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 5:22 PM
PIN: 20202000200000
Property Address: 6339 S RACINE AVE
City - Zip: CHICAGO - 60636
2023 Property Class: 211
2023 Township: 72 - Lake
2023 Neighborhood: 72130
2023 Tax District: 72082
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 37 Violations
Violation Inspector Comments Address Category Status View
REPAIR PORCH SYSTEM IMPROPER FOOTING MISSING JOIST HANGERS LEDGER NOT BOLTED HANDRAILS LOOSE., NO PLANS ON SIGHT. 6339 S RACINE AVE PERMIT FAILED View
INSPECT CONSTRUCTION WORK CALL 312-743-1000 TO SCHEDULE PORCH PERMIT INSPECTION APPOINTMENT -MUST HAVE PLANS AND PERMIT ON SITE. 6339 S RACINE AVE PERMIT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG NO HOT WATER AT 1ST FLOOR APARTMEMT, UNABLE TO VERIFY OWNER RESPONSIBILITY 6339 S RACINE AVE COMPLAINT FAILED View
SUBMIT FOR APPROVAL PLANS 6339 S RACINE AVE COMPLAINT CLOSED View
MAINTAN BLDG IN SAFE CONDITION 6339 S RACINE AVE COMPLAINT CLOSED View
WATCHMAN 6339 S RACINE AVE COMPLAINT CLOSED View
POST OWNER NAME OF VACNT BLDG 6339 S RACINE AVE COMPLAINT CLOSED View
FILE BLDG REGISTRATION 6339 S RACINE AVE COMPLAINT CLOSED View
POST OWNER/MANAGERS NAME/# BUILDING OWNER'S ID SIGN NOT POSTED. 6339 S RACINE AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT EXTERIOR STAIRS MISSING GUARD RAILS, BROKEN STRINGERS, COLUMNS COMING OF THE PEDESTAL, FLOOR JOISTS ATTACHED WITH NAILS ONLY. PERMIT 6339 S RACINE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT BUILDING REAR 2 STORY WOOD PORCH GUARD RAILS ARE OVER SPANNED NOT PROPERLY ATTACHED TO THE BUILDING, 36" IN HEIGHT. LEDGER BOARD WITH INSUFFICIENT BOLTS ATTACHED TO BUILDING. COLUMNS ERECTED ON CONCRETE BLOCKS. GUARD RAILS ARE HORIZONTAL ON STAIRS. PLANS AND PERMIT REQUIRED FOR PORCH PERMIT ISSUED ON 9 -30 -2005 #100070483 NOT SIGNED OFF 6339 S RACINE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT BUILDING,EAST PORCH; UPRIGHT TWISTED,SPLIT AND BOWED,TREADS WOOD SPLIT,HAND RAILS LOOSE, WEST PORCH STRINGER BROKEN. REAR BUILDING,WEST PORCH; TREADS AND HAND RAILS BROKEN [SUBMIT PERMITS FOR REPAIRS]. 6339 S RACINE AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# POST OWNERSHIP ON BUILDING. 6339 S RACINE AVE COMPLAINT FAILED View
REPAIR EAVES REAR BUILDING, WEST EAVES; BROKEN AND SIDING CAP MISSING. 6339 S RACINE AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO INTERIOR FRONT AND REAR BUILDING. 6339 S RACINE AVE COMPLAINT FAILED View
RAT PROOF OPENINGS REAR BUILDING, BUILDING AREA RAT HOLES. 6339 S RACINE AVE COMPLAINT FAILED View
VACANT BUILDING - REGISTER VIOLATION CLOSED PER PCR 1180 6339 S RACINE AVE COMPLAINT CLOSED View
ABANDONED REFRIGERATOR REAR PORCH 2ND FLOOR - ABANDONED REFRIGERATOR. 6339 S RACINE AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION FRONT AND REAR BUILDINGS , UNVERIFIED CONDITIONS , OCCUPANCY AND DETECTORS . 6339 S RACINE AVE COMPLAINT FAILED View
PERMIT REQUIRED PERMIT FOR IRON FENCE AND GATE. 6339 S RACINE AVE COMPLAINT FAILED View
REPAIR/WRECK DANGER RESID PREM 6339 S RACINE AVE COMPLAINT CLOSED View
REPLCE WINDOW PANES, PLEXGLAS BUILDING FRONT WINDOW IS PLYWOOD COVERED. 6339 S RACINE AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING - POSTED OWNER'S I.D. SIGN MISSING COMPLETE MAILING ADDRESS . 6339 S RACINE AVE COMPLAINT FAILED View
REPAIR FENCE FRONT YARD SIX FOOT HIGH IRON FENCE GATE BROKEN OFF HINGES . FRONT AND REAR SIX FOOT IRON FENCE AND GATES NO PERMITS OBTAINED . 6339 S RACINE AVE COMPLAINT FAILED View
DEMO DEBRIS FRONT BUILDING , UNDER FRONT PORCH BROKEN CONCRETE PILED , RAT HOLES , RAT HARBORAGE . 6339 S RACINE AVE COMPLAINT FAILED View
REPAIR DOWNSPOUT FRONT BUILDING , SOUTH EAST DOWNSPOUT SMASHED , DENTED , MISSING LOWER SECTION . 6339 S RACINE AVE COMPLAINT FAILED View
REPAIR GUTTER & DOWNSPOUT REAR BUILDING , GUTTER AND DOWNSPOUT MISSING SECTION AT NORTHEAST . 6339 S RACINE AVE COMPLAINT FAILED View
REPAIR DEFECTIVE FOUNDATION FRONT BUILDING , FRONT ELEVATION FOUNDATION , OPEN MORTAR JOINTS IN STONES UNDER PORCH . EAST AND WEST ELEVATIONS , SPALLED AND LOOSE MASONRY PARGING COATING , REMOVE MASONRY PARGING AND RESTORE BRICKWORK TO ORIGINAL . 6339 S RACINE AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL FRONT BUILDING - SIDING LOOSE AND BUCKLED AT NORTH AND SOUTH ELEVATION . REAR ELEVATION AT GRADE , SPALLED BRICKS AND OPEN MORTAR JOINTS . 6339 S RACINE AVE COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH FRONT BUILDING - REAR EXTERIOR BASEMENT AREAWAY MISSING ALL GUARDRAILS AND HANDRAILS . 6339 S RACINE AVE COMPLAINT FAILED View
INSPECT CONSTRUCTION WORK FRONT BUILDING - PERMIT # 100459878 FOR "REPLACE 3 GANG METER ON 100 AMP SERVICE " NO PERMITS AVAILABLE FOR INSPECTORS REVIEW , SUBJECT TO FIELD INSPECTION AND REVIEW BY ALL RELATED TRADES . 6339 S RACINE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT BUILDING FRONT ONE STORY WOOD PORCH , UNKNOWN FOUNDATION STATUS WITH UPRIGHTS SET ON CONCRETE BLOCKS . LEDGER BOARD ONLY NAILED TO BUILDING . RIM BEAMS AND FLOOR JOIST ONLY NAILED TO COLUMNS . NO STAIR HEADER SUPPORT . HANDRAILS AND GUARDRAILS ONLY NAILED TO COLUMNS . PERMIT REQUIRED .REAR BUILDING FRONT PORCH , FRONT ONE STORY WOOD PORCH , UNKNOWN FOUNDATION STATUS WITH UPRIGHTS SET ON CONCRETE BLOCKS . LEDGER BOARD ONLY NAILED TO BUILDING . RIM BEAMS AND FLOOR JOIST ONLY NAILED TO COLUMNS . NO STAIR HEADER SUPPORT . HANDRAILS AND GUARDRAILS ONLY NAILED TO COLUMNS . PERMIT REQUIRED .FRONT BUILDING REAR TWO STORY WOOD PORCH , UNKNOWN FOUNDATION STATUS . COLUMN LAP JOINTS INSUFFICIENT CONNECTIONS . COLUMN AT NORTH TWISTED AT ROOF . BEAMS ONLY NAILED TO COLUMNS WITHOUT HEAVY DUTY BRACKETS , NO FLOOR SUPORT .LEDGER ONLY NAILED TO BUILDING . NO STAIR HEADER SUPPORT . PICKETS MISSING FROM ALL STAIR HANDRAILS .PERMIT REQUIRED FOR REPAIRS . 6339 S RACINE AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS REAR BUILDING - NORTH ELEVATION CENTER WINDOW BROKEN GLASS PANE . 6339 S RACINE AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE REAR YARD AND UNDER REAR PORCH - DISCARDED LUMBER JUNK AND REFUSE ACCUMULATION. 6339 S RACINE AVE COMPLAINT FAILED View
MAINTAIN WINDOW SASH WEST ELEVATION 2ND FLOOR - MISSING WINDOW SASH, OTHER IS LOOSE. 6339 S RACINE AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS SOUTH BASEMENT WINDOWS - BROKEN VENT GASS PANES. 6339 S RACINE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM COACH HOUSE, FRONT PORCH - LOOSE GUARD AND HANDRAILS, ROTTED TREADS, BROCKEN DECK BOARDS.; LEDGER BOARD FASTENED WITH NAILS ONLY, PORCH SWAYS, POSTS ERECTED ON TOP OF CONCRETE BASES, NO FOOTINGS. PORCH IS IN D&H CONDITION.FRONT BUILDING REAR 2 STORY PORCH - GUARDRAILS - MISSING PICKETS, STAIRS LOOSE AND BROKEN TREADS, STRINGERS FASTENED WITH NAILS ONLY, GUARDRAILS OVER 4'-0" LONG - MISSING INTERMEDATE 4"X4", GRADE TO 1ST -LOOSE HANDRAILS.; LEDGER BOARD BOLTS ARE APROX 24" O.C. AND ONLY ONE PER STUD. TREADS ARE ONLY 9-1/4". PLANS AND PERMIT ARE REQUIRED TO REPAIR OR REPLACE PORCHES. 6339 S RACINE AVE COMPLAINT FAILED View