The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED. | 3528 N NORMANDY AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | SOUTH ELEVATION/ GRADE TO 1ST STAIRWAY - LADDER TYPE RAILINGS WITH 7 INCHES BETWEEN MEMBERS.NORTH ELEVATION/ GRADE TO 1ST STAIRWAY - LADDER TYPE RAILINGS WITH 12 INCHES BETWEEN MEMBERS.PERMIT ONLY REQUIRED FOR STAIRWAY REPAIRS. | 3528 N NORMANDY AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | ALL ELEVATIONS/ BASEMENT WINDOWS FRAMES - ROTTED WITH PEELING PAINT. | 3528 N NORMANDY AVE | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | REAR 2-STORY WOOD PORCH/ 4X4 COLUMNS - RESTING ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN. 4X4 COLUMNS - ROTTED. ROOF TOP DECK RIM JOISTS AND DECK JOISTS - ROTTED. STRINGERS - WEAK, ROTTED AND BROKEN; ONLY NAILED TO COLUMNS. STAIR RAILINGS - LOOSE, PULLING, ROTTED AND BROKEN. STAIR RAILINGS - LADDER TYPE WITH 6 TO 8 INCHES BETWEEN MEMBERS AND ONLY NAILED TO 4X4 COLUMNS. RAILINGS - ONLY 33 INCHES HIGH; LOOSE, PULLING, ROTTED AND BROKEN; LADDER TYPE WITH 19 INCHES BETWEEN MEMBERS. TREADS - BROKEN AND ROTTED. DECK BOARDS ROTTED THROUGHOUT. ENTIRE PORCH SYSTEM IS UNSTABLE AND SWAYING.PLANS AND PERMIT REQUIRED TO REPLACE DANGEROUS AND HAZARDOUS PORCH. | 3528 N NORMANDY AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | ALL ELEVATIONS/ BASEMENT WINDOW FRAMES- ROTTING, WITH PEELING PAINT. | 3528 N NORMANDY AVE | COMPLAINT | CLOSED | View |
REPAIR / REBUILD SHED | DILAPIDATED GARAGE- ROOF COLLAPSING. WINDOWS- MISSING PANES. DEMOLITION PERMIT IS REQUIRED TO REMOVE: DILAPIDATED GARAGE. | 3528 N NORMANDY AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS, AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS. UNVERIFIED COMPLAINT OF: ILLEGAL BASEMENT APARTMENT, WITH NO EMERGENCY EXIT [SEE SR#163968370]. | 3528 N NORMANDY AVE | COMPLAINT | CLOSED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES ( INCLUDING PLUMBING AND ELECTRICAL ) INSTALLED IN THE BASEMENT AND ATTIC WITHOUT A PERMIT . REMOVE REAR WOOD FRAMES PORCH AND WOOD CATWALK ACROSS WOOD ENCLOSED PORCH AND SOUTH WOOD FRAMED STAIRS INSTALLED IN BUILDING SIDEYARD . RESTORE THE BUILDING TO THE ORIGINAL STATE . | 3528 N NORMANDY AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO AUTHORIZE ALTERATIONS TO BASEMENT AND ATTIC OR RESTORE THE BUILDING TO THE ORIGINAL STATE . | 3528 N NORMANDY AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | WOOD WINDOWS AND WOOD WINDOWS BEHIND STORM WINDOWS , FLAKING PAINT AND PUTTY . | 3528 N NORMANDY AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT BOILER AREA MISSING CARBON MONOXIDE DETECTOR . | 3528 N NORMANDY AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | FRONT YARD OVERGROWN SHRUBS . | 3528 N NORMANDY AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | REAR FRAME OVERSIZED GARAGE , RAFTERS AND ROOFING SHEETING ROTTED , HOLES , IN DANGER OF COLLAPSE . HAZARD TO TENANTS , OCCUPANTS AND ADJACENT PROPERTIES . | 3528 N NORMANDY AVE | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | FRONT AND REAR YARDS - OVERGROWN BUSHES AND HIGH WEEDS. | 3528 N NORMANDY AVE | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH ELEVATION/ 1ST FLOOR WINDOW- BROKEN PANE. | 3528 N NORMANDY AVE | COMPLAINT | CLOSED | View |
EXPOSED WIRING | ABIOVE REAR EXTERIOR DOOR AT ATTIC LEVEL- EXPOSED WIRES. | 3528 N NORMANDY AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR | NORTH SCUTTLE DOOR , ROTTED PEELED WOOD . | 3528 N NORMANDY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT CONCRETE PORCH FLAKING MASONRY COATING , IRON GUARDRAILS RUSTED WITH FLAKING PAINT . | 3528 N NORMANDY AVE | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' - BASEMENT | BASEMENT DWELLING UNIT - CEILING HEIGHT 6 FOOT 7 INCHES HALL . | 3528 N NORMANDY AVE | COMPLAINT | FAILED | View |
EGRESS -BASEMENT | BASEMENT DWELLING UNIT - ONLY ONE EGRESS EXISTS ( IN THE REAR ) | 3528 N NORMANDY AVE | COMPLAINT | FAILED | View |