Last Modification Date: 2024-10-24 @ 3:54 PM
PIN: 16114100250000
Property Address: 3458 W LAKE ST
City - Zip: CHICAGO - 60624
2023 Property Class: 212
2023 Township: 77 - West Chicago
2023 Neighborhood: 77102
2023 Tax District: 77121
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 43 Violations
Violation Inspector Comments Address Category Status View
FILE BLDG REGISTRATION BUILING NOT REGISTERED 1990-2006 3458 W LAKE ST PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# BUILDING POST MANAGEMENT SIGN 3458 W LAKE ST PERIODIC FAILED View
FIRE EXTNGSHR RECHARGE & TAG 1ST (STORE) RECHARGE AND TAG FIRE EXTINGUSHIERS 3458 W LAKE ST PERIODIC FAILED View
CONTINUITY OF RACEWAYS PROVIDE GROUND CONTINUITY FOR LIGHT FIXTURE THROUGHOUT CEILING AREA, FIXTURE BY WALK-IN COOLER AREA AND INSIDE OF WALK-IN COOLER AREA WITH BARE WIRES. (DANGEROUS AND HAZARDOUS CONDITION) 3458 W LAKE ST COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS BROKEN WINDOWS 2ND FLOOR. (DANGEROUS AND HAZARDOUS) 3458 W LAKE ST COMPLAINT FAILED View
BLOCKED FIRE DOOR REAR EXTERIOR AT REAR EXIT EXCESSIVE JUNK AND DEBRIS. ALSO BLOCKING REAR EXIT. (DANGEROUS AND HAZARDOUS) 3458 W LAKE ST COMPLAINT FAILED View
SUPPLEMENTAL GROUND PROVIDE SUPPLEMENTAL GROUND FOR METER BANK AREA. 3458 W LAKE ST COMPLAINT FAILED View
ABANDONED EQUIPMENT REMOVE ALL ABANDONED EXTERIOR LIGHTS AND JUNCTION BOXES AND IN INTERIOR CEILING AREA REMOVE ALL ABANDONED JUNCTION BOXES AND CONDUIT RUNS. 3458 W LAKE ST COMPLAINT FAILED View
OPEN NO FLOOR DRAIN AT EMPLOYEE BATHROOM. (18-29-412.4.3) 3458 W LAKE ST COMPLAINT FAILED View
SECURE RACEWAY PROPERLY SUPPORT ALL JUNCTION BOXES AND LIGHTS AT EXTERIOR AREA OF BUILDING. 3458 W LAKE ST COMPLAINT FAILED View
ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. ALL CONDUIT, JUNCTION BOXES, DEVICES THROUGHOUT THE STORE AREA. (14E-1-110.12) 3458 W LAKE ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL EXTERIOR WALL BAY WINDOW LOOSE AND HANGING, RUSTED METAL SECTIONS. (DANGEROUS AND HAZARDOUS) 3458 W LAKE ST COMPLAINT FAILED View
FIRE EXTNGSHR RECHARGE & TAG FIRE EXTINGUISHERS ALL MISSING AND OR OUTDATED TAGS. (DANGEROUS AND HAZARDOUS) 3458 W LAKE ST COMPLAINT FAILED View
TENANT ACCESS TO SERVICE TENANTS SHALL HAVE ACCESS TO THEIR PANELS AT ALL TIMES. PANELS FOR UNITS LOCATED IN STORE REAR AREA. 3458 W LAKE ST COMPLAINT FAILED View
PLASTIC TYPE EM LIGHTS AND EXIT SIGNS NOT APPROVED FOR USE. ONLY METAL TYPE EXIT SIGN AND EMERGENCY LIGHTS ARE APPROVED FOR USE. (14E-7-700.66C3) DANGEROUS AND HAZARDOUS CONDITION DUE TO NON-WORKING DEVICES. 3458 W LAKE ST COMPLAINT FAILED View
STAIRWELL ENCLOSURE - BASEMENT INTERIOR EVIDENCE AT 1ST FLOOR CEILING UNDERSIDE OF STAIRS EXPOSED WOOD MISSING FIRE PROTECTION. (DANGEROUS AND HAZARDOUS) 3458 W LAKE ST COMPLAINT FAILED View
INT WALL/CEILING CHIP PLASTER 1ST FLOOR CEILING WATER DAMAGED. 3458 W LAKE ST COMPLAINT FAILED View
PROVIDE OPEN FRONT TOILET SEAT ROUND TOILET WITH CLOSED FRONT SEAT AT EMPLOYEE BATHROOM. (18-29-420.3) 3458 W LAKE ST COMPLAINT FAILED View
FIRE EXTNGSHR REQ, RESDNTL FIRE EXTINGUISHERS NOT INSTALLED, SITTING ON FLOOR IN CORNER. (DANGEROUS AND HAZARDOUS) 3458 W LAKE ST COMPLAINT FAILED View
LISTED FOR USE TEMP & LOCATION PROVIDE WEATHERPROOF BOXES, LIGHTS, FITTINGS AND APPROVED RACEWAY IN WALK-IN COOLER AREAS. 3458 W LAKE ST COMPLAINT FAILED View
PROVIDE A WATER MAIN GROUND CONDUIT, CONDUCTOR TO WITHIN 5 FT. OF WATER METER OR VALVE. (14E-2-250.68C1) 3458 W LAKE ST COMPLAINT FAILED View
PROVIDE 1ST FLOOR CEILING EXPOSED JOIST MISSING SECTIONS OF PLASTER. COMPROMISED FIRE SEPARATION. (13-56-28) (DANGEROUS AND HAZARDOUS) 3458 W LAKE ST COMPLAINT FAILED View
ADD RECEPTACLES ADD RECEPTACLES TO EASE EXTENSION CORD USE THROUGHOUT THE CEILING AREA AND STORE AREAS. (DANGEROUS AND HAZARDOUS CONDITION) 3458 W LAKE ST COMPLAINT FAILED View
PROVIDE INTERIOR PLATFORM AT CASHIER UNKNOWN FIRE RATING. (15-8-570) 3458 W LAKE ST COMPLAINT FAILED View
THE LIGHT FIXTURES HAVE BEEN ALTERED WITH UNKNOWN PARTS AND WITHOUT PERMITS. (14E-1-110.3) 3458 W LAKE ST COMPLAINT FAILED View
SUBMIT PLANS FOR PLUMBING PRMT SPECIFICALLY BATHROOM, KITCHEN AND MECHANICAL ROOM WASTE, DRAINAGE, VENT AND WATER PIPING WERE ALL CONSTRUCTED WITHOUT PLANS OR PERMITS. 3458 W LAKE ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO 1ST FLOOR OR RESTORE THE BUILDING TO THE ORIGINAL STATE. INCLUDE ALL STRUCTURAL REPAIR IN PLANS AND PERMIT. 3458 W LAKE ST COMPLAINT FAILED View
CEILING SUPPORT WIRES AND CEILING GRIDS SHALL NOT BE USED FOR SUPPORT. THERE ARE CONDUIT, JUNCTION BOXES THROUGHOUT THE ABOVE DROP CEILING AREAS AND THROUGHOUT STORE AREA THAT ARE NOT PROPERLY SUPPORTED. THERE ARE LIGHT FIXTURES THROUGHOUT THE STORE AREA NOT PROPERLY SUPPORTED. (DANGEROUS AND HAZARDOUS CONDITION) (14E-3-300.11) 3458 W LAKE ST COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY REAR EXIT OBSTRUCTED BLOCKED AND DOOR UNABLE TO OPEN DOOR. (DANGEROUS AND HAZARDOUS) 3458 W LAKE ST COMPLAINT FAILED View
WORKING SPACE PROVIDE PROPER CLEARANCES FOR ELECTRICAL PANEL AND DISCONNECTS OBSTRUCTED BY WALL AND DEBRIS. DANGEROUS AND HAZARDOUS CONDITION DUE TO NOT READILY ACCESSIBLE. 3458 W LAKE ST COMPLAINT FAILED View
CARB MONOX DETECT IN RESID MISSING WORKING CARBON MONOXIDE DETECTORS. (DANGEROUS AND HAZARDOUS) 3458 W LAKE ST COMPLAINT FAILED View
PROVIDE THE REQUIRED DIAGRAM AND LOAD CALCULATIONS FOR FEEDERS, SERVICES AND REQUIRED EQUIPMENT. (14E-2-215.5, 14E-2-220.5) 3458 W LAKE ST COMPLAINT FAILED View
SUBMIT STRUCT. ENG. RPT (INT.) STRUCTURE INTERIOR 1ST FLOOR CEILING JOIST OVER NOTCHED AND SECTION OF WALL REMOVED AND HANGING FROM CEILING. PROVIDE PLANS AND PERMIT FOR REPAIR WITH STRUCTURAL ENGINEER'S REPORT. (DANGEROUS AND HAZARDOUS) 3458 W LAKE ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTORS. (DANGEROUS AND HAZARDOUS) 3458 W LAKE ST COMPLAINT FAILED View
REPLACE DEFECTIVE VALVE,PIPING 4" CAST IRON SANITARY PIPE AT EAST WALL NEXT TO MEAT COUNTER IS MISSING SUPPORT ON VERTICAL AND HORIZONTAL RUNS. PIPE IS LEANING AND AT RISK OF FALLING. (DANGEROUS AND HAZARDOUS) (18-29-102.3) 3458 W LAKE ST COMPLAINT FAILED View
OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS. (13-12-360) 3458 W LAKE ST COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE UNAPPROVED FLEXIBLE WATER SUPPLIES TO ALL PLUMBING FIXTURES. (18-29-605) 3458 W LAKE ST COMPLAINT FAILED View
WORK NOT ALLOWED EVIDENCE OF ALTERATIONS AT 1ST FLOOR STORE - WALLS REMOVED AND INSTALLED, ELEVATED PLATFORM INSTALLED, ELEVATED OFFICE INSTALLED, EXITS COMPROMISED. REMOVE ALL PARTITIONS AND FIXTURES INCLUDING PLUMBING AND ELECTRIC INSTALLED ON THE 1ST FLOOR WITHOUT A PERMIT. 3458 W LAKE ST COMPLAINT FAILED View
INSTALL COVERS PROVIDE PROPER TYPE COVERS FOR OPEN WIRING AT LIGHT FIXTURES. (DANGEROUS AND HAZARDOUS CONDITION) 3458 W LAKE ST COMPLAINT FAILED View
ENGAG LIC & BOND PLMBNG CNTRC ENGAGE LICENSED AND BONDED PLUMBING CONTRACTOR TO INSTALL PLUMBING. 3458 W LAKE ST COMPLAINT FAILED View
PROVIDE AISLES RESTRICTIONS THROUGHOUT: 26", 30", 33". ALL BELOW 36". (DANGEROUS AND HAZARDOUS) (15-4-880, 15-4-900) 3458 W LAKE ST COMPLAINT FAILED View
SPLICE IN CORD REMOVE UNAPPROVED CORD SPLICE TO APPLIANCES IN KITCHEN AREA, AND COOLER AREAS. (DANGEROUS AND HAZARDOUS CONDITION) 3458 W LAKE ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION 2ND 3RD AND REAR PORCH NO ENTRY 3458 W LAKE ST PERIODIC FAILED View