The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPLACE D&H PORCH | (SPECIAL) SOUTHWEST/SOUTHEAST PORCHES - COLUMNS ARE RESTED ON CONCRETE, FOUNDATION STATUS IS UNKNOWN, COLUMNS ARE OUT OF PLUMB, TWISTED AND SEPARATING AT THE SPLICE. UNDERSIZED JOISTS (2X8) FOR A 12 FOOT SPAN AND MISSING BRIDGING. LOOSE BUCKLED AND WORN TREADS. LOOSE HAND AND GUARDRAILS. BROKEN GUARDRAIL AT 1ST LANDING. SYSTEM SWAYS NOTICEABLY UPON LOAD. IMPROPER CONNECTIONS - MOST MEMBERS ARE TOE NAILED TOGETHER AND ARE SEPARATED AT THE CONNECTIONS. PLANS AND PERMIT REQUIRED FOR REPLACEMENT OF BOTH SYSTEMS. SIGNS POSTED FOR DANGEROUS AND HAZARDOUS. | 5912 W WASHINGTON BLVD | PERIODIC | PASSED | View |
REPAIR PORCH SYSTEM | NORTHWEST/NORTHEAST PORCHES - COLUMNS ARE RESTED ON CONCRETE, FOUNDATION STATUS IS UNKNOWN. LOOSE HAND AND GUARDRAIL. BROKEN AND MISSING PICKETS. LOOSE, WORN TREADS AND RISERS. GUARDRAILS ARE ONLY 35 INCHES IN HEIGHT. IMPROPER CONNECTIONS - MOST MEMBERS ARE TOE NAILED AND ARE SEPARATED AT THE CONNECTIONS. PLANS AND PERMIT REQUIRED FOR REPAIRS OR REPLACEMENT. | 5912 W WASHINGTON BLVD | PERIODIC | PASSED | View |
REPAIR EXTERIOR WALL | EAST AT REAR - ERODED MORTAR. | 5912 W WASHINGTON BLVD | PERIODIC | FAILED | View |
CHIMNEY | NORTH CHIMNEY - ERODED MORTAR. | 5912 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR SCREENS | BUILDING - NUMEROUS TORN AND MISSING. | 5912 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REMOVE STAGNANT WATER BSMT | EAST AT REAR - STANDING SEWER WATER. | 5912 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPLACE DEFECTIVE WASTE PIPING | EAST AT REAR - BROKEN DRAIN PIPE. | 5912 W WASHINGTON BLVD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR - NO RESPONSE MOST APARTMENTS, UNVERIFIED DETECTORS. | 5912 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 5916 FRONT STAIRWAY - DETECTOR IS OUT OF SERVICE AND HANGING BY THE WIRES. | 5912 W WASHINGTON BLVD | PERIODIC | FAILED | View |
ADDITIONAL EXIT | SR#802215007- 5912-5914 REAR MISSING EGRESS PORCHES REMOVED BEING REBUILT NO EGRESS AT REAR 5912-5914 | 5912 W WASHINGTON BLVD | PERIODIC | PASSED | View |
REPAIR EXTERIOR DOOR SILL | 5912 APARTMENT 301 FRONT ENTRY DOOR BROKEN CLOSING DEVICE | 5912 W WASHINGTON BLVD | PERIODIC | PASSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR TO INSPECT DETECTORS IN APARTMENTS AND STAIRWAYS | 5912 W WASHINGTON BLVD | PERIODIC | PASSED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO VERIFY DETECTORS, OCCUPANCY, INSPECT REAR PORCHES, FRONT STAIRWAY | 5912 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | NORTH ELEVATION 2ND FLR 2 BROKEN WINDOW PANES. | 5912 W WASHINGTON BLVD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO GAIN ENTRY TO VERIFY OCCUPANCY AND DETECTORS. | 5912 W WASHINGTON BLVD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO GAIN ENTRY TO VERIFY OCCUPANCY AND DETECTORS.[FOR ANNUAL INSPECTION] | 5912 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | COURT YARD WINDOW SILLS; OPEN JOINTS. | 5912 W WASHINGTON BLVD | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | WEST SERVICE WALK; BROKEN CONCRETE. | 5912 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR AREAWAY WALL | 5918 BASEMENT RETAINING WALL; BROKEN CONCRETE. | 5912 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | BASEMENT LAUNDRY ROOM CEILING DRYWALL; BROKEN. | 5912 W WASHINGTON BLVD | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | SOUTH AREAWAY DOORS; BOARDED UP. | 5912 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR AREAWAY WALL | 5918 BASEMENT RETAINING WALL; BROKEN CONCRETE. | 5912 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR SCREENS | WINDOW SCREENS; TORN. | 5912 W WASHINGTON BLVD | PERIODIC | FAILED | View |