Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | THROUGH OUT INTERIOR CONCRETE STRUCTURE SPALLING LOOSE FALLEN SECTIONS EXPOSED RUSTED REBAR THROUGH OUT PARKING GARAGE PLANS AND PERMIT REQUIRED FOR REPAIRS OF BUILDING STRUCTURE | 211 W LAKE ST | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | ROOF TOP STORAGE BUILDING- BROKEN WINDOWS. | 211 W LAKE ST | PERIODIC | FAILED | View |
PROVIDE SIDEWALK SHED F/PROTCT | PROVIDE A CANOPY ALONG BOTH ELEVATIONS TO PROTECT THE ALLEY AND THE FRONT OF THE BUILDING | 211 W LAKE ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | REPAIR EXTERIOR WALL - (1) NORTH ELEVATION BRICKS HAVE FALLEN OVER NORTHWEST GARAGE DOOR ENTRANCE DANGEROUS AND HAZARDOUS, MANY LOOSE BRICKS AND SEVERE WASHED OUT MORTAR, AT NORTHEAST GARAGE DOOR ENTRANCE THERE IS A SEVERE DEFLECTION AT THE GARAGE DOOR HEADER DANGEROUS AND HAZARDOUS, AT BOTH DOORS THE SIDING AND WOOD IS SEVERELY DAMAGED AND ROTTED (2) ALL SIDING ALONG THE NORTH ELEVATION MUST BE REMOVED TO OBSEREVED SEVERITY OF DANGEROUS AND HAZARDOUS CONDITIONS (3) SOUTH ELEVATION DANGEROUS AND HAZARDOUS CONDITIONS AT PARAPET WALLS SEVERE WASHED OUT MORTAR, AT THE FIRE ESCAPE CONNECTION POINTS THE WALL HAS BULGED IMMENSELY PLACING THE FIRE ESCAPE IN A DANGEROUS CONDITION OF USE, THERE IS A LARGE BULGE ALSO OPPISITE OF THE FIRE ESCAPE AT THE SECOND FLOOR, THERE IS SPALLING OF THE CONCRETE PATCHING, BRICK AND SEVERE WASHED OUT MORTAR (4) AT TOP OF GARAGE PENTHOUSES SEVERE BRICK AND CONCRETE DAMAGE, SPALLING, LOOSE BRICKS, STRUCTURAL CRACKS AREAS ARE OPEN TO PUBLIC AND CONSIDERED DANGEROUS AND HAZARDOUS (5) PLANS AND PERMITS ARE REQUIRED FOR ALL REPAIRS | 211 W LAKE ST | PERIODIC | FAILED | View |
SUBMIT 2 COPY STRUCTURAL RPT | PROVIDE STRUCTURAL ENGINEERS REPORT FOR (1) ALL EXTERIOR AND INTERIOR WALLS, FLOORS AND CEILINGS, 100% OF BUILDING MUST BE INSPECTED (2) REPORT FOR ALL PARKING GARAGE FLOOR LOADS (3) SUBMIT REPORT TO JOSE APARICIO, 120 N. RACINE, 60607 | 211 W LAKE ST | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | INTERIOR WALLS AND CEILINGS - (1) CONCRETE CEILINGS SEVERE SPALLING AND RUSTING OF THE REBAR AND STEEL (2) AT ALL LEVELS IMMENSE WATER INFILTRATION CAUSING STALACTITES AND DAMAGE TO CONCRETE AND INTERIOR WALLS (3) ALL ELEVATIONS SEVERE WASHED OUT MORTAR (4) FLOORS CONCRETE IS CRACKING AND BROKEN AT VARIOUS AREAS (5) PLANS AND PERMITS FOR ALL REPAIRS IS REQUIRED | 211 W LAKE ST | PERIODIC | FAILED | View |
SUBMIT ARCHITECTURAL PLANS | SUBMIT PLANS AND PERMITS FOR ALL FLOOR LOADS AND PROPER REPAIRS TO PARKING FLOORS | 211 W LAKE ST | PERIODIC | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 211 W LAKE ST | PERIODIC | PASSED | View | |
MAINTAIN MECH. VENT SYSTEM | MAINTAIN MECHANICAL VENTILATION SYSTEM IN GOOD REPAIR (18-28-102.3) REMOVE ALL ABANDON MAKEUP AIR UNIT IN PARKING GARAGE, POTENTIALLY HAZARDOUS CONDITION OVER TIME THAT COULD RESULT IN THE UNITS COLLAPSING ONTO VARIOUS CARS | 211 W LAKE ST | PERIODIC | PASSED | View |
REPAIR DOOR HARDWARE | FRONT INTERIOR DOORS ON STAIRS DO NOT LATCH | 211 W LAKE ST | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | AT FRONT RESTAURANT, EXIT THRU DOUBLE KEYED DOOR, BOLTED DOOR AT 3RD FLOOR DOOR BOLTED ON INSIDE | 211 W LAKE ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | AT INTERIOR OF PARKING GARAGE ON ALL ELEVATIONS, MUCH LOOSE CEMENT COATING, MISSING CEMENT EXPOSING REBARS, MANY AREAS WITH STRESS CRACKS ON BEAMS | 211 W LAKE ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS & PERMITS | 211 W LAKE ST | COMPLAINT | FAILED | View |
OBTAIN PERMIT BEFORE SIGN WORK | SIGN READS' EARLY BIRD SPECIAL-FLAT VINYL SIGN APPROXIMATE SIZE' 12'X 8' 13-20-520 | 211 W LAKE ST | COMPLAINT | FAILED | View |
SUBMIT 2 COPY STRUCTURAL RPT | PROVIDE STUCTUAL ENGINEERS REPORT ON ENTIRE BUILDING PARKING GARAGE STRUCTUAL INTERITY BUILDING IS IN BAD SHAPE AND NEED OF MAJOR REPAIRS | 211 W LAKE ST | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | OFFICE EXIT SIGN NOT ILLUMINATED | 211 W LAKE ST | PERIODIC | FAILED | View |
FLOOR LOAD CARDS | POST PROPER FLOOR LOAD CARDS ON ALL FLOOR LEVELS | 211 W LAKE ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | AT TOP FLOOR OLD WOOD DOORS PROVIDING ACCESS TO ROOF TOP PARKING LEVEL SEVERLY ROTTED, DAMAGED GLASS LITES BROKEN | 211 W LAKE ST | PERIODIC | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 211 W LAKE ST | PERMIT | PASSED | View |