Last Modification Date: 2024-10-24 @ 5:23 PM
PIN: 20223110010000
Property Address: 6801 S CALUMET AVE
City - Zip: CHICAGO - 60637
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70030
2023 Tax District: 70001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 16 Violations
Violation Inspector Comments Address Category Status View
FLAKY INTERIOR PAINT WEST ELEVATION AND NORTH ELEVATION, WINDOW FRAMES FLAKING PAINT. 6801 S CALUMET AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL NORTH ELEVATION BASEMENT LEVEL OPEN MORTAR JOINTS AND CRACKED BRICKS. 6801 S CALUMET AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR PLANS - PERMIT ARE REQUIRED FOR REPAIRS AND PORCH SYSTEMS. 6801 S CALUMET AVE COMPLAINT FAILED View
INT WALL/CEILING PEELING PAINT TUB FLAKY FINISH 6801 S CALUMET AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM FRONT STAIRS GRADE TO 1 HANDRAIL LOOSE 6801 S CALUMET AVE COMPLAINT FAILED View
CEILING HEIGHT 7FT EXIST BLDGS SKYLIGHT WATER DAMAGED PLASTER 6801 S CALUMET AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH IMPROPER SPLICE ROTTEN UNDERSIZED DECK AT 2 BEAM AND STRINGER NOT ANCHORED PERMIT ONLY NO PLANS TO REPAIR PORCH 6801 S CALUMET AVE COMPLAINT FAILED View
MICE/RODENTS 6801 S. CALUMET 1ST FLOOR APT. EVIDENCE OF RODENTS. 6801 S CALUMET AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH, FOUNDATIONS MISSING/COLUMNS RESTING ON GROUND. LEDGERS MISSING BOLTS, JOIST MISSING HANGERS, BEAM COLUMN CONNECTIONS MISSING BOLTS, COLUMN 1/2 LAP JOINTS MISSING BOLTS, GUARDRAILS BELOW 42", EXCESSIVE GAP BETWEEN STAIR STRINGERS AND BUILDING, PLYWOOD UNDER 2ND LEVEL DECKING ROTTING AND WATER DAMAGED. 6801 S CALUMET AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING - MISSING OWNER'S ID. SIGN. 6801 S CALUMET AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE, UNABLE TO VERIFY DETECTORS AND INTERIOR CONDITIONS. 6801 S CALUMET AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL NORTH ELEVATION - VERTICAL AND STEP CRACKS.SOUTH ELEVATION - WASHED OUT MORTAR AND SPALLING BRICKS (EAST END). 6801 S CALUMET AVE COMPLAINT FAILED View
SCREEN OUTER DOORS, WINDOWS ALL ELEVATIONS - MISSING WINDOW AND DOOR SCREENS. 6801 S CALUMET AVE COMPLAINT FAILED View
STOP/REMOVE NUISANCE REAR BASEMENT AREAWAY - DISCARDED STOVE. 6801 S CALUMET AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR 2 STORY PORCH: COLUMNS ERECTED ON TOP OF CONCRETE BASES, FOUNDATION STATUS UNKNOWN.; LANDING HEADER - SAGGING.; NORTH COLUMN ROTTED, SOUTH COLUMN IS STACKED ON TOP OF BEAM AND FASTENED WITH METAL TIE STRAP.; RIM JOIST, STRINGERS, RAILING HORIZONTAL TIES ARE FASTENED WITH NAILS ONLY.; RIM JOIST NOTCH IS 6" AWAY FROM BEAM FIRE CUT.; RAILING LOOSE AND PULLING.; UNDERSIZED 6"X6" BEAMS SPAN 6'-5".; UNDERSIZED 2"X8" DECK JOIST SPAN - 10'-2".; TREADS ARE ONLY 9-1/4" DEEP. PLANS AND PERMIT ARE REQUIRED FOR PORCH REPAIRS. 6801 S CALUMET AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS SEVERAL WINDOWS ARE BOARDED UP. 6801 S CALUMET AVE COMPLAINT FAILED View