Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
FLAKY INTERIOR PAINT | WEST ELEVATION AND NORTH ELEVATION, WINDOW FRAMES FLAKING PAINT. | 6801 S CALUMET AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION BASEMENT LEVEL OPEN MORTAR JOINTS AND CRACKED BRICKS. | 6801 S CALUMET AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS - PERMIT ARE REQUIRED FOR REPAIRS AND PORCH SYSTEMS. | 6801 S CALUMET AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | TUB FLAKY FINISH | 6801 S CALUMET AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT STAIRS GRADE TO 1 HANDRAIL LOOSE | 6801 S CALUMET AVE | COMPLAINT | FAILED | View |
CEILING HEIGHT 7FT EXIST BLDGS | SKYLIGHT WATER DAMAGED PLASTER | 6801 S CALUMET AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH IMPROPER SPLICE ROTTEN UNDERSIZED DECK AT 2 BEAM AND STRINGER NOT ANCHORED PERMIT ONLY NO PLANS TO REPAIR PORCH | 6801 S CALUMET AVE | COMPLAINT | FAILED | View |
MICE/RODENTS | 6801 S. CALUMET 1ST FLOOR APT. EVIDENCE OF RODENTS. | 6801 S CALUMET AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH, FOUNDATIONS MISSING/COLUMNS RESTING ON GROUND. LEDGERS MISSING BOLTS, JOIST MISSING HANGERS, BEAM COLUMN CONNECTIONS MISSING BOLTS, COLUMN 1/2 LAP JOINTS MISSING BOLTS, GUARDRAILS BELOW 42", EXCESSIVE GAP BETWEEN STAIR STRINGERS AND BUILDING, PLYWOOD UNDER 2ND LEVEL DECKING ROTTING AND WATER DAMAGED. | 6801 S CALUMET AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - MISSING OWNER'S ID. SIGN. | 6801 S CALUMET AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNABLE TO VERIFY DETECTORS AND INTERIOR CONDITIONS. | 6801 S CALUMET AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION - VERTICAL AND STEP CRACKS.SOUTH ELEVATION - WASHED OUT MORTAR AND SPALLING BRICKS (EAST END). | 6801 S CALUMET AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS - MISSING WINDOW AND DOOR SCREENS. | 6801 S CALUMET AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR BASEMENT AREAWAY - DISCARDED STOVE. | 6801 S CALUMET AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 2 STORY PORCH: COLUMNS ERECTED ON TOP OF CONCRETE BASES, FOUNDATION STATUS UNKNOWN.; LANDING HEADER - SAGGING.; NORTH COLUMN ROTTED, SOUTH COLUMN IS STACKED ON TOP OF BEAM AND FASTENED WITH METAL TIE STRAP.; RIM JOIST, STRINGERS, RAILING HORIZONTAL TIES ARE FASTENED WITH NAILS ONLY.; RIM JOIST NOTCH IS 6" AWAY FROM BEAM FIRE CUT.; RAILING LOOSE AND PULLING.; UNDERSIZED 6"X6" BEAMS SPAN 6'-5".; UNDERSIZED 2"X8" DECK JOIST SPAN - 10'-2".; TREADS ARE ONLY 9-1/4" DEEP. PLANS AND PERMIT ARE REQUIRED FOR PORCH REPAIRS. | 6801 S CALUMET AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SEVERAL WINDOWS ARE BOARDED UP. | 6801 S CALUMET AVE | COMPLAINT | FAILED | View |