Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-26 @ 1:38 AM
PIN: 20081040400000
Property Address: 4746 S ADA ST
City - Zip: CHICAGO - 60609
2023 Property Class: 211
2023 Township: 72 - Lake
2023 Neighborhood: 72051
2023 Tax District: 72018
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 59 Violations
Violation Inspector Comments Address Category Status View
WORK NOT ALLOWED PORTIONS OF REAR PORCH HAVE BEEN ENCLOSED AND REMODELED INTO LIVING SPACE. REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED AT THE REAR PORCH WITHOUT A PERMIT. 4746 S ADA ST COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR 1)SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO THE REAR PORCH OR RESTORE THE BUILDING TO THE ORIGINAL STATE.2) WEST ELEVATION / TWO STORY FRAME ADDITION BUILT ADJACENT TO ENCLOSED PORCH, NO PERMIT OBTAINED. PLANS AND PERMIT ARE NOW REQUIRED. SUBJECT TO FIELD INSPECTION AND APPRVAL BY ALL RELATED TRADES. 4746 S ADA ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM WEST ELEVATION / THREE STORY ENCLOSED WOOD PORCH - 6X6 POSTS ON CONCRETE PIERS, FOUNDATION STATUS UNKNOWN. 6X6 BEAMS PULLING FROM 6X6 POSTS AT MULTIPLE LOCATIONS. FRAMING MEMBERS THROUGHOUT NOT VISIBLE DUE TO PARITITIONS. LOOSE AND PULLING RAILING SYSTEM THROUGHOUT. RAILING SYSTEM THROUGHOUT AT INSUFFICIENT HEIGHT. UPPER AND LOWER ENDS OF STAIR STRINGER INADEQUATELY ANCHORED TO POSTS/BEAMS WITH NAILS ONLY. STAIR FLIGHTS SLOPING THROUGHOUT. EGRESS OF ORIGINAL 3 STORY PORCH MODIFIED TO TRAVEL THROUGH TWO STORY ADDITION. REPAIRS MADE UNDER PERMIT #100615710 ARE OF SUBSTANDARD WORKMANSHIP AND ONLY ADDRESS STAIR FLIGHTS AT SECOND AND THIRD FLOORS.PLANS AND PERMIT REQUIRED FOR REPLACEMENT OF THREE STORY WOOD PORCH. 4746 S ADA ST COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS WEST ELEVATION / ATTIC - MISSING WINDOW. 4746 S ADA ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING,NO OWNERS I D SIGN POSTED. 4746 S ADA ST COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED WEST ELEVATION,BRICK GARAGE,NORTH WALL BUCKLING BRICK,FRACTURED MASONRY,WEST MISSING BRICKS AT GRADE,COPPING TILES,BROKEN TILES. 4746 S ADA ST COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY FRONT AND REAR GATES,PAD LOCKED. 4746 S ADA ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION BUILDING NO ENTRY TO CHECK OCCUPANCY,DETECTORS AND COMPLAINT OF BASEMENT UNIT FLOOR BROKEN TILE,LARGE HOLE. 4746 S ADA ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM EAST ELEVATION,FRONT PORCH,6 BY 6 SET ON CONCRETE BLOCKS,FOUNDATION STATUS UNKNOWN,LEDGER BOARD FACE NAILED ONLY.JOISTS ARE FACE NAILED ONLY,STAIR STRINGERS ARE TOE NAILED AT TOP CONNECTION,OVER NOTCHED,TREADS HAVE NAILS POPPING,NORTH RAIL IS LOOSE AND PULLING.PERMIT REQUIRED FOR REPAIRS. 4746 S ADA ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR ENCLOSED PORCH GRADE TO ATTIC,FOUNDATION STATUS UNKNOWN,JOISTS ARE 2 BY 4 AT 1ST FLOOR LANDING,2 BY 6 JOIST SPAN 10' 8'' FACE NAILED ONLY,BEAMS ARE TOE NAILED ONLY,PULLING AWAY FROM SUPPORTS,COULMNS ARE BUTT JOINTED,RAILS ARE LADDER TYPE LOOSE AND PULLING,STRINGERS ARE FACE NAILED ONLY AT TOP CONNECTION,TREADS ARE WORN,DECKING BOARDS ARE ROTTED.PLANS AND PERMIT REQUIRED FOR REPAIRS OR REPLACEMENT. 4746 S ADA ST COMPLAINT FAILED View
CONNECT GAS APPLIANCE TO VENT NORTH ELEVATION / ENCLOSED PORCH / GAS FIRED WATER HEATER VENT - NOT EXTENDED ABOVE ROOF LINE. 4746 S ADA ST COMPLAINT PASSED View
CARB MONOX DETECT IN RESID 2ND FLOOR UNIT,MISSING CARBON MONOXIDE DETECTOR. 4746 S ADA ST COMPLAINT FAILED View
CARB MONOX DETECT IN RESID ATTIC / CARBON MONOXIDE DETECTOR - MISSING.ENCLOSED PORCH / ADJACENT TO HOT WATER HEATERS AT GRADE LEVEL / CARBON MONOXIDE DETECTOR - MISSING. 4746 S ADA ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS TOP OF ENCLOSED PORCH / SMOKE DETECTOR - MISSINGATTIC / SMOKE DETECTOR - MISSING. 4746 S ADA ST COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY REAR YARD / GATE ADJACENT TO PUBLIC ALLEY - CHAINED AND PADLOCKED. 4746 S ADA ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL EAST ELEVATION / EXTERIOR WALL / ADJACENT TO LEDGER FOR STAIR SYSTEM - FRACTURED MASONRY WITH WASHED OUT MORTAR. 4746 S ADA ST COMPLAINT FAILED View
REPAIR DOWNSPOUT EAST ELEVATION / DOWNSPOUT - MISSING SECTIONS NEAR GRADE. 4746 S ADA ST COMPLAINT FAILED View
CONNECT GAS APPLIANCE TO VENT NORTH ELEVATION / ENCLOSED PORCH / GAS FIRED WATER HEATER VENT - NOT EXTENDED ABOVE ROOF LINE. 4746 S ADA ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM EAST ELEVATION / STAIRS FROM GRADE TO SECOND FLOOR - LOOSE AND RUSTING METAL RAILINGS. 4746 S ADA ST COMPLAINT FAILED View
WORK CONTRARY TO PERMIT EAST ELEVATION / STAIRS FROM GRADE TO SECOND FLOOR - PERMIT #100433040 ISSUED 03/26/12 SPECIFIES REPAIRS TO PORCH ONLY. NEWLY BUILT FRONT PORCH EXCEEDS SCOPE OF WORK ON PERMIT. 4746 S ADA ST COMPLAINT FAILED View
REPAIR DOWNSPOUT EAST ELEVATION / DOWNSPOUT - MISSING SECTIONS NEAR GRADE. 4746 S ADA ST COMPLAINT PASSED View
OBSTRUCTIONS IN EXIT WAY REAR YARD / GATE ADJACENT TO PUBLIC ALLEY - CHAINED AND PADLOCKED. 4746 S ADA ST COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING, NO ENTRY TO GROUND FLOOR AND THIRD FLOOR APARTMENTS. UNABLE TO VERIFY DETECTORS AND CONDITIONS. 4746 S ADA ST COMPLAINT PASSED View
CARB MONOX DETECT IN RESID ATTIC / CARBON MONOXIDE DETECTOR - MISSING.ENCLOSED PORCH / ADJACENT TO HOT WATER HEATERS AT GRADE LEVEL / CARBON MONOXIDE DETECTOR - MISSING. 4746 S ADA ST COMPLAINT PASSED View
INSTALL SMOKE DETECTORS TOP OF ENCLOSED PORCH / SMOKE DETECTOR - MISSINGATTIC / SMOKE DETECTOR - MISSING. 4746 S ADA ST COMPLAINT PASSED View
REPAIR EXTERIOR WALL EAST ELEVATION / EXTERIOR WALL / ADJACENT TO LEDGER FOR STAIR SYSTEM - FRACTURED MASONRY WITH WASHED OUT MORTAR. 4746 S ADA ST COMPLAINT PASSED View
WORK CONTRARY TO PERMIT EAST ELEVATION / STAIRS FROM GRADE TO SECOND FLOOR - PERMIT #100433040 ISSUED 03/26/12 SPECIFIES REPAIRS TO PORCH ONLY. NEWLY BUILT FRONT PORCH EXCEEDS SCOPE OF WORK ON PERMIT. 4746 S ADA ST COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR 1)SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO THE REAR PORCH OR RESTORE THE BUILDING TO THE ORIGINAL STATE.2) WEST ELEVATION / TWO STORY FRAME ADDITION BUILT ADJACENT TO ENCLOSED PORCH, NO PERMIT OBTAINED. PLANS AND PERMIT ARE NOW REQUIRED. SUBJECT TO FIELD INSPECTION AND APPRVAL BY ALL RELATED TRADES. 4746 S ADA ST COMPLAINT PASSED View
REPAIR PORCH SYSTEM EAST ELEVATION / STAIRS FROM GRADE TO SECOND FLOOR - LOOSE AND RUSTING METAL RAILINGS. 4746 S ADA ST COMPLAINT PASSED View
HEATING PLANT ENCLOSURE ATTIC / GAS FIRED HOT WATER HEATERS - MISSING FIRE RATED ENCLOSURE.ENCLOSED PORCH / GAS FIRED HOT WATER HEATERS - MISSING FIRE RATED ENCLOSURE. 4746 S ADA ST COMPLAINT PASSED View
REPAIR PORCH SYSTEM WEST ELEVATION / THREE STORY ENCLOSED WOOD PORCH - 6X6 POSTS ON CONCRETE PIERS, FOUNDATION STATUS UNKNOWN. 6X6 BEAMS PULLING FROM 6X6 POSTS AT MULTIPLE LOCATIONS. FRAMING MEMBERS THROUGHOUT NOT VISIBLE DUE TO PARITITIONS. LOOSE AND PULLING RAILING SYSTEM THROUGHOUT. RAILING SYSTEM THROUGHOUT AT INSUFFICIENT HEIGHT. UPPER AND LOWER ENDS OF STAIR STRINGER INADEQUATELY ANCHORED TO POSTS/BEAMS WITH NAILS ONLY. STAIR FLIGHTS SLOPING THROUGHOUT. EGRESS OF ORIGINAL 3 STORY PORCH MODIFIED TO TRAVEL THROUGH TWO STORY ADDITION. REPAIRS MADE UNDER PERMIT #100615710 ARE OF SUBSTANDARD WORKMANSHIP AND ONLY ADDRESS STAIR FLIGHTS AT SECOND AND THIRD FLOORS.PLANS AND PERMIT REQUIRED FOR REPLACEMENT OF THREE STORY WOOD PORCH. 4746 S ADA ST COMPLAINT PASSED View
REPLCE WINDOW PANES, PLEXGLAS WEST ELEVATION / ATTIC - MISSING WINDOW. 4746 S ADA ST COMPLAINT PASSED View
REPAIR PORCH SYSTEM STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; ORIGINAL METAL RAILS APPEARED TO HAVE BEEN RE-INSTALLED - HANDRAIL HEIGHT AT NOSING IS ONLY 33" AND RAIL HEIGHT IS ONLY 33 1/2". 4746 S ADA ST PERMIT PASSED View
REPAIR EXTERIOR WALL EXTERIOR WALL - ASPHALT SIDING - TORN, LOOSE; CRACKED, WASHED OUT MORTAR; SPALLING BRICKS 4746 S ADA ST COMPLAINT CLOSED View
STOP/REMOVE NUISANCE GRADE - LOVESEAT/COUCH UNDERNEATH FRONT STAIRS 4746 S ADA ST COMPLAINT CLOSED View
REPAIR DOWNSPOUT EAST ELEVATION,FRONT PORCH ROOF,MISSING DOWNSPOUT AT GRADE. 4746 S ADA ST COMPLAINT FAILED View
CONNECT GAS APPLIANCE TO VENT NORTH ELEVATION AT 1ST FLOOR,6'' METAL STOVE PIPE CHIMNEY STOPS AT 1ST FLOOR LEVEL.(NOT ABOVE ROOF LINE). 4746 S ADA ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL SOUTH ELEVATION,1ST FLOOR,TORN SIDING. 4746 S ADA ST COMPLAINT FAILED View
NO CLOSET/STORAGE UNDER STAIR REAR ENCLOSED PORCH,STORAGE SHED BUILT UNDER 1ST FLOOR STAIRS. 4746 S ADA ST COMPLAINT FAILED View
RATS REAR ENCLOSED PORCH AT GRADE,RAT HOLES. 4746 S ADA ST COMPLAINT FAILED View
INTERIOR FINISH FIRERESISTANCE FRONT INTERIOR STAIRS,WOOD PANELING ON WALLS. 4746 S ADA ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS FRONT INTERIOR STAIRS,2ND FLOOR UNIT,REAR ENCLOSED PORCH,MISSING SMOKE DETECTORS. 4746 S ADA ST COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING 2ND FLOOR UNIT,UNDER KITCHEN BASE CABINET,HOLES IN WALL. 4746 S ADA ST COMPLAINT FAILED View
STOP LEAKING WATER 2ND FLOOR KITCHEN SINK,LEAKING WATER. 4746 S ADA ST COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM FRONT STAIRS 1ST TO 2ND FLOOR,ROTTED BOARDS,LOOSE HAND RAILS. 4746 S ADA ST COMPLAINT FAILED View
REPAIR EXTERIOR DOOR HARDWARE FRONT ENTER DOOR MISSING DEAD BOLT LOCK. 4746 S ADA ST COMPLAINT FAILED View
REPAIR EXTERIOR DOOR, RESET FRONT ENTRY DOOR,LOOSE IN OPENING,WILL NOT CLOSE. 4746 S ADA ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION BUILDING NO ENTRY TO BASEMENT,1ST FLOOR UNIT TO CHECK COMPLAINT OF DISABLED PEOPLE LIVING IN DEPLORABLE CONDITIONS AND DEAD ANIMALS IN APARTMENT. 4746 S ADA ST COMPLAINT FAILED View
SCREEN OUTER DOORS, WINDOWS FRONT ELEVATION/ VARIOUS WINDOWS - MISSING SCREENS. 4746 S ADA ST COMPLAINT CLOSED View
REPAIR PORCH SYSTEM 4746 S ADA ST PERMIT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING, NO ENTRY TO GROUND FLOOR AND THIRD FLOOR APARTMENTS. UNABLE TO VERIFY DETECTORS AND CONDITIONS. 4746 S ADA ST COMPLAINT FAILED View
WORK NOT ALLOWED PORTIONS OF REAR PORCH HAVE BEEN ENCLOSED AND REMODELED INTO LIVING SPACE. REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED AT THE REAR PORCH WITHOUT A PERMIT. 4746 S ADA ST COMPLAINT FAILED View
REPAIR / REBUILD SHED GARAGE NORTH WALL BOWED OUTWARD AND SHEATHING ROTTED. 4746 S ADA ST COMPLAINT PASSED View
EXPOSED WIRING SOUTH ELEVATION AT 1ST FLOOR,EXPOSED WIRES.2ND FLOOR UNIT,OUTLETS MISSING COVERS. 4746 S ADA ST COMPLAINT FAILED View
REPAIR DOOR HARDWARE 2ND FLOOR UNIT FRONT DOOR MISSING LOCKSET,REAR DOOR MISSING DEAD BOLT LOCK. 4746 S ADA ST COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS WEST ELEVATION,ATTIC WINDOW,BOARDED. 4746 S ADA ST COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS FRONT ELEVATION/ GROUND FLOOR WINDOW - BROKEN PANE.ATTIC WINDOW - BOARDED UP WITH SIDING. 4746 S ADA ST COMPLAINT CLOSED View
HEATING PLANT ENCLOSURE ATTIC / GAS FIRED HOT WATER HEATERS - MISSING FIRE RATED ENCLOSURE.ENCLOSED PORCH / GAS FIRED HOT WATER HEATERS - MISSING FIRE RATED ENCLOSURE. 4746 S ADA ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO INTERIOR OF PROPERTY. 4746 S ADA ST COMPLAINT PASSED View