Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 10:23 PM
PIN: 16054140250000
Property Address: 1030 N PARKSIDE AVE
City - Zip: CHICAGO - 60651
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77013
2023 Tax District: 77001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 43 Violations
Violation Inspector Comments Address Category Status View
REPAIR EAVES FRONT BUILDING/ NORTH AND EAST ELEVATIONS/ ROOF EAVES - ROTTED WITH PEELING PAINT. 1030 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT BUILDING/ REAR 2-STORY WOOD PORCH/ COLUMNS ERECTED ON TOP OF CONCRETE BASES, FOUNDATION STATUS UNKNOWN. 4X6 COLUMNS - OVERNOTCHED AT RIM JOISTS CONNECTIONS. UNDERSIZED 4X6 BEAMS SPAN 7 FEET AND SIX INCHES AND ARE FASTENED TO BUILDING'S EXTERIOR WALL AND COLUMNS WITH SUBSTANDARD GAUGE METAL CONNECTORS. UNDERSIZED 2X8 RIM JOISTS SPAN 8 FEET AND 9 INCHES AND ARE ONLY NAILED TO COLUMNS. STRINGERS - ONLY NAILED TO COLUMNS AND BUILDING'S EXTERIOR WALL. TREADS - ONLY 9 AND 1/2 INCHES WIDE. RAILING SECTIONS ARE ONLY 31 INCHES HIGH, LOOSE AND PULLING.DECK BOARDS ARE BUCKLING UP.PLANS AND PERMIT REQUIRED TO REPAIR PORCH. 1030 N PARKSIDE AVE COMPLAINT FAILED View
ABANDONED REFRIGERATOR FRONT BUILDING REAR PORCH AT 1ST ABANDONED REFRIGERATOR DANGEROUS AND HAZARDOUS 1030 N PARKSIDE AVE COMPLAINT PASSED View
REPAIR EXTERIOR STAIR FRONT BUILDING REAR BASEMENT STAIRS DANGEROUS AND HAZARDOUS GRADE TO BASEMENT BROKEN AND COLLAPSING 1030 N PARKSIDE AVE COMPLAINT PASSED View
PROVIDE GUARD RAIL 42 IN HIGH FRONT BUILDING REAR BASEMENT STAIRWAY HAND AND GUARDRAILS MISSING 1030 N PARKSIDE AVE COMPLAINT PASSED View
FIRE DAMAGE, SINGED,SOOT REAR BUILDING NORTH WALL ROOF AND INTERIOR FIRE DAMAGED SOOTED AND CHARRED SHEATING FRAMING MEMBERS ROOF SHEATHING AND ROOFING MATERIAL PLANS AND PERMITS REQUIRED FOR ALL FIRE DAMAGE REPAIRS DANGEROUS AND HAZARDOUS 1030 N PARKSIDE AVE COMPLAINT PASSED View
NO KEY TO USE EXIT DOOR FRONT ENTRANCE GATE - DOUBLE KEY LOCK. 1030 N PARKSIDE AVE COMPLAINT PASSED View
REPLCE WINDOW PANES, PLEXGLAS FRONT BUILDING/SOUTH ELEVATION/ BASEMENT WINDOWS - BOARDED UP. 1030 N PARKSIDE AVE COMPLAINT PASSED View
CUT OR REMOVE HIGH WEEDS ALL ELEVATIONS - HIGH WEEDS AND OVERGROWN VEGETATION. FIRE HAZARD. 1030 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT BUILDING/ REAR 2-STORY WOOD PORCH/ COLUMNS ERECTED ON TOP OF CONCRETE BASES, FOUNDATION STATUS UNKNOWN. 4X6 COLUMNS - OVERNOTCHED AT RIM JOISTS CONNECTIONS. UNDERSIZED 4X6 BEAMS SPAN 7 FEET AND SIX INCHES AND ARE FASTENED TO BUILDING'S EXTERIOR WALL AND COLUMNS WITH SUBSTANDARD GAUGE METAL CONNECTORS. UNDERSIZED 2X8 RIM JOISTS SPAN 8 FEET AND 9 INCHES AND ARE ONLY NAILED TO COLUMNS. STRINGERS - ONLY NAILED TO COLUMNS AND BUILDING'S EXTERIOR WALL. TREADS - ONLY 9 AND 1/2 INCHES WIDE. RAILING SECTIONS ARE ONLY 31 INCHES HIGH, LOOSE AND PULLING.DECK BOARDS ARE BUCKLING UP.PLANS AND PERMIT REQUIRED TO REPAIR PORCH. 1030 N PARKSIDE AVE COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR FRONT BUILDING/ ATTIC HAS BEEN ALTERED INTO A 2ND FLOOR ADDITION WITHOUT PLANS AND PERMIT. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. 1030 N PARKSIDE AVE COMPLAINT PASSED View
REPAIR EAVES FRONT BUILDING/ NORTH AND EAST ELEVATIONS/ ROOF EAVES - ROTTED WITH PEELING PAINT. 1030 N PARKSIDE AVE COMPLAINT PASSED View
SCREEN OUTER DOORS, WINDOWS FRONT BUILDING/ ALL ELEVATIONS - MISSING SCREENS. 1030 N PARKSIDE AVE COMPLAINT PASSED View
CUT OR REMOVE HIGH WEEDS ALL ELEVATIONS - HIGH WEEDS AND OVERGROWN VEGETATION. FIRE HAZARD. 1030 N PARKSIDE AVE COMPLAINT PASSED View
REPAIR WINDOW SILLS REAR BUILDING, 1ST FLOOR, ROTTED SILL. 1030 N PARKSIDE AVE COMPLAINT FAILED View
PROVIDE GUTTER & DOWNSPOUT FRONT BUILDING, NORTH AND SOUTH ELEVATIONS, MISSING GUTTERS AND DOWNSPOUTS, REAR BUILDING WEST ELEVATION, MISSING DOWNSPOUT. 1030 N PARKSIDE AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS FRONT BUILDING WEST ELEVATION 1ST FLOOR,AND REAR BUILDING, WEST AND SOUTH ELEVATIONS, BROKEN PANES. 1030 N PARKSIDE AVE COMPLAINT FAILED View
MAINTAIN WINDOW REAR BUILDING, WEST ELEVATION, WINDOWS MISSING FRAME AND EXTERIOR TRIM. BL00831 1030 N PARKSIDE AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION FRONT AND REAR BUILDING, NO ENTRY TO VERIFY OCCUPANCY AND DETECTORS. 1030 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR WINDOW SILLS REAR BUILDING, 1ST FLOOR, ROTTED SILL. 1030 N PARKSIDE AVE COMPLAINT CLOSED View
LICENSED BONDED PLMBG CONTRCTR 1030 N PARKSIDE AVE COMPLAINT FAILED View
PROVIDE HOT WATER TO FIXTURES 1030 N PARKSIDE AVE COMPLAINT FAILED View
REPL DEFECTIVE BATHROOM FLOOR 1030 N PARKSIDE AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR FRONT BUILDING/ ATTIC HAS BEEN ALTERED INTO A 2ND FLOOR ADDITION WITHOUT PLANS AND PERMIT. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. 1030 N PARKSIDE AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS FRONT BUILDING/SOUTH ELEVATION/ BASEMENT WINDOWS - BOARDED UP. 1030 N PARKSIDE AVE COMPLAINT FAILED View
SCREEN OUTER DOORS, WINDOWS FRONT BUILDING/ ALL ELEVATIONS - MISSING SCREENS. 1030 N PARKSIDE AVE COMPLAINT FAILED View
CUT OR REMOVE HIGH WEEDS ALL ELEVATIONS - HIGH WEEDS AND OVERGROWN VEGETATION. FIRE HAZARD. 1030 N PARKSIDE AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING- NO OWNER'S ID SIGN POSTED. 1030 N PARKSIDE AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY FRONT BUILDING REAR PORCH AT 1ST-REFRIGERATOR AND DOOR LAYING ON DECK AND STAIRS HAMPERING EGRESS, DANGEROUS AND HAZARDOUS 1030 N PARKSIDE AVE COMPLAINT PASSED View
POST OWNER/MANAGERS NAME/# FRONT BUILDING/ OWNERS ID SIGN- MISSING. 1030 N PARKSIDE AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM FRONT BUILDING, TWO STORY REAR WOOD PORCH, HAS UNDERSIZED 4"X6" BEAMS AND 2"X8" RIM JOIST FOR 7'-6" AND 7'-10" SPAN, GUARDRAILS ARE 31" AND MISSING TOP SIDE RAIL, ALL CONNECTIONS SECURED WITH NAILS, PROVIDE PLAN AND PERMIT TO REPAIR PORCH. 1030 N PARKSIDE AVE COMPLAINT FAILED View
PROVIDE GUTTER & DOWNSPOUT FRONT BUILDING, NORTH AND SOUTH ELEVATIONS, MISSING GUTTERS AND DOWNSPOUTS, REAR BUILDING WEST ELEVATION, MISSING DOWNSPOUT. 1030 N PARKSIDE AVE COMPLAINT CLOSED View
REPLCE WINDOW PANES, PLEXGLAS FRONT BUILDING WEST ELEVATION 1ST FLOOR,AND REAR BUILDING, WEST AND SOUTH ELEVATIONS, BROKEN PANES. 1030 N PARKSIDE AVE COMPLAINT CLOSED View
MAINTAIN WINDOW REAR BUILDING, WEST ELEVATION, WINDOWS MISSING FRAME AND EXTERIOR TRIM. 1030 N PARKSIDE AVE COMPLAINT CLOSED View
ARRANGE PREMISE INSPECTION FRONT AND REAR BUILDING, NO ENTRY TO VERIFY OCCUPANCY AND DETECTORS. 1030 N PARKSIDE AVE COMPLAINT CLOSED View
REPAIR PORCH SYSTEM FRONT BUILDING, TWO STORY REAR PORCH, HAS UNDERSIZED 4"X6" BEAMS AND 2"X8" RIBBON JOIST FOR 7'-6" AND 7'-10" SPAN, GUARDRAILS ARE 31" AND MISSING TOP SIDE RAIL, ALL CONNECTIONS ARE FASTENED WITH NAILS ONLY, PROVIDE PLAN AND PERMIT TO REPAIR OR REPLACE PORCH. 1030 N PARKSIDE AVE COMPLAINT FAILED View
MAINTAIN WINDOW WEST AND SOUTH WINDOWS, SEVERAL WINDOWS, MISSING EXTERIOR ALUMINUM CAPPING. 1030 N PARKSIDE AVE COMPLAINT FAILED View
REPLACE D&H PORCH FRONT BUILDING/ REAR EXTERIOR 2 STORY PORCH/ COLUMNS- BEAMS AND RIM JOISTS NOTCHED IN AT SAME LOCATION. STAIR HEADER BEAM- WEAK AND SAGGING. UNDERSIZED 2X6 DECK JOISTS SPAN 12 FEET [WEAK AND SAGGING]. STRINGERS- SCABBED SECTIONS. STAIR SECTIONS- WEAK,SAGGING, AND COLLAPSING. RAILING SECTIONS ONLY 24 INCHES HIGH. PLANS AND PERMIT REQUIRED TO REPLACE: FRONT BUILDING- REAR EXTERIOR 2 STORY PORCH. 1030 N PARKSIDE AVE COMPLAINT PASSED View
FIRE DAMAGE, SINGED,SOOT REAR BUILDING SEVERELY FIRE DAMAGED. DEMOLITION PERMIT REQUIRED FOR REMOVAL. PLANS AND PERMITS REQUIRED FOR ALL REPAIRS, WITH ALL WORK PERFORMED SUBJECT TO FIELD INSPECTION, AND APPROVAL BY ALL RELATED TRADES. 1030 N PARKSIDE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT BUILDING, TWO STORY REAR WOOD PORCH, HAS UNDERSIZED 4"X6" BEAMS AND 2"X8" RIM JOIST FOR 7'-6" AND 7'-10" SPAN, GUARDRAILS ARE 31" AND MISSING TOP SIDE RAIL, ALL CONNECTIONS SECURED WITH NAILS, PROVIDE PLAN AND PERMIT TO REPAIR PORCH. 1030 N PARKSIDE AVE COMPLAINT CLOSED View
FIRE DAMAGE, SINGED,SOOT REAR BUILDING SEVERELY FIRE DAMAGED. DEMOLITION PERMIT REQUIRED FOR REMOVAL. PLANS AND PERMITS REQUIRED FOR ALL REPAIRS, WITH ALL WORK PERFORMED SUBJECT TO FIELD INSPECTION, AND APPROVAL BY ALL RELATED TRADES. 1030 N PARKSIDE AVE COMPLAINT PASSED View
ARRANGE FOR REINSPECTION REGAR FRONT AND REAR BUILDING, NO ENTRY TO VERIFY DETECTORS. 1030 N PARKSIDE AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS FRONT BUILDING/ EAST ELEVATION/ 1ST FLOOR WINDOW- BROKEN PANE. 1030 N PARKSIDE AVE COMPLAINT PASSED View