Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EAVES | FRONT BUILDING/ NORTH AND EAST ELEVATIONS/ ROOF EAVES - ROTTED WITH PEELING PAINT. | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT BUILDING/ REAR 2-STORY WOOD PORCH/ COLUMNS ERECTED ON TOP OF CONCRETE BASES, FOUNDATION STATUS UNKNOWN. 4X6 COLUMNS - OVERNOTCHED AT RIM JOISTS CONNECTIONS. UNDERSIZED 4X6 BEAMS SPAN 7 FEET AND SIX INCHES AND ARE FASTENED TO BUILDING'S EXTERIOR WALL AND COLUMNS WITH SUBSTANDARD GAUGE METAL CONNECTORS. UNDERSIZED 2X8 RIM JOISTS SPAN 8 FEET AND 9 INCHES AND ARE ONLY NAILED TO COLUMNS. STRINGERS - ONLY NAILED TO COLUMNS AND BUILDING'S EXTERIOR WALL. TREADS - ONLY 9 AND 1/2 INCHES WIDE. RAILING SECTIONS ARE ONLY 31 INCHES HIGH, LOOSE AND PULLING.DECK BOARDS ARE BUCKLING UP.PLANS AND PERMIT REQUIRED TO REPAIR PORCH. | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View |
ABANDONED REFRIGERATOR | FRONT BUILDING REAR PORCH AT 1ST ABANDONED REFRIGERATOR DANGEROUS AND HAZARDOUS | 1030 N PARKSIDE AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | FRONT BUILDING REAR BASEMENT STAIRS DANGEROUS AND HAZARDOUS GRADE TO BASEMENT BROKEN AND COLLAPSING | 1030 N PARKSIDE AVE | COMPLAINT | PASSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | FRONT BUILDING REAR BASEMENT STAIRWAY HAND AND GUARDRAILS MISSING | 1030 N PARKSIDE AVE | COMPLAINT | PASSED | View |
FIRE DAMAGE, SINGED,SOOT | REAR BUILDING NORTH WALL ROOF AND INTERIOR FIRE DAMAGED SOOTED AND CHARRED SHEATING FRAMING MEMBERS ROOF SHEATHING AND ROOFING MATERIAL PLANS AND PERMITS REQUIRED FOR ALL FIRE DAMAGE REPAIRS DANGEROUS AND HAZARDOUS | 1030 N PARKSIDE AVE | COMPLAINT | PASSED | View |
NO KEY TO USE EXIT DOOR | FRONT ENTRANCE GATE - DOUBLE KEY LOCK. | 1030 N PARKSIDE AVE | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | FRONT BUILDING/SOUTH ELEVATION/ BASEMENT WINDOWS - BOARDED UP. | 1030 N PARKSIDE AVE | COMPLAINT | PASSED | View |
CUT OR REMOVE HIGH WEEDS | ALL ELEVATIONS - HIGH WEEDS AND OVERGROWN VEGETATION. FIRE HAZARD. | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT BUILDING/ REAR 2-STORY WOOD PORCH/ COLUMNS ERECTED ON TOP OF CONCRETE BASES, FOUNDATION STATUS UNKNOWN. 4X6 COLUMNS - OVERNOTCHED AT RIM JOISTS CONNECTIONS. UNDERSIZED 4X6 BEAMS SPAN 7 FEET AND SIX INCHES AND ARE FASTENED TO BUILDING'S EXTERIOR WALL AND COLUMNS WITH SUBSTANDARD GAUGE METAL CONNECTORS. UNDERSIZED 2X8 RIM JOISTS SPAN 8 FEET AND 9 INCHES AND ARE ONLY NAILED TO COLUMNS. STRINGERS - ONLY NAILED TO COLUMNS AND BUILDING'S EXTERIOR WALL. TREADS - ONLY 9 AND 1/2 INCHES WIDE. RAILING SECTIONS ARE ONLY 31 INCHES HIGH, LOOSE AND PULLING.DECK BOARDS ARE BUCKLING UP.PLANS AND PERMIT REQUIRED TO REPAIR PORCH. | 1030 N PARKSIDE AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | FRONT BUILDING/ ATTIC HAS BEEN ALTERED INTO A 2ND FLOOR ADDITION WITHOUT PLANS AND PERMIT. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. | 1030 N PARKSIDE AVE | COMPLAINT | PASSED | View |
REPAIR EAVES | FRONT BUILDING/ NORTH AND EAST ELEVATIONS/ ROOF EAVES - ROTTED WITH PEELING PAINT. | 1030 N PARKSIDE AVE | COMPLAINT | PASSED | View |
SCREEN OUTER DOORS, WINDOWS | FRONT BUILDING/ ALL ELEVATIONS - MISSING SCREENS. | 1030 N PARKSIDE AVE | COMPLAINT | PASSED | View |
CUT OR REMOVE HIGH WEEDS | ALL ELEVATIONS - HIGH WEEDS AND OVERGROWN VEGETATION. FIRE HAZARD. | 1030 N PARKSIDE AVE | COMPLAINT | PASSED | View |
REPAIR WINDOW SILLS | REAR BUILDING, 1ST FLOOR, ROTTED SILL. | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | FRONT BUILDING, NORTH AND SOUTH ELEVATIONS, MISSING GUTTERS AND DOWNSPOUTS, REAR BUILDING WEST ELEVATION, MISSING DOWNSPOUT. | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | FRONT BUILDING WEST ELEVATION 1ST FLOOR,AND REAR BUILDING, WEST AND SOUTH ELEVATIONS, BROKEN PANES. | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | REAR BUILDING, WEST ELEVATION, WINDOWS MISSING FRAME AND EXTERIOR TRIM. BL00831 | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | FRONT AND REAR BUILDING, NO ENTRY TO VERIFY OCCUPANCY AND DETECTORS. | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | REAR BUILDING, 1ST FLOOR, ROTTED SILL. | 1030 N PARKSIDE AVE | COMPLAINT | CLOSED | View |
LICENSED BONDED PLMBG CONTRCTR | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View | |
PROVIDE HOT WATER TO FIXTURES | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View | |
REPL DEFECTIVE BATHROOM FLOOR | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View | |
PLANS & PERMITS REQ - CONTRCTR | FRONT BUILDING/ ATTIC HAS BEEN ALTERED INTO A 2ND FLOOR ADDITION WITHOUT PLANS AND PERMIT. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | FRONT BUILDING/SOUTH ELEVATION/ BASEMENT WINDOWS - BOARDED UP. | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | FRONT BUILDING/ ALL ELEVATIONS - MISSING SCREENS. | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | ALL ELEVATIONS - HIGH WEEDS AND OVERGROWN VEGETATION. FIRE HAZARD. | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING- NO OWNER'S ID SIGN POSTED. | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT BUILDING REAR PORCH AT 1ST-REFRIGERATOR AND DOOR LAYING ON DECK AND STAIRS HAMPERING EGRESS, DANGEROUS AND HAZARDOUS | 1030 N PARKSIDE AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | FRONT BUILDING/ OWNERS ID SIGN- MISSING. | 1030 N PARKSIDE AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | FRONT BUILDING, TWO STORY REAR WOOD PORCH, HAS UNDERSIZED 4"X6" BEAMS AND 2"X8" RIM JOIST FOR 7'-6" AND 7'-10" SPAN, GUARDRAILS ARE 31" AND MISSING TOP SIDE RAIL, ALL CONNECTIONS SECURED WITH NAILS, PROVIDE PLAN AND PERMIT TO REPAIR PORCH. | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | FRONT BUILDING, NORTH AND SOUTH ELEVATIONS, MISSING GUTTERS AND DOWNSPOUTS, REAR BUILDING WEST ELEVATION, MISSING DOWNSPOUT. | 1030 N PARKSIDE AVE | COMPLAINT | CLOSED | View |
REPLCE WINDOW PANES, PLEXGLAS | FRONT BUILDING WEST ELEVATION 1ST FLOOR,AND REAR BUILDING, WEST AND SOUTH ELEVATIONS, BROKEN PANES. | 1030 N PARKSIDE AVE | COMPLAINT | CLOSED | View |
MAINTAIN WINDOW | REAR BUILDING, WEST ELEVATION, WINDOWS MISSING FRAME AND EXTERIOR TRIM. | 1030 N PARKSIDE AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | FRONT AND REAR BUILDING, NO ENTRY TO VERIFY OCCUPANCY AND DETECTORS. | 1030 N PARKSIDE AVE | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | FRONT BUILDING, TWO STORY REAR PORCH, HAS UNDERSIZED 4"X6" BEAMS AND 2"X8" RIBBON JOIST FOR 7'-6" AND 7'-10" SPAN, GUARDRAILS ARE 31" AND MISSING TOP SIDE RAIL, ALL CONNECTIONS ARE FASTENED WITH NAILS ONLY, PROVIDE PLAN AND PERMIT TO REPAIR OR REPLACE PORCH. | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | WEST AND SOUTH WINDOWS, SEVERAL WINDOWS, MISSING EXTERIOR ALUMINUM CAPPING. | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | FRONT BUILDING/ REAR EXTERIOR 2 STORY PORCH/ COLUMNS- BEAMS AND RIM JOISTS NOTCHED IN AT SAME LOCATION. STAIR HEADER BEAM- WEAK AND SAGGING. UNDERSIZED 2X6 DECK JOISTS SPAN 12 FEET [WEAK AND SAGGING]. STRINGERS- SCABBED SECTIONS. STAIR SECTIONS- WEAK,SAGGING, AND COLLAPSING. RAILING SECTIONS ONLY 24 INCHES HIGH. PLANS AND PERMIT REQUIRED TO REPLACE: FRONT BUILDING- REAR EXTERIOR 2 STORY PORCH. | 1030 N PARKSIDE AVE | COMPLAINT | PASSED | View |
FIRE DAMAGE, SINGED,SOOT | REAR BUILDING SEVERELY FIRE DAMAGED. DEMOLITION PERMIT REQUIRED FOR REMOVAL. PLANS AND PERMITS REQUIRED FOR ALL REPAIRS, WITH ALL WORK PERFORMED SUBJECT TO FIELD INSPECTION, AND APPROVAL BY ALL RELATED TRADES. | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT BUILDING, TWO STORY REAR WOOD PORCH, HAS UNDERSIZED 4"X6" BEAMS AND 2"X8" RIM JOIST FOR 7'-6" AND 7'-10" SPAN, GUARDRAILS ARE 31" AND MISSING TOP SIDE RAIL, ALL CONNECTIONS SECURED WITH NAILS, PROVIDE PLAN AND PERMIT TO REPAIR PORCH. | 1030 N PARKSIDE AVE | COMPLAINT | CLOSED | View |
FIRE DAMAGE, SINGED,SOOT | REAR BUILDING SEVERELY FIRE DAMAGED. DEMOLITION PERMIT REQUIRED FOR REMOVAL. PLANS AND PERMITS REQUIRED FOR ALL REPAIRS, WITH ALL WORK PERFORMED SUBJECT TO FIELD INSPECTION, AND APPROVAL BY ALL RELATED TRADES. | 1030 N PARKSIDE AVE | COMPLAINT | PASSED | View |
ARRANGE FOR REINSPECTION REGAR | FRONT AND REAR BUILDING, NO ENTRY TO VERIFY DETECTORS. | 1030 N PARKSIDE AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | FRONT BUILDING/ EAST ELEVATION/ 1ST FLOOR WINDOW- BROKEN PANE. | 1030 N PARKSIDE AVE | COMPLAINT | PASSED | View |