Chicago Building Violations Data: 28 Violations
Violation Inspector Comments Address Category Status View
REPAIR INTERIOR STAIR SYSTEM INTERIOR STAIR SYSTEM FROM 1ST FLOOR TO BASEMENT; MISSING HAND RAIL. 3308 W 66TH PL COMPLAINT PASSED View
REPAIR LINTELS LINTELS BASEMENT WINDOWS AT SOUTH ELEVATION; SAGGING AND RUSTED. 3308 W 66TH PL COMPLAINT PASSED View
REPAIR EXTERIOR WALL STRESS FRACTURES AT SOUTH ELEVATION EXTERIOR WALL. 3308 W 66TH PL COMPLAINT PASSED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTOR AT BASEMENT, BASEMENT FURNACE ROOM, AND 2ND FLOOR OF REAR ENCLOSED PORCH. DANGEROUS AND HAZARDOUS. 3308 W 66TH PL COMPLAINT PASSED View
CARB MONOX DETECT IN RESID MISSING CARBON MONOXIDE AT BASEMENT FURNACE ROOM. DANGEROUS AND HAZARDOUS. 3308 W 66TH PL COMPLAINT PASSED View
DEBRIS, EXCESSIVE FURNACE ROOM AT BASEMENT FULL OF JUNK AND DEBRIS. FIRE HAZARD. DANGEROUS AND HAZARDOUS. 3308 W 66TH PL COMPLAINT PASSED View
1-HR HEATING PLANT ENCLOSURE FURNACE ROOM IN BASEMENT WITH EXPOSED WOODEN STUDS ON THE INTERIOR OF THE ROOM. DANGEROUS AND HAZARDOUS. 3308 W 66TH PL COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT AND ATTIC OR RESTORE THE BUILDING TO THE ORIGINAL STATE. 3308 W 66TH PL COMPLAINT PASSED View
CONTRARY TO ORIGINAL PLAN ORIGINALLY A SINGLE FAMILY RESIDENCE, NOW THERE ARE LOAD AND NON-LOAD BEARING WALLS IN THE BASEMENT AND ATTIC FORMING BEDROOMS, CLOSETS, KITCHEN, AND BATHROOMS. 3308 W 66TH PL COMPLAINT PASSED View
EGRESS -BASEMENT BASEMENT DWELLING UNIT; ONLY ONE EGRESS EXISTS (IN THE REAR). 3308 W 66TH PL COMPLAINT PASSED View
PRV DISCHARGE PIPE FROM PRV REMOVE UNAPPROVED PVC DISCHARGE LINE ON HOT WATER TANK IN BASEMENT AND REPLACE WITH METAL DISCHARGE LINE. 3308 W 66TH PL COMPLAINT PASSED View
PRV BALLCOCK,VB,OR AIR GAP NO VACUUM BREAKER ON HOSE BIB AT WEST ELEVATION. PROVIDE VACUUM BREAKER FOR HOSE BIB. 3308 W 66TH PL COMPLAINT PASSED View
INSTALL COVERS OPEN BOX WITH EXPOSED WIRES AT 1ST FLOOR FRONT BEDROOM CEILING. OPEN BOX WITH EXPOSED WIRES AT REAR EXTERIOR BELOW PORCH. ALL DANGEROUS AND HAZARDOUS. 3308 W 66TH PL COMPLAINT PASSED View
CONTINUITY OF RACEWAYS RUSTED FLEXIBLE METAL CONDUIT NOT SECURELY ATTACHED TO TRANSITION FITTING AT LOWER REAR EXTERIOR STAIRS. DANGEROUS AND HAZARDOUS. 3308 W 66TH PL COMPLAINT PASSED View
DEFECTIVE OUTLETS LIGHT SWITCH NOT SECURELY ATTACHED TO WALL 1ST FLOOR KITCHEN. 3308 W 66TH PL COMPLAINT PASSED View
CHIMNEY CAPPING CHIMNEY CAP MISSING AT WEST ELEVATION. 3308 W 66TH PL COMPLAINT PASSED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES INCLUDING PLUMBING AND ELECTRIC INSTALLED IN THE BASEMENT AND ATTIC WITHOUT A PERMIT. 3308 W 66TH PL COMPLAINT PASSED View
UNAPPROVED USE OF FLEXIBLE METAL CONDUIT AT REAR EXTERIOR AND REAR INTERIOR STAIRS. 3308 W 66TH PL COMPLAINT PASSED View
CORRODED CONDUIT & EQUIP RUSTED RACEWAYS INCLUDING RMC, EMT AND FLEXIBLE METAL CONDUIT AT REAR EXTERIOR. 3308 W 66TH PL COMPLAINT PASSED View
PROVIDE PLANS AND PERMITS FOR THE INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES AND EQUIPMENT INSTALLED THROUGHOUT THE 1ST FLOOR, ATTIC AND BASEMENT. BUILT OUT ATTIC APARTMENT, BUILT OUT BASEMENT APARTMENT, NEW ELECTRIC THROUGHOUT 1ST FLOOR. INSUFFICIENT PERMITS WITH NO INSPECTIONS. 3308 W 66TH PL COMPLAINT PASSED View
PROVIDE ROUGH INSPECTIONS FOR THE INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES, AND EQUIPMENT INSTALLED THROUGHOUT THE 1ST FLOOR, ATTIC AND BASEMENT. BUILT OUT ATTIC APARTMENT, BUILT OUT BASEMENT APARTMENT, NEW ELECTRIC THROUGHOUT 1ST FLOOR. INSUFFICIENT PERMITS WITH NO INSPECTIONS. 3308 W 66TH PL COMPLAINT PASSED View
PROVIDE PERMIT TO CORRECT VIOLATIONS. 3308 W 66TH PL COMPLAINT PASSED View
REPAIR EXTERIOR STAIR MISSING HANDRAIL GRADE TO BASEMENT AT NORTH ELEVATION. WOODEN STAIRS AT NORTH ELEVATION WITH UNDERSIZED AND LOOSE HAND RAILS. EXTERIOR CONCRETE STAIRS AT SOUTH ELEVATION; DIFFERENT SIZE RISER HEIGHTS, UN-LEVEL TREADS, WING WALL SEPARATING FROM STAIRS. 3308 W 66TH PL COMPLAINT PASSED View
DEFECTIVE SERVICE INSTALL COMMON METER AND CORRECT NUMBER OF APARTMENT METERS UNLESS SINGLE FAMILY RESIDENCE. SERVICE ENTRANCE CABLE NOT ATTACHED TO METER FITTING. SERVICE ENTRANCE CABLE HAS BEEN PAINTED AND IS POSSIBLY DETERIORATED. 3308 W 66TH PL COMPLAINT PASSED View
WORK NOT ALLOWED FENCE OVER 5'. REMOVE, REDUCE HEIGHT, OR OBTAIN PERMIT. 3308 W 66TH PL COMPLAINT PASSED View
EGRESS ATTIC DWELLING UNIT; ONLY ONE EGRESS EXISTS (IN THE REAR). 3308 W 66TH PL COMPLAINT PASSED View
SEE INSPECTOR COMMENTS NEED ILLUMINATION AND 3-WAY SWITCHING AT INTERIOR BASEMENT STAIRS. 3308 W 66TH PL COMPLAINT PASSED View
PROPER MATRL WATER SUPPLY PIPE REMOVE UNAPPROVED FLEXIBLE SUPPLY LINE AT TOILETS, LAVATORIES AND KITCHEN SINK. REMOVE AT ALL LOCATIONS AND ALL ELEVATIONS THROUGHOUT THE ENTIRE PREMISE. HARD PIPE ALL FIXTURE WITH APPROVED WATER SUPPLY LINES. 3308 W 66TH PL COMPLAINT PASSED View