The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIR SYSTEM FROM 1ST FLOOR TO BASEMENT; MISSING HAND RAIL. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
REPAIR LINTELS | LINTELS BASEMENT WINDOWS AT SOUTH ELEVATION; SAGGING AND RUSTED. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | STRESS FRACTURES AT SOUTH ELEVATION EXTERIOR WALL. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTOR AT BASEMENT, BASEMENT FURNACE ROOM, AND 2ND FLOOR OF REAR ENCLOSED PORCH. DANGEROUS AND HAZARDOUS. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE AT BASEMENT FURNACE ROOM. DANGEROUS AND HAZARDOUS. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | FURNACE ROOM AT BASEMENT FULL OF JUNK AND DEBRIS. FIRE HAZARD. DANGEROUS AND HAZARDOUS. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
1-HR HEATING PLANT ENCLOSURE | FURNACE ROOM IN BASEMENT WITH EXPOSED WOODEN STUDS ON THE INTERIOR OF THE ROOM. DANGEROUS AND HAZARDOUS. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT AND ATTIC OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
CONTRARY TO ORIGINAL PLAN | ORIGINALLY A SINGLE FAMILY RESIDENCE, NOW THERE ARE LOAD AND NON-LOAD BEARING WALLS IN THE BASEMENT AND ATTIC FORMING BEDROOMS, CLOSETS, KITCHEN, AND BATHROOMS. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
EGRESS -BASEMENT | BASEMENT DWELLING UNIT; ONLY ONE EGRESS EXISTS (IN THE REAR). | 3308 W 66TH PL | COMPLAINT | PASSED | View |
PRV DISCHARGE PIPE FROM PRV | REMOVE UNAPPROVED PVC DISCHARGE LINE ON HOT WATER TANK IN BASEMENT AND REPLACE WITH METAL DISCHARGE LINE. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
PRV BALLCOCK,VB,OR AIR GAP | NO VACUUM BREAKER ON HOSE BIB AT WEST ELEVATION. PROVIDE VACUUM BREAKER FOR HOSE BIB. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
INSTALL COVERS | OPEN BOX WITH EXPOSED WIRES AT 1ST FLOOR FRONT BEDROOM CEILING. OPEN BOX WITH EXPOSED WIRES AT REAR EXTERIOR BELOW PORCH. ALL DANGEROUS AND HAZARDOUS. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
CONTINUITY OF RACEWAYS | RUSTED FLEXIBLE METAL CONDUIT NOT SECURELY ATTACHED TO TRANSITION FITTING AT LOWER REAR EXTERIOR STAIRS. DANGEROUS AND HAZARDOUS. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
DEFECTIVE OUTLETS | LIGHT SWITCH NOT SECURELY ATTACHED TO WALL 1ST FLOOR KITCHEN. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
CHIMNEY CAPPING | CHIMNEY CAP MISSING AT WEST ELEVATION. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES INCLUDING PLUMBING AND ELECTRIC INSTALLED IN THE BASEMENT AND ATTIC WITHOUT A PERMIT. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
UNAPPROVED USE OF FLEXIBLE METAL CONDUIT AT REAR EXTERIOR AND REAR INTERIOR STAIRS. | 3308 W 66TH PL | COMPLAINT | PASSED | View | |
CORRODED CONDUIT & EQUIP | RUSTED RACEWAYS INCLUDING RMC, EMT AND FLEXIBLE METAL CONDUIT AT REAR EXTERIOR. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
PROVIDE PLANS AND PERMITS FOR THE INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES AND EQUIPMENT INSTALLED THROUGHOUT THE 1ST FLOOR, ATTIC AND BASEMENT. BUILT OUT ATTIC APARTMENT, BUILT OUT BASEMENT APARTMENT, NEW ELECTRIC THROUGHOUT 1ST FLOOR. INSUFFICIENT PERMITS WITH NO INSPECTIONS. | 3308 W 66TH PL | COMPLAINT | PASSED | View | |
PROVIDE ROUGH INSPECTIONS FOR THE INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES, AND EQUIPMENT INSTALLED THROUGHOUT THE 1ST FLOOR, ATTIC AND BASEMENT. BUILT OUT ATTIC APARTMENT, BUILT OUT BASEMENT APARTMENT, NEW ELECTRIC THROUGHOUT 1ST FLOOR. INSUFFICIENT PERMITS WITH NO INSPECTIONS. | 3308 W 66TH PL | COMPLAINT | PASSED | View | |
PROVIDE PERMIT TO CORRECT VIOLATIONS. | 3308 W 66TH PL | COMPLAINT | PASSED | View | |
REPAIR EXTERIOR STAIR | MISSING HANDRAIL GRADE TO BASEMENT AT NORTH ELEVATION. WOODEN STAIRS AT NORTH ELEVATION WITH UNDERSIZED AND LOOSE HAND RAILS. EXTERIOR CONCRETE STAIRS AT SOUTH ELEVATION; DIFFERENT SIZE RISER HEIGHTS, UN-LEVEL TREADS, WING WALL SEPARATING FROM STAIRS. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
DEFECTIVE SERVICE | INSTALL COMMON METER AND CORRECT NUMBER OF APARTMENT METERS UNLESS SINGLE FAMILY RESIDENCE. SERVICE ENTRANCE CABLE NOT ATTACHED TO METER FITTING. SERVICE ENTRANCE CABLE HAS BEEN PAINTED AND IS POSSIBLY DETERIORATED. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | FENCE OVER 5'. REMOVE, REDUCE HEIGHT, OR OBTAIN PERMIT. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
EGRESS | ATTIC DWELLING UNIT; ONLY ONE EGRESS EXISTS (IN THE REAR). | 3308 W 66TH PL | COMPLAINT | PASSED | View |
SEE INSPECTOR COMMENTS | NEED ILLUMINATION AND 3-WAY SWITCHING AT INTERIOR BASEMENT STAIRS. | 3308 W 66TH PL | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE UNAPPROVED FLEXIBLE SUPPLY LINE AT TOILETS, LAVATORIES AND KITCHEN SINK. REMOVE AT ALL LOCATIONS AND ALL ELEVATIONS THROUGHOUT THE ENTIRE PREMISE. HARD PIPE ALL FIXTURE WITH APPROVED WATER SUPPLY LINES. | 3308 W 66TH PL | COMPLAINT | PASSED | View |