Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR/REPLACE SMOKE DETECTORS | SMOKE DETECTOR NOT IN SERVICE TOP OF FRONT STAIRWELL. | 6322 N MOZART ST | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | CENTRAL BOILER UNIT NOT IN SERVICE. NO HEAT BEING GENERATED. | 6322 N MOZART ST | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | BOILER ROOM SMOKE DETECTOR NOT IN SERVICE. | 6322 N MOZART ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BOILER ROOM CO DETECTOR NOT IN SERVICE. | 6322 N MOZART ST | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE WEST ELEVATION MISSING AND DAMAGED SIDING, LOOSE SIDING. GARAGE SERVICE DOORS ROTTING FRAMES AND DOORS, HOLES, RAT HARBOR. EAST ELEVATION AT GRADE; ERODED MORTAR, SPALLING BRICK, OPEN MORTAR JOINTS. | 6322 N MOZART ST | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | UNIT 3 SMOKE DETECTOR NOT OPERATING. | 6322 N MOZART ST | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT INTERIOR STAIRWELL AT 3 GUARDRAIL MISSING PICKETS. | 6322 N MOZART ST | PERIODIC | FAILED | View |
REPAIR DOOR FRAME, MULLION | UNIT 3 DOOR CASING/ TRIM; LOOSE, FALLING. | 6322 N MOZART ST | PERIODIC | FAILED | View |
RESET LOOSE FIXTURE | UNIT 3 KITCHEN SINK LOOSE, NOT SECURE. | 6322 N MOZART ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION FRONT ENTRY MASONRY ARCH AND STONE FRACTURES, OPEN MORTAR JOINTS. | 6322 N MOZART ST | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | EAST ELEVATION AT 1 OPEN SILL JOINTS. | 6322 N MOZART ST | PERIODIC | FAILED | View |
RELOCATE SMOKE DETECTOR | FRONT INTERIOR STAIRWELL SMOKE DETECTOR LOCATED BESIDE UNIT DOOR 20'' DOWN OFF THE CEILING. | 6322 N MOZART ST | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | UNIT 3 2ND BEDROOM WALL OPOENED UPO FOR PLUMBING ACCESS. CLOSE WALL AND FINISH SURFACE. BATHROOM WALL TILE LOOSE TILE, TILE LIFTING, FRACTURED GROUT, MILDEW. | 6322 N MOZART ST | PERIODIC | FAILED | View |
FLOOR, KIT & BATH NON-ABSORB | UNIT 3 KITCHEN FLOOR TILE LOOSE. | 6322 N MOZART ST | PERIODIC | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | 2ND BATHROOM TUB DRAINS SLOWLY. | 6322 N MOZART ST | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED 2013 TO PRESENT. | 6322 N MOZART ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR EXTERIOR 3 STORY WOOD PORCH ROTTING SOUTH WEST 6X6 COLUMN ABOVE AND BELOW EACH LANDING (SIGNIFICANT ROTT). ROTTING STRINGER HEADER AT 3. 2X BEAMS AND COLUMNS FASTENED/ ANCHORED WITH NAILS ONLY. RAILS AND STRINGER ANCHORED/ FASTENED WITH NAILS ONLY. JOISTS ANCHORED WITH NAILS ONLY. LOOSE AND DEFLECTING RAILS. 6X6 COLUMND NOTCHED ON 2 SIDES FOR BEAM AND JOIST CONNECTIONS. 6X6 COLUMNS WITH FIRE CUT AND JOIST NOTCH IN CLOSE PROXIMITY. STACKED COLUMN CONNECTIONS SECURED WITH METAL STRAPS AND NAILS AND/ OR SCREWS ONLY. AT DECK LEVELS THE JOISTS PAST THE LOOKOUT BEAM ARE NOT CONTINOUS AND ARE INSUFFICIENTLY SUPPORTED, RESULTING IN SAGGING STRINGER HEADERS AND DECK AT STRINGER JOINING LOCATION. ROTTING 6X6 LOOKOUT BEAM AT 3. SINGLE UNDERSIZED 2X8 STRINGER HEADERS SPAN 6' 4''. SINGLE 2X8 RIM JOIST/ LANDING BEAM SPANS 10' 4'' AND IS SAGGING. WORN TREADS. OBTAIN PLAN AND PERMIT. | 6322 N MOZART ST | PERIODIC | FAILED | View |
NO KEY TO USE EXIT DOOR | GANG WAY AND REAR GATES REQUIRE KEY TO EXIT. | 6322 N MOZART ST | PERIODIC | FAILED | View |