Chicago Building Violations Data: 18 Violations
Violation Inspector Comments Address Category Status View
REPAIR/REPLACE SMOKE DETECTORS SMOKE DETECTOR NOT IN SERVICE TOP OF FRONT STAIRWELL. 6322 N MOZART ST COMPLAINT FAILED View
SAFE WORKING CONDITIONS CENTRAL BOILER UNIT NOT IN SERVICE. NO HEAT BEING GENERATED. 6322 N MOZART ST COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS BOILER ROOM SMOKE DETECTOR NOT IN SERVICE. 6322 N MOZART ST COMPLAINT FAILED View
CARB MONOX DETECT IN RESID BOILER ROOM CO DETECTOR NOT IN SERVICE. 6322 N MOZART ST COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED GARAGE WEST ELEVATION MISSING AND DAMAGED SIDING, LOOSE SIDING. GARAGE SERVICE DOORS ROTTING FRAMES AND DOORS, HOLES, RAT HARBOR. EAST ELEVATION AT GRADE; ERODED MORTAR, SPALLING BRICK, OPEN MORTAR JOINTS. 6322 N MOZART ST PERIODIC FAILED View
REPAIR/REPLACE SMOKE DETECTORS UNIT 3 SMOKE DETECTOR NOT OPERATING. 6322 N MOZART ST PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM FRONT INTERIOR STAIRWELL AT 3 GUARDRAIL MISSING PICKETS. 6322 N MOZART ST PERIODIC FAILED View
REPAIR DOOR FRAME, MULLION UNIT 3 DOOR CASING/ TRIM; LOOSE, FALLING. 6322 N MOZART ST PERIODIC FAILED View
RESET LOOSE FIXTURE UNIT 3 KITCHEN SINK LOOSE, NOT SECURE. 6322 N MOZART ST PERIODIC FAILED View
REPAIR EXTERIOR WALL EAST ELEVATION FRONT ENTRY MASONRY ARCH AND STONE FRACTURES, OPEN MORTAR JOINTS. 6322 N MOZART ST PERIODIC FAILED View
REPAIR WINDOW SILLS EAST ELEVATION AT 1 OPEN SILL JOINTS. 6322 N MOZART ST PERIODIC FAILED View
RELOCATE SMOKE DETECTOR FRONT INTERIOR STAIRWELL SMOKE DETECTOR LOCATED BESIDE UNIT DOOR 20'' DOWN OFF THE CEILING. 6322 N MOZART ST PERIODIC FAILED View
REPAIR INTERIOR WALLS/CEILING UNIT 3 2ND BEDROOM WALL OPOENED UPO FOR PLUMBING ACCESS. CLOSE WALL AND FINISH SURFACE. BATHROOM WALL TILE LOOSE TILE, TILE LIFTING, FRACTURED GROUT, MILDEW. 6322 N MOZART ST PERIODIC FAILED View
FLOOR, KIT & BATH NON-ABSORB UNIT 3 KITCHEN FLOOR TILE LOOSE. 6322 N MOZART ST PERIODIC FAILED View
REMV OBSTR FROM DRAINAGE SYSTM 2ND BATHROOM TUB DRAINS SLOWLY. 6322 N MOZART ST PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING NOT REGISTERED 2013 TO PRESENT. 6322 N MOZART ST PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR EXTERIOR 3 STORY WOOD PORCH ROTTING SOUTH WEST 6X6 COLUMN ABOVE AND BELOW EACH LANDING (SIGNIFICANT ROTT). ROTTING STRINGER HEADER AT 3. 2X BEAMS AND COLUMNS FASTENED/ ANCHORED WITH NAILS ONLY. RAILS AND STRINGER ANCHORED/ FASTENED WITH NAILS ONLY. JOISTS ANCHORED WITH NAILS ONLY. LOOSE AND DEFLECTING RAILS. 6X6 COLUMND NOTCHED ON 2 SIDES FOR BEAM AND JOIST CONNECTIONS. 6X6 COLUMNS WITH FIRE CUT AND JOIST NOTCH IN CLOSE PROXIMITY. STACKED COLUMN CONNECTIONS SECURED WITH METAL STRAPS AND NAILS AND/ OR SCREWS ONLY. AT DECK LEVELS THE JOISTS PAST THE LOOKOUT BEAM ARE NOT CONTINOUS AND ARE INSUFFICIENTLY SUPPORTED, RESULTING IN SAGGING STRINGER HEADERS AND DECK AT STRINGER JOINING LOCATION. ROTTING 6X6 LOOKOUT BEAM AT 3. SINGLE UNDERSIZED 2X8 STRINGER HEADERS SPAN 6' 4''. SINGLE 2X8 RIM JOIST/ LANDING BEAM SPANS 10' 4'' AND IS SAGGING. WORN TREADS. OBTAIN PLAN AND PERMIT. 6322 N MOZART ST PERIODIC FAILED View
NO KEY TO USE EXIT DOOR GANG WAY AND REAR GATES REQUIRE KEY TO EXIT. 6322 N MOZART ST PERIODIC FAILED View