Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
CARB MONOX DETECT IN ASSEMBLY | NO CARBON MONOXIDE DETECTOR AT 1ST FLR | 3114 W LAKE ST | COMPLAINT | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | NO TAGGED FIRE EXTINGUISHERS | 3114 W LAKE ST | COMPLAINT | FAILED | View |
POST APPROVED OCCUPANCY CARD | POST OCCUPANCY CARD FOR DINING AND VIP ROOMS | 3114 W LAKE ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | UNEVEN RISERS AT REAR RAISED PLATFORM; NO LANDING AT REAR EXIT DOOR (STAIRS LEAD RIGHT INTO DOOR) | 3114 W LAKE ST | COMPLAINT | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | PROVIDE ONE HOUR FIRE RATED ENCLOSURE AT EAST AND WEST FURNACES | 3114 W LAKE ST | COMPLAINT | FAILED | View |
PROVIDE CLASS A FIRE DOOR | PROVIDE CLASS "A" FIRE DOORS AT GARAGE AND KITCHEN SEPARATION | 3114 W LAKE ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PROVIDE PLANS AND PERMITS FOR CHANGE OF USE FROM "E" TO "C2" OCCUPANCY CLASSIFICATION; EXPANSION /BREACHES FROM 3114 TO 3116 (DOORS / OPENINGS) | 3114 W LAKE ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | ALLEVIATION-FRACTURES & WASHED MORTAR AT VARIOUS LOCATIONS THRU OUT | 3114 W LAKE ST | COMPLAINT | FAILED | View |
REPAIR COPING | MISSING COPING STONES AT EAST ELEVATION | 3114 W LAKE ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | UNEVEN RISERS AT REAR RAISE PLATFORM (STAGE), NO LANDING AT REAR EXIT DOOR (STAIRS LEAD RIGHT TO EXIT DOOR) | 3114 W LAKE ST | COMPLAINT | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | PROVIDE CLASS B DOORS AT FURNACE ENCLOSURES | 3114 W LAKE ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS & PERMIT FOR EXPANSION INTO 3116 BUILDING, ALTERATIONS, FIRE SEPERATION: 1) FIREWALLS BREACHED BETWEEN 3114 & 3116 BUILDINGS PERMIT FOR BUILDINGS AS SAME USE 2) 3114 BUILDINGS COMPLETELY GUTTED FOR USE A BANQUET HALL, STAGE BUILT, BATHROOMS REMOVED PLUMBING, HVAC & ELECTRICAL WORK DONE WITHOUT PERMITS | 3114 W LAKE ST | COMPLAINT | FAILED | View |
FOLLOW PLANS/RESUBMIT REVISED | 3114 W LAKE ST | PERMIT | PASSED | View | |
REPAIR EXTERIOR DOOR | REAR EXIT DOOR 32" WIDE, FRONT EXIT DOOR SWINGS AGAINST DIRECTION OF TRAVEL | 3114 W LAKE ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | REPAIR LOOSE DRYWALL AT FRONT STAIRS (3114) | 3114 W LAKE ST | COMPLAINT | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | PROVIDE CLASS "B" FIRE DOORS WITH FRAME AND CLOSERS AT EAST AND WEST FURNACES | 3114 W LAKE ST | COMPLAINT | FAILED | View |
PROVIDE | PROVIDE 4 HOUR FIRE SEPARATION FROM GARAGE AND KITCHEN PER CBC SECTION 3(13-13-56-280) | 3114 W LAKE ST | COMPLAINT | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | PROVIDE ONE HOUR FIRE RATED ENCLOSURE AT EAST & WEST FURNACES | 3114 W LAKE ST | COMPLAINT | FAILED | View |