The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
SAFE WORKING CONDITIONS | BOILER- OUT OF SERVICE AT TIME OF INSPECTION. | 1753 W GARFIELD BLVD | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | 1N-TENANT USING STOVE AND ELECTRIC HEATER FOR HEATING UNIT. | 1753 W GARFIELD BLVD | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | ROOM TEMPERATURE 55 AND 58 DEGREE, HEATING SYSTEM IS OFF AT TIME OF INSPECTION, NO HEAT PROVIDED. | 1753 W GARFIELD BLVD | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | NORTH ELEVATION - MISSING ONE WINDOW SCREEN. | 1753 W GARFIELD BLVD | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | 3 STORY PORCH: COLUMNS ERECTED ON TOP OF CONCRETE BASE. FOOTING UNKOWN TYPE. COLUMNS STACKED ONE ON TOP OF OTHER.; UNDERSIZED 6"X6" BEAMS SPAN IS 12'-8" AND ARE FASTENED TO COLUMNS WITH A 3"X3" STEEL ANGLE.; UNDERSIZED 2"X6" JOISTS SPAN APROX. 10'-0".; STRINGERS AND RAILINGS END POST TO WALL - FASTENED WITH NAILS ONLY.; GUARDRAILS OVER 4'-0" LONG, MISSING INTERMEDIATE SUPPORT. COLUMN BEAM AND RIM JOIST NOTCH ARE 6" APART. PLANS AND PERMIT ARE REQUIRED TO REPLACE D&H PORCH. | 1753 W GARFIELD BLVD | COMPLAINT | PASSED | View |