The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | FRONT BUILDING 1157 N./ REAR 2-STORY ENCLOSED PORCH/ LANDING BETWEEN 1ST FLOOR AND ATTIC - ROTTED DECK BOARDS AND RIM JOIST. STRINGERS - UPPER ENDS INADEQUATELY SUPPORTED AND FASTENED WITH NAILS ONLY. LANDING DECK JOISTS - ONLY NAILED TO HEADER JOISTS AND LEDGER BEAMS. LEDGER BEAMS ONLY NAILED TO BUILDINBG'S EXTERIOR WALL. ALL RAILINGS - ROTTED WOOD MEMBERS AND ONLY NAILED TO POSTS. STAIR RAILINGS - LADDER TYPE CONSTRUCTION WITH 14 TO 16 INCHES BETWEEN MEMBERS. PERMIT ONLY REQUIRED TO REPAIR REAR PORCH. | 1157 N KEDVALE AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | FRONT BUILDING ALL ELEVATONS - ROTTED EAVES. | 1157 N KEDVALE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | ALL ELEVATIONS INCLUDING REAR BUILDING - FRACTURES, LOOSE AND ERODED MORTAR/SPALLED BRICKS AT VARIOUS LOCATIONS. FRONT BUILDING NORTH ELEVATION - LOOSE AND MISSING SIDING PANELS. | 1157 N KEDVALE AVE | COMPLAINT | FAILED | View |
REPAIR / REBUILD SHED | REAR CARPORT CANOPY - MISSING BOLTS AT UNDERSIZED STRUCTURAL MEMBERS, MISSING FOOTINGS. PLANS AND PERMITS ARE REQUIRED FOR CARPORT AND REPAIRS/REBUILD . ALL WORK IS SUBJECT TO FIELD INSPECTION AND APPROVAL. (SEC 14A-4-404.1) | 1157 N KEDVALE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | ALL ELEVATIONS INCLUDING REAR BUILDING - ROTTED WINDOW CASING BOARDS AND SASHES. , BROKEN WINDOWS. | 1157 N KEDVALE AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING- NO OWNER'S ID SIGN POSTED. | 1157 N KEDVALE AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | FRONT ELEVATION-AT FRONT EXTERIOR PORCH ROOF, DAMAGED SOFIT / FACIA WITH HOLES. | 1157 N KEDVALE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | FRONT ELEVATION ABOVE SECOND FLOOR WINDOWS, FRACTURED MASONRY WITH WASHED OUT MORTAR. | 1157 N KEDVALE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- NO RESPONSE,UNVERIFIED DETECTORS AND CONDITIONS. | 1157 N KEDVALE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | FRONT BUILDING 1157 N./ SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT AND ATTIC OR RESTORE BUILDING TO THE ORIGINAL STATE. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. | 1157 N KEDVALE AVE | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | FRONT BUILDING 1157 N./ REMOVE ALL PARTITIONS AND FIXTURES [INCLUDING PLUMBING AND ELECTRIC] INSTALLED IN THE BASEMENT AND ATTIC WITHOUT A PERMIT. | 1157 N KEDVALE AVE | COMPLAINT | PASSED | View |
EXIT THROUGH BEDROOM/BATHROOM | FRONT BUILDING 1157 N./ ATTIC APARTMENT - FRONT EGRESS GOES THROUGH BEDROOM. | 1157 N KEDVALE AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | FRONT BUILDING 1157 N./ REAR 2-STORY ENCLOSED PORCH/ LANDING BETWEEN 1ST FLOOR AND ATTIC - ROTTED DECK BOARDS AND RIM JOIST. STRINGERS - UPPER ENDS INADEQUATELY SUPPORTED AND FASTENED WITH NAILS ONLY. LANDING DECK JOISTS - ONLY NAILED TO HEADER JOISTS AND LEDGER BEAMS. LEDGER BEAMS ONLY NAILED TO BUILDINBG'S EXTERIOR WALL. ALL RAILINGS - ROTTED WOOD MEMBERS AND ONLY NAILED TO POSTS. STAIR RAILINGS - LADDER TYPE CONSTRUCTION WITH 14 TO 16 INCHES BETWEEN MEMBERS. PERMIT ONLY REQUIRED TO REPAIR REAR PORCH. | 1157 N KEDVALE AVE | COMPLAINT | PASSED | View |