Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | NO ENTRY TO 2 FLOOR/BASEMENT | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER POSTING | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO ALL EXTERIOR ENTRY DOORS | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
UNAPPROVED CORDS | REMOVE ALL UNAPPROVED EXTENSION CORDS AND INSTALL ADDITIONAL OUTLETS OR LIGHT FIXTURE TO AVOID USE OF CORDS | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
13-12-360 PROVIDE PERMIT TO CORRECT VIOLATIONS | 1113 N HARDING AVE | COMPLAINT | FAILED | View | |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHTING FIXTURES THROUGHOUT THE 1ST FLOOR, 2ND FLOOR, AND BASEMENT | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAYS | LOOSE/IMPROPER FITTINGS ON FEEDER CONDUITS AND BRANCH CONDUITS THROUGHOUT BASEMENT, AT PANELS IN BASEMENT, AND AT PANELS IN UNITS AND REAR STAIRS - A DANGEROUS AND HAZARDOUS CONDITION | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | INSTALL GFCI PROTECTION IN THE KITCHEN, BATH, LAUNDRY, 1ST FLOOR, 2ND FLOOR AND BASEMENT | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | EXPOSED WIRING AT BASEMENT DOORBELL TRANSFORMER, FRONT BASEMENT BEDROOM WALL SWITCH, MIDDLE BASEMENT BEDROOM SWITCH, AND BASEMENT MECHANICAL ROOM - A DANGEROUS AND HAZARDOUS CONDITION | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAYS | INSTALL GFCI PROTECTION IN THE KITCHEN, BATHS, BASEMENT AND LAUNDRY ROOMS ON THE 1ST FLOOR, 2ND FLOOR, AND BASEMENT | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
PROPER SIZE GRD ELECTRODE COND | GROUND AND BOND THE SERVICE | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | REPLACE THE DEFECTIVE SWITCHES AND RECEPTACLES THROUGHOUT THE 1ST FLOOR, 2ND FLOOR, AND BASEMENT | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
PROVIDE A PERMIT TO CORRECT VIOLATIONS PURSUANT TO SECTION 13-12-360 OF THE CODE | 1113 N HARDING AVE | COMPLAINT | FAILED | View | |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES, INCLUDING PLUMBING AND ELECTRIC INSTALLED IN THE BASEMENT WITHOUT A PERMIT | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
COVER OUTLETS AND JBS | MISSING TRIM PLATES THROUGHOUT THE 1ST FLOOR, 2ND FLOOR AND BASEMENT - A DANGEROUS AND HAZARDOUS CONDITION | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | REMOVE UNAPPROVED TAP BETWEEN METERS AND INSTALL SINGLE METER ENCLOSURE | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
SUPPORT OUTLET AND JBOX | SUPPORT JUNCTION BOXES THROUGHOUT THE BASEMENT | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
SEC FEEDER/BRANCH | SERVICE ENTRANCE CABLE USED FOR BRANCH CIRCUIT NEAR THE BASEMENT PANELS - A DANGEROUS AND HAZARDOUS CONDITION | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
DEFECTIVE FEEDER | ALL FEEDERS TO 1ST AND 2ND FLOOR APARTMENTS MUST BE INSTALLED IN AN APPROVED MANNER | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN A PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
DEFECTIVE POWER SERVICE | REMOVE UNAPPROVED TAPS AT SERVICE EQUIPMENT AND REMOVE UNAPPROVED SERVICE DISCONNECTS | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAYS | OPEN WIRE MOLD IN THE FIRST FLOOR LIVING ROOM - A DANGEROUS AND HAZARDOUS CONDITION | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
ARMORED CABLE | UNAPPROVED ARMORED CABLE THROUGHOUT THE BASEMENT MECHANICAL ROOM AND AT BASEMENT PANELS - A DANGEROUS AND HAZARDOUS CONDITION | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | OPEN BOXES IN THE BASEMENT BEDROOMS, BASEMENT MECHANICAL ROOM, AND VARIOUS OTHER LOCATIONS THROUGHOUT THE BASEMENT - A DANGEROUS AND HAZARDOUS CONDITION | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
SECURE RACEWAY | SECURE RACEWAYS THROUGHOUT THE BASEMENT | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
ADD RECEPTACLES | ADD RECEPTACLES THROUGHOUT 1ST FLOOR, 2ND FLOOR AND BASEMENT TO EASE EXTENSION CORD USAGE - A DANGEROUS AND HAZARDOUS CONDITION | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
REMOVE EXPOSED CABLE | EXPOSED ROMEX CONNECTED TO THE RECEPTACLE BELOW THE FIRST FLOOR PANEL - A DANGEROUS AND HAZARDOUS CONDITION | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WIRING WHERE REQUIRED THROUGHOUT 1ST FLOOR, 2ND FLOOR AND BASEMENT PURSUANT TO SECTION 18-27-110.7 OF THE CODE | 1113 N HARDING AVE | COMPLAINT | FAILED | View | |
REPAIR EXTERIOR WALL | NORTH WALL HAS LOOSE AND MISSING MORTAR. | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR. | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALK HAS BROKEN CONCRETE CAUSING A TRIP HAZARD. | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | WEST SECURITY DOOR MISSING HANDLE. | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | STEEL GATE UNATTACHED. | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | STEEL PICKET/CHAIN LINK OVER 5', REDUCE HEIGHT, REMOVE, OR OBTAIN A PERMIT. | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | NORTH WINDOWS 1-2ND FLOOR BRICKED UP ALL WORK DONE WITHOUT PROPER MASONS PERMIT. | 1113 N HARDING AVE | COMPLAINT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 1113 N HARDING AVE | PERMIT | FAILED | View |