Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED . | 9232 S BALTIMORE AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR WOOD THREE STORY PORCH , ALL COMPONENTS ROTTED WITH FLAKING PAINT . PORCH REQUIRES REPLACEMENT WITH PLANS AND PERMITS . UNKNOWN FOUNDATION STATUS . COLUMNS ROTTED AT BEAM CONNECTIONS . BEAMS OVERSPANNED AND ONLY NAILED . FLOOR JOIST OVERSPANNED AND UNDERSIZED . NO STAIR HEADER SUPPORT . ALL HANDRAILS AND GUARDRAILS UNDERSIZED AND OVERSPANNED WITH RAILS ONLY 30 INCHES HIGH . LARGE OPEN GAPS BELOW GUARDAILS TO TOP OF STAIR TREADS , FALL HAZARD . | 9232 S BALTIMORE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BULDING - UNVERIFIED CONDITIONS , OCCUPANCY AND DETECTORS . | 9232 S BALTIMORE AVE | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | BUILDING - POSTED ADDRESS NUMBER TOO SMALL AND NOT VISIBLE FROM STREET . THREE INCH LONG ADDRESS NUMBERS REQUIRED . | 9232 S BALTIMORE AVE | COMPLAINT | FAILED | View |
RAT STOP AROUND EXTERIOR | REAR FRAME GARAGE , RAT HOLES AT WALL BASE . | 9232 S BALTIMORE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | REAR ATTIC SASH ROTTED AND DETERIORATED . | 9232 S BALTIMORE AVE | COMPLAINT | FAILED | View |
SERVICE DROP OUT OF REACH | REAR INCOMING POWER SERVICE CABLES WITHIN REACH OFF REAR PORCH . HAZARD TO TENANTS AND OCCUPANTS . | 9232 S BALTIMORE AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | FRONT EAVES , LOOSE AND MISSING METAL . | 9232 S BALTIMORE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT WOOD PORCH , STAIRS AND CATWALK, ALL COMPONENTS ROTTED WITH FLAKING PAINT . PLANS AND PERMIT REQUIRED . UNKNOWN FOUNDATION STATUS .UPRIGHTS UNDERSIZED . FLOOR JOIST UNDERSIZED AND ONLY NAILED . NO STAIR HEADER SUPPORT . ALL HANDRAILS OVERSPANNED , UNDERSIZED WITH PICKETS OVER MAXIMUM SPACING . | 9232 S BALTIMORE AVE | COMPLAINT | FAILED | View |
TENANT ACCESS TO SERVICE | NO TENANT ACCESS TO PANELS | 9232 S BALTIMORE AVE | COMPLAINT | FAILED | View |
DEFECTIVE SERVICE | MAIN DISCONNECT LOCATED ON THIRD FLOOR STAIRS AT EXTERIOR OF BUILDING. NO WEATHERHEAD FOR SERVICE. (14E-2-230.70) (14E-2-230.54(B)) | 9232 S BALTIMORE AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | REAR FRAME GARAGE , WALL BASE SIDING ROTTED AND DETERIORATED WITH HOLES . REAR OVERHEAD DOOR ROTTED AND DETERIORATED . | 9232 S BALTIMORE AVE | COMPLAINT | FAILED | View |