Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 8:48 AM
PIN: 16263070430000
Property Address: 2648 S CENTRAL PARK AVE
City - Zip: CHICAGO - 60623
2023 Property Class: 212
2023 Township: 77 - West Chicago
2023 Neighborhood: 77115
2023 Tax District: 77001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 18 Violations
Violation Inspector Comments Address Category Status View
PROPER SIZE PIPE STORM DRAIN PROPER CONNECTION TO SEWER SYSTEM REQUIRED 2648 S CENTRAL PARK AVE COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE REMOVE ALL P.V.C. WASTE AND VENT PIPING THROUGH OUT ALSO ANY WATER PIPE MATERIAL COMMERICAL PROPERTY 2648 S CENTRAL PARK AVE COMPLAINT FAILED View
OBTAIN PERMIT FOR PLUMBING FOR REPAIRS AND PRESENT WORK 2648 S CENTRAL PARK AVE COMPLAINT FAILED View
ENGAG LIC & BOND PLMBNG CNTRC 2648 S CENTRAL PARK AVE COMPLAINT FAILED View
DEMO DEBRIS NORTH GARAGE - PILE OF DEMOLITION DEBRIS. 2648 S CENTRAL PARK AVE COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED NORTH GARAGE - TORN ROOFING MATERIAL.NORTH GARAGE, SHED ROOF RAFTERS AND BEAM,MADE WITH 2"X4" S.PERMIT REQUIRED FOR REPAIRS. 2648 S CENTRAL PARK AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM SIDE TWO STORY PORCH, GUARD RAILS ARE MISSING PICKETS; GUARD AND HAND RAILING SECTIONS ARE ONLY TOE NAILED TO COLUMNS AND 4"X4" RAILING POSTS.STAIR RISERS ARE 7" TO 11-1/2" HIGH.COLUMNS ERECTED ON TOP OF CONCRETE SLAB, OTHER COLUMNS, FOUNDATION BASES FORMED BY CONCRETE POURED IN AROUND COLUMNS.PLANS AND PERMIT ARE REQUIRED FOR PORCH REPAIRS. 2648 S CENTRAL PARK AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE REAR YARD - JUNK ACCUMULATION. 2648 S CENTRAL PARK AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE, UNABLE TO VERIFY DETECTORS, OCCUPANCY AND INTERIOR CONDITIONS. 2648 S CENTRAL PARK AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL EAST EXTERIOR WALL ABOVE 2ND FLOOR - LEANING OUT TOWARD PUBLIC SIDEWALK.PLANS AND PERMIT ARE REQUIRED FOR EXTERIOR WALL REPAIRS. 2648 S CENTRAL PARK AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING OWNER'S IDENTIFICATION SIGN MISSING. 2648 S CENTRAL PARK AVE COMPLAINT PASSED View
REPAIR INTERIOR STAIR SYSTEM 2648 S. / BASEMENT - LEANING AND ROTTING STAIR SYSTEM. STAIR SYSTEM IS BEEM SUPPORTED WITH VERITICAL 1X AND 2X WOOD MEMBERS. NO STAIR RAILING.2648 S. / WEST ELEVATION / 2ND AND 1ST FLOOR ENCLOSED FRAME ADDITION - MISSING RAILING SYSTEM. 2648 S CENTRAL PARK AVE COMPLAINT PASSED View
PERMIT REQUIRED - CONTRACTOR 2648B S. / 1ST FLOOR STOREFRONT - REAR OF STOREFRONT SPACE RENOVATED TO PROVIDE DWELLING UNIT FOR TENANT INCLUDING ARCHITECTURAL, MECHANIAL ELECTRICAL AND PLUMBING MODIFICATIONS. NO PERMIT OBTAINED. PLANS AND PERMIT REQUIRED. SUBJECT TO FIELD INSPECTION BY ALL RELATED TRADES.2648B S./ 2ND FLOOR APARTMENT - RENOVATION WORK IN PROGRESS, NO PERMIT OBTAINED. PERMIT IS NOW REQUIRED. SUBJECT TO FIELD INSPECTION AND APPROVAL.2648 S. / 1ST FLOOR STOREFRONT - STOREFRONT SPACE RECENTLY RENOVATED, NO PERMIT OBTAINED. PERMIT IS NOW REQUIRED. SUBJECT TO FIELD INSPECTION AND APPROVAL.WEST ELEVATION / ADJACENT TO PUBLIC ALLEY - 8 FOOT 0 INCH HIGH METAL FENCE AND ROLLLING GATE ERECTED WITHOUT A PERMIT. PERMIT IS NOW REQUIRED. SUBJECT TO FIELD INSPECTION AND APPROVAL. 2648 S CENTRAL PARK AVE COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR 2648 S. / BASEMENT - 6X6 STRUCTURAL BEAM SUPPORTING 1ST FLOOR JOISTS HAS SEVERE TERMITE DAMAGE. 6X6 STRUCTURAL BEAM SUPPORTED WITH TEMPORARY LOLLY COLUMN. IN ADDITION THERE ARE ALSO TWO 4X6 COLUMNS BEARING ON THE CONCRETE SLAB WITH NO FOUNDATION. PLANS AND PERMIT REQUIRED FOR STRUCTURAL BEAM REPLACEMENT.2648 S. / WEST ELEVATION / NEWER TWO STORY FRAME ADDITION BUILT, NO PERMIT OBTAINED. PLANS AND PERMIT ARE NOW REQUIRED. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. 2648 S CENTRAL PARK AVE COMPLAINT PASSED View
FLAM LIQ TANK FRONTAGE CONSENT 2648 B. / 1ST FLOOR STOREFRONT - USING PROPANE AS FUEL SOURCE FOR COOKING. 2648 S CENTRAL PARK AVE COMPLAINT PASSED View
EGRESS 2648 B. / 1ST FLOOR STOREFRONT - EGRESS TO SECONDARY EGRESS OBSTRUCTED WITH DWELLING UNIT STORAGE.2648 S. / 2ND FLOOR APARTMENT - EAST INTERIOR STAIRWAY OPENS INTO 1ST FLOOR SOTREFRONT SPACE. 2648 S CENTRAL PARK AVE COMPLAINT PASSED View
REPAIR LINTELS 2648B S. / EAST ELEVATION / MULTIPLE LOCATIONS - RUSTED LINTELS. 2648 S CENTRAL PARK AVE COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION NORTH STORE AND WHERE REQUIRED 2648 S CENTRAL PARK AVE COMPLAINT FAILED View