Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 10:08 PM
PIN: 20342230150000
Property Address: 8149 S EVANS AVE
City - Zip: CHICAGO - 60619
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70120
2023 Tax District: 70001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 51 Violations
Violation Inspector Comments Address Category Status View
POST OWNER/MANAGERS NAME/# POST OWNERSHIP I.D. 8149 S EVANS AVE COMPLAINT PASSED View
POST OWNER/MANAGERS NAME/# BUILDING - OWNER'S ID. SIGN - MISSING MAILING ADDRESS. 8149 S EVANS AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION !ST AND 2ND FLOOR APTS. - NO ENTRY, NO RESPONSE, UNABLE TO VERIFY DETECTORS AND INTERIOR CONDITIONS. 8149 S EVANS AVE COMPLAINT FAILED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES, PLUMBING AND ELECTIC INSTALLED IN THE BASEMENT WITHOUT A PERMIT.ORIGINAL BASEMENT HEATING AND STORAGE SPACE HAS BEEN ALTERED IN TO A DWELLING UNIT. NO PLANS AND PERMIT OBTAINED. 8149 S EVANS AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS REAR PORCH AND BASEMENT STORAGE ROOM - MISSING SMOKE DETECTORS. 8149 S EVANS AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO THE BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. 8149 S EVANS AVE COMPLAINT FAILED View
CEILING HEIGHT - 7' - BASEMENT BASEMENT APT. CEILING HEIGHT - 6'-10-1/2" 8149 S EVANS AVE COMPLAINT FAILED View
SEPARATION OF DWELLING ADEQUAT BASEMENT CEILING ENCLOSED WITH ACOUSTIC TILES ( NOT FIRE RATED). 8149 S EVANS AVE COMPLAINT FAILED View
WINDOW AREA ABOVE GROUND BASEMENT WINDOWS ARE GLASS BLOCK TYPE AND ARE 2'-4"X2'-6". 8149 S EVANS AVE COMPLAINT FAILED View
UNINTERRUPTED EXIT AT GRADE BASEMENT APT., REAR EXIT IS THRU REAR HEATING AND STORAGE ROOM. 8149 S EVANS AVE COMPLAINT FAILED View
PARAPET & COPING OPEN MORTAR JOINTS PARAPET WEST 8149 S EVANS AVE COMPLAINT PASSED View
REPAIR FENCE STEEL PICKET FENCE SCRAPE AND PAINT "RUST SPOTS" 8149 S EVANS AVE COMPLAINT PASSED View
REPAIR EXTERIOR DOOR CRACKED WINDOW FRONT ENTRANCE DOOR WEST 8149 S EVANS AVE COMPLAINT PASSED View
SERVICE WALK, PASSAGE, AREAWAY PATCH CRACKED CONCRETE WALKWAY WEST 8149 S EVANS AVE COMPLAINT PASSED View
REPAIR INTERIOR WALLS/CEILING SMALL HOLES EXPOSED LATH AT WEST INTERIOR HALLWAY. 8149 S EVANS AVE COMPLAINT PASSED View
REPLCE WINDOW PANES, PLEXGLAS ONE MISSING WINDOW PANE, 1ST FLOOR SOUTH AT REAR PORCH TWO MISSING PANES 2ND FLOOR SOUTH AT REAR PORCH 8149 S EVANS AVE COMPLAINT PASSED View
INSTALL DOOR VIEWING DEVICE MISSING PEEP HOLE AT APARTMENT DOORS 8149 S EVANS AVE COMPLAINT PASSED View
MAINTAIN WINDOW SASH ROTTED WINDOW SASH 1ST FLOOR SOUTH 8149 S EVANS AVE COMPLAINT PASSED View
REPAIR INTERIOR STAIR SYSTEM MISSING ONE PICKET BETWEEN 1ST AND 2ND FLOORS WEST INTERIOR STAIRS. 8149 S EVANS AVE COMPLAINT PASSED View
PROVIDE GUTTER & DOWNSPOUT MISSING DOWNSPOUT EAST 8149 S EVANS AVE COMPLAINT PASSED View
REPUTTY WINDOW PANES LOOSE AND MISSING WINDOW PUTTY 1ST FLOOR AND BASEMENT SOUTH 8149 S EVANS AVE COMPLAINT PASSED View
REPAIR/REBUILD GARAGE OR SHED ROTTED SERVICE ENTRANCE DOOR TO GARAGE 8149 S EVANS AVE COMPLAINT PASSED View
SEE INSPECTOR COMMENTS OBTAIN ELECTRICAL PERMIT TO CORRECT ELECTRICAL VIOLATION (13-12-360) 8149 S EVANS AVE COMPLAINT PASSED View
OPEN 8149 S EVANS AVE PERMIT PASSED View
REPAIR FLOOR 3RD FLOOR APT. - KITCHEN TORN FLOOR TILES AND ROTTED SUBFLOOR. 8149 S EVANS AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR THREE STORY ENCLOSED PORCH, STAIRS 2ND FLOOR TO 3RD FLOOR MID-LANDING COLLAPSED ( CREATING A DANGEROUS CONDITION).STRINGERS ARE FASTENED WITH NAILS ONLY.GUARD AND HANDRAILS 4"X4" POSTS ARE FASTENED WITH NAILS ONLY.3RD FLOOR GUARDRAIL IS ONLY 36" HIGH.1ST FLOOR STAIR TREAD - LOOSE.PERMIT ONLY REQUIRED TO REPAIR DANGEROUS PORCH. 8149 S EVANS AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID BASEMENT ( FURNACE ROOM AND DWELLING UNIT) - MISSING CARBON MONOXIDE DETECTORS. 8149 S EVANS AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR FRONT MAIN ENTRY DOOR - LOOSE KICK PLATE.REAR BASEMENT DOOR - DELAMINATED. 8149 S EVANS AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING FRONT VESTIBULE AND FRONT INTERIOR STAIRWAY 2ND TO 3RD - LOOSE WALL-PAPER.3RD FLOOR APT., LIVINGROOM CEILING - PEELING PAINT; WEST WALL - TWO VERTICAL CRACKS. 8149 S EVANS AVE COMPLAINT FAILED View
OBTN PERMIT FOR PLUMBING WORK STOP ALL WORK NO PERMIT UNLICENSE PLUMBER 8149 S EVANS AVE COMPLAINT FAILED View
RMV PLBFIX INSTALLD W/0 PERMIT THROUGH OUT BUILDING 8149 S EVANS AVE COMPLAINT FAILED View
LICENSED BONDED PLMBG CONTRCTR 8149 S EVANS AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY OBSTRUCTED PATHWAYS/ REAR GATE - CHAIN AND PAD LOCKED; INTERIOR STAIRS - ACCUMULATED STORAGE 8149 S EVANS AVE COMPLAINT FAILED View
TENANT ACCESS TO SERVICE ALL TENANTS HAVE NO ACCESS TO BREAKER PANELS IN BASEMENT. 8149 S EVANS AVE COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE 1ST FLOOR APARTMENT/ NORTH AND EAST WINDOWS FRAMES - DRAFTY WINDOWS WITH GAPS AND AIR SEEPAGE. 8149 S EVANS AVE COMPLAINT FAILED View
STOP LEAKING WATER 1ST FLOOR APARTMENT/ BATHROOM CEILING - EVIDENT SIGNS OF LEAKAGE. 8149 S EVANS AVE COMPLAINT FAILED View
REPAIR FLOOR 1ST FLOOR APARTMENT/ FLOORS THROUGHOUT INTERIOR - VARIOUS SMALL CRACKS AND HOLES. 8149 S EVANS AVE COMPLAINT FAILED View
MICE/RODENTS 1ST FLOOR APARTMENT - EVIDENT SIGNS OF MICE INFESTATION. 8149 S EVANS AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING 1ST FLOOR APARTMENT/ BATHROOM CEILING - CRACKED AND BUCKLED PLASTER; EVIDENT SIGNS OF WATER DAMAGE. 8149 S EVANS AVE COMPLAINT FAILED View
NO PERMIT WIRING PROVIDE PLANS AND PERMIT FOR BASEMENT BUILD OUT 8149 S EVANS AVE COMPLAINT FAILED View
TENANT ACCESS TO SERVICE PROVIDE ACCESS FOR MAIN SWITCH NOW LOCARED IN BASEMENT TENANT UNIT 8149 S EVANS AVE COMPLAINT FAILED View
DEFECTIVE OUTLETS DEFECTIVE OULETS THROUGHOUT 1ST FLOOR UNIT COVERD IN PAINT 8149 S EVANS AVE COMPLAINT FAILED View
GAP AT BOX WALL FINISH GAP AT OUTLET 1ST FLOOR UNIT KITCHEN WEST WALL 8149 S EVANS AVE COMPLAINT FAILED View
INSTALL ILLUMINATION ADD LIGHT TO GARAGE ENTRY DOOR 8149 S EVANS AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS APT. - 2 / SMOKE DETECTOR - MISSING. 8149 S EVANS AVE COMPLAINT FAILED View
INSTALL GFCI TO EXTERIOR FRONT WALL OF BUILDING. (18-27-210.8) 8149 S EVANS AVE COMPLAINT PASSED View
DWELLING CLEAN AND SANITARY REAR PORCH, 3RD FLOOR LANDING - STORIN G PAINT AND OTHER ITEMS. 8149 S EVANS AVE COMPLAINT FAILED View
STOP/REMOVE NUISANCE REAR YARD - DOG FECES. 8149 S EVANS AVE COMPLAINT FAILED View
CIRCUIT ONE UNIT ONLY ADD PUBLIC PANEL FOR COMMON LOADS 18-27-210.25 8149 S EVANS AVE COMPLAINT FAILED View
WINDOW OPEN EASILY, STAY OPEN 1ST FLOOR APARTMENT/ NORTH AND EAST WINDOWS - SASHES TAPED TO WINDOW FRAMES; SASHES HARD TO OPEN AND CLOSE; WINDOWS NOT SECURED - BROKEN HARDWARE. 8149 S EVANS AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO APARTMENTS. 8149 S EVANS AVE COMPLAINT PASSED View