Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR OF BUILDING | 5736 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST WOOD FRAMED PORCH HAS UNEVEN RISER. HEIGHTS, MISSING PICKETS, GUARDRAIL HEIGHT INCORRECT, LOOSE TREADS. WEST WOOD FRAMED PORCH MISSING/BROKEN PICKETS, OVER SPANNED STRINGER SUPPORTED BY 2X4. INCORRECT RISER & GUARDRAIL HEIGHTS, OVERCUT STRINGERS & 4X4 SUPPORT COLUMNS. INCORRECT 6X6 SUPPORT COLUMNS SPLICES. STRINGER RESTING ON 2X4 AT SECOND LANDING 3X6 RESTING ON TREAD, CRACKED STRINGER. REQUIRED PLANS/PERMITS TO REPAIR OR REPLACE. | 5736 S THROOP ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALK HAS BROKEN CONCRETE CAUSING A TRIP HAZARD | 5736 S THROOP ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH 1ST FLOOR HAS BROKEN WINDOW PANE | 5736 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH LOWER WALL HAS LOOSE/MISSING MORTAR | 5736 S THROOP ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | WEST WOOD FRAMED PORCH WILL REQUIRE PLANS/PERMITS TO REPAIR OR REPLACE. CURRENT REPAIR MEASURES ATTEMPTED WITHOUT A PERMIT ARE DEFICIENT | 5736 S THROOP ST | COMPLAINT | FAILED | View |
SERVICE DROP OUT OF REACH | RELOCATE SERVICE DROP OUT OF NORMAL REACH | 5736 S THROOP ST | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO ALL ENTRY DOORS INCLUDING GARAGE | 5736 S THROOP ST | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHT FIXTURES AT REAR OF BUILDING. ALL SUPPORT BOXES AND FIXTURES MUST BE WEATHERPROOF. | 5736 S THROOP ST | COMPLAINT | FAILED | View |
INSTALL COVERS | INSTALL COVERS TO ALL OPEN JUNCTION BOXES | 5736 S THROOP ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | SOUTH GRADE TO BASEMENT MISSING HANDRAIL & BROKEN TREAD | 5736 S THROOP ST | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | REPLACE DEFECTIVE POWER SERVICE WITH FRAYED SERVICE ENTRANCE CABLE LINE AND LOAD | 5736 S THROOP ST | COMPLAINT | FAILED | View |
13-12-360 PROVIDE PERMIT TO CORRECT VIOLATIONS | 5736 S THROOP ST | COMPLAINT | FAILED | View | |
POST OWNER/MANAGERS NAME/# | NO OWNER POSTING | 5736 S THROOP ST | COMPLAINT | FAILED | View |