The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP | 5621 S GREEN ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SOUTH SERVICE WALK/BUCKLING,UNEVEN AND DAMAGED SECTIONS | 5621 S GREEN ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR AND FRONT YARD/GARBAGE CANS, AND GARBAGE THRU-FRONT AND REAR | 5621 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH/FOOTING CRACKED, SPACING BETWEEN BOLTS ON LEDGER EXCESSIVE BEAM PULLING APART AT FIRE CUT (COLUMN CONNECTION) LIGHT GAGE METAL COLUMN TO BEAM SHOULD HAVE GALVANIZED HEAVY GAGE "L" BRACKET AT CONNECTION BOTTOM TREAD LOOSE AND WEAK, 1ST FLOOR TREAD CRACKED 1ST FLOOR PICKET DAMAGED PERMIT ONLY NEED FOR REPAIRS. | 5621 S GREEN ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 5621 SOUTH 1ST FLOOR APT/MISSING SMOKE DETECTORS | 5621 S GREEN ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 5621-SOUTH 1ST FLOOR APT/MISSING C/O DETECTOR | 5621 S GREEN ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR OF PROPERTY. | 5621 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST WOOD PORCH HAS UNDERSIZED GUARDRAILS AND INCORRECT RISER HEIGHTS. | 5621 S GREEN ST | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY CAP MISSING. | 5621 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | ALL WALLS VARIOUS LOCATIONS HAS LOOSE, MISSING DETERIORATED BRICK AND MORTAR. | 5621 S GREEN ST | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | STOP ALL WORK UNITL PERMIT IS OBTAINED | 5621 S GREEN ST | COMPLAINT | CLOSED | View |
PLANS & PERMITS REQ - CONTRCTR | INTERIOR ALTERATIONS REMAINING OAND REPLACING PARTITIONS IN ALL 4 UNITS OF 2 STORY MASONARY BUILIDNG | 5621 S GREEN ST | COMPLAINT | CLOSED | View |
HEAT UNIT ADEQUATELY | 1N-ROOM TEMPERATURE READING 47 DEGREE, HEATING SYSTEM IS OFF AT TIME OF INSPECTION. | 5621 S GREEN ST | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | 1N- FURNACE OUT OF SERVICE AT TIME OF INSPECTION. | 5621 S GREEN ST | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | 1N-HOT WATER SHUT OFF. | 5621 S GREEN ST | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | 5621 S GREEN ST | COMPLAINT | FAILED | View | |
PROPER MATRL WATER SUPPLY PIPE | REPLACE FLEX WATER SUPPLIES | 5621 S GREEN ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | CALL FOR INSPECTION AFTER REPAIRS AT 312-743-0413 MON-FRI 8AM 9:30AM | 5621 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION 2 STORY WOOD PORCH 2X6 JOIST SPANNING 12FT.GUARDRAILS ARE MISSING PICKETS,TOENAILED TO COLUMNS AND OVERSPANNED.6X6 COLUMNS ARE OVERNOTCHED.BEAM TO COLUMNS ARE FASTENED WITH NAILS AND PULLING APART AT FIRE CUTS.STATUS OF FOUNDATIONS UNKNOWN.PLAN AND PERMIT REQUIRED TO MAKE REPAIRS. | 5621 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EAST ELEVATION BASEMENT STAIRWELL MISSING HANDRAIL.WEST ELEVATION 1 STORY PORCH GUARDRAILS MISSING PICKETS,OVERSPANNED,TOENAILED TO COLUMNS AND ONLY 32" HIGH. | 5621 S GREEN ST | COMPLAINT | FAILED | View |
LIGHT AND VENT | WEST ELEVATION BASEMENT WINDOWS COVERED WITH SIDING. | 5621 S GREEN ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE/ENTRY AT TIME OF INSPECTION.UNABLE TO GAIN ENTRY TO 2S TO VERIFY COMPLAINT OF ROACH INFESTATION. | 5621 S GREEN ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER I.D SIGN POSTED. | 5621 S GREEN ST | COMPLAINT | FAILED | View |
RAT PROOF BSMENT DOOR | EAST ELEVATION BASEMENT DOOR BROKEN AND WIDE OPEN. | 5621 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION 2 STORY WOOD PORCH 2X6 JOIST SPANNING 12FT.GUARDRAILS ARE MISSING PICKETS,TOENAILED TO COLUMNS AND OVERSPANNED.6X6 COLUMNS ARE OVERNOTCHED.BEAM TO COLUMNS ARE FASTENED WITH NAILS AND PULLING APART AT FIRE CUTS.STATUS OF FOUNDATIONS UNKNOWN.PLAN AND PERMIT REQUIRED TO MAKE REPAIRS. | 5621 S GREEN ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | EAST ELEVATION BASEMENT STAIRWELL MISSING HANDRAIL.WEST ELEVATION 1 STORY PORCH GUARDRAILS MISSING PICKETS,OVERSPANNED,TOENAILED TO COLUMNS AND ONLY 32" HIGH. | 5621 S GREEN ST | COMPLAINT | CLOSED | View |
LIGHT AND VENT | WEST ELEVATION BASEMENT WINDOWS COVERED WITH SIDING. | 5621 S GREEN ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION MASONRY WALL HAS SPALLING BRICKS AND WASHED OUT MORTAR JOINTS. | 5621 S GREEN ST | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE/ENTRY AT TIME OF INSPECTION.UNABLE TO GAIN ENTRY TO 2S TO VERIFY COMPLAINT OF ROACH INFESTATION. | 5621 S GREEN ST | COMPLAINT | CLOSED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER I.D SIGN POSTED. | 5621 S GREEN ST | COMPLAINT | CLOSED | View |
RAT PROOF BSMENT DOOR | EAST ELEVATION BASEMENT DOOR BROKEN AND WIDE OPEN. | 5621 S GREEN ST | COMPLAINT | CLOSED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 1990 THRU 2015. | 5621 S GREEN ST | COMPLAINT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 5621 S GREEN ST | PERMIT | PASSED | View | |
DEBRIS, EXCESSIVE | EAST ELEVATION BASEMENT STAIRWELL AND BASEMENT GARBAGE PILED THROUGHOUT. | 5621 S GREEN ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | EAST ELEVATION BASEMENT STAIRWELL AND BASEMENT GARBAGE PILED THROUGHOUT. | 5621 S GREEN ST | COMPLAINT | CLOSED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 1990 THRU 2015. | 5621 S GREEN ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION MASONRY WALL HAS SPALLING BRICKS AND WASHED OUT MORTAR JOINTS. | 5621 S GREEN ST | COMPLAINT | FAILED | View |