REPAIR EXTERIOR STAIR | HANDRAIL MISSING FROM GRADE TO BASEMENT | 5711 S WOLCOTT AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | GUARDRAIL MISSING AT GRADE FOR BASEMENT AREAWAY | 5711 S WOLCOTT AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | WEST - BASEMENT - TRASH, GARBAGE, DEBRIS IN AREAWAY;NORTH - TRASH , DEBRIS, GARBAGE ON SIDE OF HOUSE | 5711 S WOLCOTT AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | 75" CHAIN LINK FENCE; NO PERMIT OBTAINED | 5711 S WOLCOTT AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL - SPALLING BRICKS | 5711 S WOLCOTT AVE | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | HIGH WEEDS, DEAD TREE TRUNKS IN REAR YARD | 5711 S WOLCOTT AVE | COMPLAINT | FAILED | View |
DEMO DEBRIS | STONE TILES, LUMBER, LADDERS STORED IN REAR YARD | 5711 S WOLCOTT AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | WOODEN FENCE - LEANING TOWARDS ALLEYWAY; UNSECURED | 5711 S WOLCOTT AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER | GUTTERS - CLUTTERED WITH LEAVES, DEBRIS | 5711 S WOLCOTT AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH - FOUNDATION STATUS UNKNOWN; 4X4 COLUMNS OUT OF PLUMB; 2X4 JOISTS SPAN 7'-5"; STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; STRINGER LEANING FROM 1ST TO ATTIC; RAIL HEIGHT ONLY 33 3/4" (ATTIC) AND 36 1/2" (1ST TO ATTIC); SPINDLES SPACED 14" - 17" APART; JOIST HANGERS MISSING; ENTIRE STRUCTURE SWAYS WHEN STANDING ON UPPERMOST LANDING; RAILS AT ATTIC BUILT ON TOP OF ROOF. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH AND AUTHORIZE STAIR SYSTEM (INCLUDING RAILS) TO ATTIC LEVEL. | 5711 S WOLCOTT AVE | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | ELECTRICAL POWER SERVICE CABLES BISECT STAIR STRUCTURE AND TANGIBLE FROM PATHWAY TO ATTIC LEVEL; HAZARDOUS. (SEC. 7-28-040) | 5711 S WOLCOTT AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | WINDOW FRAMES, TRIM - ROTTING AND PAINTED OVER | 5711 S WOLCOTT AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE; NO ENTRY. UNABLE TO INSPECT INTERIOR, STAIRWELLS, BASEMENT, AND ATTIC. UNVERIFIED DETECTORS AND OCCUPANCY. | 5711 S WOLCOTT AVE | COMPLAINT | FAILED | View |
SUBMIT FOR APPROVAL PLANS | 5711 S WOLCOTT AVE | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 5711 S WOLCOTT AVE | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 5711 S WOLCOTT AVE | COMPLAINT | CLOSED | View | |
WATCHMAN | 5711 S WOLCOTT AVE | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 5711 S WOLCOTT AVE | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 5711 S WOLCOTT AVE | COMPLAINT | CLOSED | View | |
POST OWNER NAME OF VACNT BLDG | VIOLATION CLOSED PER PCR 1180 | 5711 S WOLCOTT AVE | COMPLAINT | CLOSED | View |