Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
UNDERSIDE STAIR 1HR FIRE RES | 2ND FLOOR APARTMENT FRONT BEDROOM CLOSET - EXPOSED WOOD UNDERSIDE OF FRONT INTERIOR STAIR UP TO ATTIC. | 6239 S MAY ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT INTERIOR STAIRWAY AND REAR PORCH ALL FLOORS - STORAGE OF LARGE PERSONAL ITEMS THAT HAMPERS EGRESS. | 6239 S MAY ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT 1 STORY OPEN WOOD ENTRY STAIR WITH ROOF - (1) ALL WOOD MEMBERS OF PORCH ARE ROTTEN.(2) ALL CONNECTIONS ARE ONLY FACE NAILED OR TOE NAILED WITH THE EDGES OF WOOD MEMBERS ROTTING AND PULLING AWAY EXPOSING RUSTING NAILS.(3) STAIR LANDING HAS ONLY 2X6 SISTERED JOIST, EDGE BEAMS AND LEDGERS AND ARE MISSING JOIST HANGERS AND SECURE METAL CONNECTIONS TO POST AND THE BUILDING'S FRONT EXTERIOR WALL.(4) SUPPORT POST ARE MISSING BOLTED CONNECTIONS TO BEAMS / JOIST AND REST ON CONCRETE BLOCKS WITH UNKNOWN FOUNDATIONS.(5) WEAK HANDRAILS AND GUARDRAILS ARE ONLY 24 INCHES AND 28 INCHES HIGH, RESPECTIVELY.(6) DRAWINGS AND PERMITS ARE REQUIRED. | 6239 S MAY ST | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR 3 STORY OPEN WOOD PORCH WITH ROOF AND BASEMENT ACCESS - (1) ALL WOOD MEMBERS OF PORCH ARE SEVERLY ROTTED.(2) ALL CONNECTIONS ARE ONLY FACE NAILED OR TOE NAILED WITH THE EDGES OF WOOD MEMBERS ROTTING AND PULLING AWAY EXPOSING RUSTING NAILS.(3) PORCH DECK HAS ONLY 2X6 JOIST, EDGE BEAMS AND LEDGERS AND ARE MISSING JOIST HANGERS AND SECURE METAL CONNECTIONS TO COLUMNS AND THE BUILDING'S REAR EXTERIOR WALL.(4) COLUMNS ARE MISSING BOLTED CONNECTIONS TO BEAMS AND ARE OVERNOTCHED AT BEAM CONNECTIONS AND REST ON CONCRETE BLOCKS WITH UNKNOWN FOUNDATIONS.(5) COLUMN SPLICE CONNECTIONS HAVE ONLY AN 8INCH OVERLAP AND ARE MISSING BOLTED CONNECTIONS.(6) ROTTED WOOD AND VERY WEAK HANDRAILS AND GUARDRAILS ARE ONLY 24 INCHES AND 28 INCHES HIGH, RESPECTIVELY.(7) DRAWINGS AND PERMITS ARE REQUIRED. | 6239 S MAY ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | ATTIC APARTMENT BATHROOM FLOOR - UNEVEN AND EXCESSIVELY SLOPED. | 6239 S MAY ST | COMPLAINT | FAILED | View |
MICE/RODENTS | 2ND FLOOR APARTMENT EAST KITCHEN WINDOW SILL - MANY RODENT DROPPINGS. | 6239 S MAY ST | COMPLAINT | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | NO ENTRY INTO 1ST FLOOR APARTMENT OR BASEMENT TO VERIFY EGRESS, CARBON MONOXIDE DETECTORS, SMOKE DETECTORS, INTERIOR STRUCTURAL, COSMETIC OR ENVIRONMENTAL CONDITIONS. | 6239 S MAY ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | FRONT ELEVATION - MISSING OWNER/MANAGER CONTACT INFORMATION SECURELY AND PERMANENTLY ATTACHED TO THE BUILDING. | 6239 S MAY ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT STAIRWAY, 2ND FLOOR AND ATTIC APARTMENTS - MISSING SMOKE DETECTORS. | 6239 S MAY ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 2ND FLOOR AND ATTIC APARTMENTS - MISSING CARBON MONOXIDE DETECTORS. | 6239 S MAY ST | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING REGISTRATION - NO RECORD OF EVER FILING. | 6239 S MAY ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQUIRED | (1) SOUTH ELEVATION AT ROOF - 2 FRAME DORMERS BUILT WITH NO DRAWINGS OR PERMITS ON FILE.(2) ATTIC SPACES/ROOMS BUILT WITH NO PLANS OR PERMITS ON FILE.(3) PLANS AND PERMITS REQUIRED FOR EXISTING DORMERS AND ROOMS TO REMAIN OR TO REMOVE DORMERS AND RESTORE THE ATTIC INTO ONE LARGE OPEN SPACE/ROOM. | 6239 S MAY ST | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | FRONT AND REAR YARDS - HIGH WEEDS. | 6239 S MAY ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH AT 2 - SECTIONS OF EXTERIOR WALL SIDING MISSING. | 6239 S MAY ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | FRONT ENTRY DOOR - LOCKS AND KNOB BROKEN. | 6239 S MAY ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT STAIRWAY - LOOSE RAILINGS AND TREADS. | 6239 S MAY ST | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | ATTIC APARTMENT - SMOKE DETECTOR - OUT OF SERVICE. | 6239 S MAY ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | ATTIC APARTMENT - CARBON MONOXIDE DETECTOR - MISSING. | 6239 S MAY ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | ATTIC APARTMENT - COLLAPSED CEILING, WITH EXPOSED JOISTS. | 6239 S MAY ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | ATTIC ALTERED INTO A DWELLING UNIT. REMOVE ALL PARTITIONS AND FIXTURES [INCLUDING PLUMBING AND ELECTRIC] INSTALLED IN ATTIC WITHOUT A PERMIT. | 6239 S MAY ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATION IN ATTIC, OR RESTORE THE BUILDING TO THE ORIGINAL CONDITION. | 6239 S MAY ST | COMPLAINT | FAILED | View |
INSECTS | ATTIC APARTMENT - BEDBUGS INFESTATION. PROPERTY MUST BE EFFECTIVELY TREATED TO EXTERMINATE BED BUGS THROUGHOUT, BY EMPLOYING AN EXPERIENCED EXTERMINATOR IN ABATEMENT OF BED BUG INFESTATION. BUILDING DEPARTMENT WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATION | 6239 S MAY ST | COMPLAINT | FAILED | View |
ROACHES | ATTIC APARTMENT - ROACHES INFESTATION. | 6239 S MAY ST | COMPLAINT | FAILED | View |
MICE/RODENTS | ATTIC APARTMENT - MICE INFESTATION. | 6239 S MAY ST | COMPLAINT | FAILED | View |
STOP LEAKING WATER | ATTIC APARTMENT - WATER LEAKING THROUGH CEILING. | 6239 S MAY ST | COMPLAINT | FAILED | View |
STOP ODORS RPR DFT SEWAGE SYS | ATTIC APARTMENT - BATHROOM - SEWER ODORS. | 6239 S MAY ST | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | ATTIC APARTMENT - BATHROOM TOILET AND SINK - CLOGGED DRAIN. | 6239 S MAY ST | COMPLAINT | FAILED | View |
KEEP FIXTUR CLEAN AND SANITARY | ATTIC APARTMENT - BATHROOM TUB, SINK AND TOILET - UNSANITARY CONDITIONS. | 6239 S MAY ST | COMPLAINT | FAILED | View |
PROVIDE HOT WATER TO FIXTURES | ATTIC APARTMENT - BATHROOM AND KITCHEN - NO HOT WATER SUPPLIED TO THE FIXTURES. | 6239 S MAY ST | COMPLAINT | FAILED | View |
PROVIDE COLD WATER TO FICTURES | ATTIC APARTMENT - BATHROOM AND KITCHEN - NO COLD WATER SUPPLIED TO THE FIXTURES. | 6239 S MAY ST | COMPLAINT | FAILED | View |
USE SANITARY REFUSE CONTAINERS | REAR YARD AND BASEMENT - ACCUMULATION OF REFUSE AND GARBAGE. | 6239 S MAY ST | COMPLAINT | FAILED | View |
REPAIR ROOF | ROOF - DAMAGE AND LEAKING. | 6239 S MAY ST | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | 3-STORY REAR PORCH IS IN DANGEROUS AND HAZARDOUS CONDITIONS - UNDERSIZED 2X6 DECK JOISTS SPAN 18', ROTTING AND SAGGING; DECKBOARDS ARE LOOSE, ROTTING AND BUCKLING; RAILING / GUARDRAIL LOOSE, ROTTING AND PULLING, WITH SECTIONS OF GUARDRAIL MISSING AT 2ND AND ATTIC LEVELS. ENTIRE STRUCTURE IS WEAK, UNSTABLE AND SWAYING. PLANS AND PERMIT REQUIRED TO REPLACE REAR PORCH. | 6239 S MAY ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION AT 2 - WINDOW PANES BROKEN. | 6239 S MAY ST | COMPLAINT | FAILED | View |
PROV HOT WTR TO ALL FIXTURES | ALL OCCUPIED APARTMENTS (18-29-607-1) (13-196-420) | 6239 S MAY ST | COMPLAINT | FAILED | View |
PROVIDE HOT WATER TO FIXTURES | ALL OCCUPIED APARTMENTS (18-29-604-3 THRU 7) (13-196-420) | 6239 S MAY ST | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WATER PIPING | BASEMENT BROKEN WATER PIPES (13-196-120) (18-29-301-4) | 6239 S MAY ST | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | FOR WATER PIPE REPAIRS (18-29-106-2) (13-168-060) | 6239 S MAY ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BASEMENT AND APARTMENTS (18-29-601 2&3) (13-12-100) | 6239 S MAY ST | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | FOR REPAIRS (18-29-106-2) 1(4-332-010-100) | 6239 S MAY ST | COMPLAINT | FAILED | View |
VACANT BUILDING - REGISTER | 6239 S MAY ST | COMPLAINT | CLOSED | View | |
REPAIR INTERIOR WALLS/CEILING | 2ND FLOOR APARTMENT BATHROOM WEST WALL AT CEILING - WATER DAMAGE WITH STRONG SMELL OF A MOLD-LIKE SUBSTANCE. | 6239 S MAY ST | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | ATTIC APARTMENT - FILTHY AND UNSANITARY CONDITIONS, WITH SEVERE MILDEW BUILT-UP ON WALLS AND CEILINGS. | 6239 S MAY ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD AND BASEMENT - ACCUMULATION OF JUNK AND DEBRIS. | 6239 S MAY ST | COMPLAINT | FAILED | View |