PIN: 20074120420000
Property Address: 5246 S HERMITAGE AVE
City - Zip: CHICAGO - 60609
2023 Property Class: 211
2023 Township: 72 - Lake
2023 Neighborhood: 72091
2023 Tax District: 72014
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 106 Violations
Violation Inspector Comments Address Category Status View
SAFE WORKING CONDITIONS FURNACE NOT WORKING 1ST FLOOR 5246 S HERMITAGE AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO OWNERS ID POSTED - NOT OWNER OCCUPIED. 5246 S HERMITAGE AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTORS, FRONT STAIRS, REAR STAIRS, 2ND FLOOR. 5246 S HERMITAGE AVE COMPLAINT FAILED View
DOOR PROJECT INTO PUBLIC WAY 2ND FLOOR FRONT ENTRY DOOR SWINGS OUTWARD. 5246 S HERMITAGE AVE COMPLAINT FAILED View
INSUFFICIENT MEANS OF EGRESS ATTIC APARTMENT HAS ONLY ONE MEANS OF EGRESS, DANGEROUS. 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM 2 STORY WOOD, ENCLOSED REAR PORCH, STRINGERS NOT BOLTED IMPROPER DESIGN, FLOOR JOISTS 25" ON CENTER, MISSING HANGERS, LOOSE RAILINGS. SECTIONS OF PORCH BEING USED FOR LIVING AREA. PLANS AND PERMITS NEEDED. 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING 2ND FLOOR FURNACE ROOM FALLING AND MISSING PLASTER. 5246 S HERMITAGE AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY REAR STAIRS ARE BEING USED FOR STORAGE, DANGEROUS. 5246 S HERMITAGE AVE COMPLAINT FAILED View
PLANS & PERMITS REQUIRED PLANS AND PERMITS FOR REAR PORCH. TO INCLUDE REAR PORCH, BASEMENT AND ATTIC BEING USED FOR DWELLING UNITS. THESE PLANS TO INCLUDE ELECTRICAL AND PLUMBING AND HEATING UNITS THAT WERE INSTALLED ON ALL FLOORS. 5246 S HERMITAGE AVE COMPLAINT FAILED View
REMV OBSTR FROM DRAINAGE SYSTM TUB, SINK, 1ST FLOOR (13-168-120) (18-29-102.3) 5246 S HERMITAGE AVE COMPLAINT FAILED View
SAFE WORKING CONDITIONS 1ST FLOOR UNIT - BROKEN FURNACE. 5246 S HERMITAGE AVE COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG 1ST FLOOR UNIT - NO HOT WATER. 5246 S HERMITAGE AVE COMPLAINT FAILED View
HEAT UNIT ADEQUATELY 1ST FLOOR UNIT - 66. 5246 S HERMITAGE AVE COMPLAINT FAILED View
DEFECTIVE OUTLETS REPAIR DEFECTIVE INOPERABLE OR LOOSE OUTLETS AT REAR COACH HOUSE,REAR BEDROOM GROUND FLOOR AT EAST WALL, GROUND FLOOR AT STAIR TO 1ST FLOOR,GROUND FLOOR 1ST BEDROOM,KITCHEN AT 1ST FLOOR NORTH WALL 5246 S HERMITAGE AVE COMPLAINT FAILED View
DEFECTIVE FIXTURES REPAIR DEFECTIVE INOPERABLE LIGHTING AT GROUND FLOOR BOILER ROOM LOCATED IN 1ST BEDROOM 5246 S HERMITAGE AVE COMPLAINT FAILED View
INSTALL COVERS REPLACE MISSING OUTLET COVER 1ST FLOOR KITCHEN AT SOUTH WALL 5246 S HERMITAGE AVE COMPLAINT FAILED View
CLOSE BOX OPENINGS PROVIDE MISSING BREAKER FILLERS AT PANEL LOCATED AT GROUND FLOOR IN REAR BEDROOM 5246 S HERMITAGE AVE COMPLAINT FAILED View
DEFECTIVE FEEDER SE CABLE SERVICE FEEDER SEVERELY DETERIORATED 5246 S HERMITAGE AVE COMPLAINT FAILED View
CIRCUIT ONE UNIT ONLY 18-27-210.25 PROVIDE PUBLIC PANEL AND METER FOR ALL BUILDING COMMON AREA LOADS 5246 S HERMITAGE AVE COMPLAINT FAILED View
DEFECTIVE POWER SERVICE 5246 S HERMITAGE AVE COMPLAINT FAILED View
FIRE & WATER DAMAGE 5246 S HERMITAGE AVE COMPLAINT FAILED View
SAFE WORKING CONDITIONS REAR COACH HOUSE HEAT NOT SUPPLIED TO BEDROOMS ON GROUND LEVEL 5246 S HERMITAGE AVE COMPLAINT FAILED View
PROV HOT WTR TO ALL FIXTURES NO HOT WATER 5246 S HERMITAGE AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS SMOKE DETECTORS MISSING 5246 S HERMITAGE AVE COMPLAINT FAILED View
CARB MONOX DETECT IN ASSEMBLY CARBON MONOXIDE DETECTORS MISSING 5246 S HERMITAGE AVE COMPLAINT FAILED View
SUPPORT FIXTURES PROPERLY SUPPORT LOOSE LIGHTING AT GROUND FLOOR REAR BEDROOM CEILING 5246 S HERMITAGE AVE COMPLAINT FAILED View
SAFE WORKING CONDITIONS 1ST FLOOR DEFECTIVE FURNACE PER PEOPLE ENERY NOTICE 984922 ISSUED 10/18/07 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS 1ST FLR DEFECTIVE SMOKE DET 5246 S HERMITAGE AVE COMPLAINT FAILED View
RELOCATE SMOKE DETECTOR FRONT STAIRWAY APRX 5-0 BELOW THE CEILING 5246 S HERMITAGE AVE COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. 5246 S HERMITAGE AVE COMPLAINT FAILED View
OPEN TYPE VIOLATION (1) PROVIDE PLANS & PERMIT FOR HEATING SYSTEM ALL 13-32-270, 13-40-140 (2) FURNACE & HOTWATER TANK NOT ALLOWED IN BEDROOM 18-28-918-9.2 (3) REMOVE FLEX DUCT ALL AREA 18-28-603.5.1 (4) PROVIDE RETURN AIR DUCT 18-28-918.2 (5) TEMPERATURE CONTROLS 18-13-803.2.3.1 (6) RETURN AIR NOT ALLOWED FROM KITCHEN, CLOSET, BATH ROOM, TOILET RM, GARAGE MECH RM, OR FURN RM 18-28-918.6 (7) PROVIDE CARBON MONOXIDE DETECTORS IN LIVING SPACE 18-28-711.1 5246 S HERMITAGE AVE COMPLAINT FAILED View
FLUE PIPE CLEARANCE 6"X 1ST FLOOR INTERIOR STAIRWAY,FLUE PIPE PASSES THROUGH STAIRWAY WALLS. 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR BUILDING,WEST ELEVATION,REAR PORCH GRADE TO 1ST FLOOR.4 BY 4 COLUMNS SET ON CONCRETE BLOCKS,LEDGER BOARD IS FACE NAILED ONLY,JOISTS ARE 2 BY 6 FACE NAILED ONLY,RIM JOISTS AREFACE NAILED TO 4 BY 4 SUPPORTS,RAILS ARE 40" HIGH LADDER TYPE LOOSE AND PULLING,STAIR STRINGERS ARE 2 BY 6 WITH ANGLED BLOCKING FOR TREADS,DECKING IS SPLITTING AND ROTTING. PERMIT REQUIRED FOR REPAIRS. 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR REAR BUILDING,EAST ELEVATION,ENTRY STORM DOOR LOOSE AND HANGING. 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPAIR GUTTER & DOWNSPOUT SOUTH ELEVATION,GUTTER AND DOWNSPOUT MISSING SECTION,LOOSE AND HANGING.SIDE GANGWAY WAS CAUTION TAPED OFF. 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING 1ST FLOOR UNIT , KITCHEN CEILING,LOOSE AND SAGGING DRYWALL. 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPAIR FLOOR KITCHEN AND BATHROOM FLOOR LOOSE AND MISSING TILE WITH WEAK AREAS. 5246 S HERMITAGE AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION FRONT BUILDING,NO ENTRY TO BASEMENT AND ATTIC.REAR BUILDING NO ENTRY TO 2ND FLOOR AND ATTIC,TO CHECK OCCUPANCY DETECTORS. 5246 S HERMITAGE AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS REAR ENCLOSED STAIRWAY,MISSING SMOKE DETECTOR, 5246 S HERMITAGE AVE COMPLAINT FAILED View
RELOCATE SMOKE DETECTOR FRONT STAIRWAY,SMOKE DETECTOR IS 3 FEET FROM CEILING. 5246 S HERMITAGE AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID 1ST AND 2ND FLOOR UNITS MISSING CARBON MONOXIDE DETECTORS. 5246 S HERMITAGE AVE COMPLAINT FAILED View
SUPPORT FIXTURES 1ST FLOOR UNIT,CENTER BEDROOM,CEILING LIGHT LOOSE AND HANGING. 5246 S HERMITAGE AVE COMPLAINT FAILED View
STOP LEAKING WATER 1ST FLOOR UNIT ,KITCHEN SINK,LEAKS CAUSING METAL CABINET TO RUST OUT . 5246 S HERMITAGE AVE COMPLAINT FAILED View
REMV OBSTR FROM DRAINAGE SYSTM 1ST FLOOR UNIT,BATHROOM TUB WATER BACKED UP. 5246 S HERMITAGE AVE COMPLAINT FAILED View
MAINTAIN WINDOW ALL ELEVATION ROTTED WINDOW FRAMES 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT STAIRSYSTEM STRINGER NOT ATTACH AND COLLASPING,ROTTED STRINGERS,JOISTS, AND TREADS,LOOSE RAILS,JOISTS NOT CONNECTED TO DECKING BOARDS,BASEMENT NO HANDRAIL OR GUARDRAIL,OVERHANG FIBER GLASS MATERIAL BIG HOLE REQUIRE PERMIT POSTED D&H SIGN ON STAIRSYSTEM FRONT 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS 1ST AT EAST BROKEN PANE 5246 S HERMITAGE AVE COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY BASEMENT SERVICE WALK SPALLING 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPLACE DEFECTIVE PLBG FIXTURE BASEMENT AT BOILER ROOM MISSING PIPES 5246 S HERMITAGE AVE COMPLAINT FAILED View
MAINTAIN WINDOW SASH SASHES WORN AND ROTTED THRU-OUT BUILDING 5246 S HERMITAGE AVE COMPLAINT FAILED View
NO CLOSET/STORAGE UNDER STAIR EXCESSIVE STORAGE UNDER REAR PORCH 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH STRINGERS SUPPORTED BY SCABBED 2X10 STOCK,TOENAIL ONLY,LOOSE RAIL,ROTTED DECKING,HORIZON RAILS,DRYWALL REQUIRE PERMIT 5246 S HERMITAGE AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS PORCH NO SMOKE DETECTOR 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPAIR GUTTER & DOWNSPOUT REAR MISSING DOWNSPOUT AND SECTION OF GUTTER AT SOUTH 5246 S HERMITAGE AVE COMPLAINT FAILED View
EXPOSED WIRING EXPOSED WIRE CEILING BASEMENT D&H 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPLACE D&H PORCH IMMINENTLY DANGEROUS AND HAZARDOUS COACH HOUSE REAR ONE-STORY OPEN WOOD PORCH -(1) ALL WOOD SEVERELY ROTT WITH JOINTS PULLING CREATING LARGE GAPS THAT EXPOSE RUSTED NAILS(2) JOIST CONNECTIONS ARE ONLY FACE NAILED OR TOE NAILED(3) COLUMNS BEAR ON CONCRETE BLOCKS WITH UNKNOWN FOUNDATIONS(4) DECK CONNECTION AT BUILDING HAS FAILED AND IS PARTIALLY COLLAPSED(5) STRINGERS CONNECTIONS TO POST, COLUMNS AND RIM JOIST ARE VERY WEAK AND ONLY FACE NAILED OR TOE NAILED(6) BEAM-TO-COLUMN CONNECTIONS ARE WEAK, HAVE WIDE OPEN GAPS AND ARE SEPARATING WITH ROTTED BROKEN WOOD(7) HAND AND GUARDRAILS ARE WEAK, OVERSPANNED AND SAGGING(8) DRAWINGS ARE REQUIRED TO OBTAIN THE REPLACEMENT PERMIT 5246 S HERMITAGE AVE COMPLAINT FAILED View
DEFECTIVE LIGHTING SERVICE OPEN PANEL FOR BASEMENT UNIT D&H 5246 S HERMITAGE AVE COMPLAINT FAILED View
COVER OUTLETS AND JBS OPEN BOXES BASEMENT CEILING 5246 S HERMITAGE AVE COMPLAINT FAILED View
INSTALL ILLUMINATION ADD LIGHTING TO FRONT AND REAR ENTRIES 5246 S HERMITAGE AVE COMPLAINT FAILED View
SUPPLEMENTAL GROUND REPAIR SUPPLEMENTAL GROUND 5246 S HERMITAGE AVE COMPLAINT FAILED View
CONTINUITY OF RACEWAY CONNECT CONDUCTS TO SERVE PANEL 5246 S HERMITAGE AVE COMPLAINT FAILED View
COVER OUTLETS AND JBS OUTLETS COVERS NEEDED BASEMENT KITCHEN 5246 S HERMITAGE AVE COMPLAINT FAILED View
MULTIPLE CONDUCTOR TERM MULIT TERM ON BREAKER 5246 S HERMITAGE AVE COMPLAINT FAILED View
EXPOSED WIRING EXPOSED WIRES KITCHEN CEILING D&H 5246 S HERMITAGE AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# FRONT ELEVATION OWNER'S I.D. SIGN NOT POSTED 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT PORCH STRINGERS RPTTED,SCABBED,LOOSE TREADS,UNEVEN STEPS,LEADGER BOARD FOR LANDINGS MISSING BOLTS,FLOOR JOISTS MISSING JOIST HANGERS. 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS FRONT ELEVATION 1ST FLOOR WINDOW BROKEN PANE 5246 S HERMITAGE AVE COMPLAINT FAILED View
MAINTAIN WINDOW ALL ELEVATIONS WINDOWS ROTTED SASHES 5246 S HERMITAGE AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO INTERIOR TO VERIFY DETECTORS. 5246 S HERMITAGE AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR PROVIDE PLANS AND PERMIT FOR FRONT PORCH REPAIRS 5246 S HERMITAGE AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS BASEMENT AND ATTIC SMOKE DETECTOR MISSING 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS !ST FLOOR SMOKE DETECTOR NOT WORKING 5246 S HERMITAGE AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID ENTIRE HOUSE NO CARBON MONOXIDE DETECTOR INSTALLED 5246 S HERMITAGE AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR PROVIDE PLANS AND PERMIT. 5246 S HERMITAGE AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING ¿ NO ENTRY, UNVERIFIED DETECTORS AND CONDITIONS 5246 S HERMITAGE AVE COMPLAINT HOLD View
POST OWNER/MANAGERS NAME/# BUILDING OWNER ID NOT POSTED. 5246 S HERMITAGE AVE COMPLAINT HOLD View
FILE BLDG REGISTRATION BUILDING NOT REGISTERED FROM 1990 TO 2017 5246 S HERMITAGE AVE COMPLAINT HOLD View
REPAIR EXTERIOR STAIR FRONT STAIRS GRADE TO BASEMENT MISSING HANDRAIL. 5246 S HERMITAGE AVE COMPLAINT HOLD View
REPAIR WINDOW SILLS FRONT 1ST AND 2ND FLOOR WOOD WINDOW SILLS ROTTED2).BASEMNT WINDOW SILLS OPEN MORTAR JOINTS. 5246 S HERMITAGE AVE COMPLAINT HOLD View
REPLACE D&H PORCH FRONT PORCH GRADE TO 1ST FLOOR 1)COLUMNS ARE SITTING ON HALF THE FOUNDATION.2)JOIST NAILED TO HEADER 2X6 SCAB TOGETHERE IN 7'8" SPAN.3)STRINGERS AND GUARDRILS NAILED TO HEADERS.COLUMNS AND WALL.4)TREADS LOOSE STRINGERS AND DECKING ROTTED..6)IRON GUARD RAILS LOOSE AND NOT ANCHORED TO WALL..REAR PORCH GRADE TO 1ST FLOOR 1)6X6 AND 4X4 COLUMNS LEANIG AND ERECTED ON BLOCKS.2)JOISTED NAILED TO HEADERS.3)1ST FLOOR GUARD RAILS LEANING ROTTED READY TO FALL..4)GUARD RAILS MISSING PICKETS THROUGHOUT5)GUARDRAILS AND STRINGERS NAILED TO HEADERS, COLUMNS AND WALL.PERMIT REQUIRED FOR REPAIRS FOR FRONTAND REAR PORCH,. 5246 S HERMITAGE AVE COMPLAINT HOLD View
REPLCE WINDOW PANES, PLEXGLAS REAR 2ND FLOOR BROKEN GLASS PANE. 5246 S HERMITAGE AVE COMPLAINT HOLD View
STOP/REMOVE NUISANCE REAR YARD HIGH WEEDS AND DEBRIS THROUGHOUT. 5246 S HERMITAGE AVE COMPLAINT HOLD View
REPAIR PORCH SYSTEM REAR BUILDING REAR PORCH LEDGER BOARDS MISSING MISSING BOLTS,STRINGERS NO BOLTS,IMPROPER DESIGN,FLOOR JOISTS 25"OC,MISSING HANGERS,RAILINGS LOOSE AND MISSING PICKETS. 5246 S HERMITAGE AVE COMPLAINT FAILED View
DEFECTIVE DISTRIBUTION EXPOSED BUS DETAIL AT PANEL. (COACH HOUSE) DANGEROUS AND HAZARDOUS 5246 S HERMITAGE AVE COMPLAINT FAILED View
EXPOSED WIRING FIXTURES AT REAR COACH HOUSE. DANGEROUS AND HAZARDOUS 5246 S HERMITAGE AVE COMPLAINT FAILED View
DEFECTIVE METER EQUIPMENT METER BOX AND COVER ARE DAMAGED (COACH HOUSE) DANGEROUS AND HAZARDOUS 5246 S HERMITAGE AVE COMPLAINT FAILED View
DEFECTIVE SERVICE SERVICE RISER PULLING AWAY FROM BUILDING (COACH HOUSE) DANGEROUS AND HAZARDOUS 5246 S HERMITAGE AVE COMPLAINT FAILED View
SERVICE DROP OUT OF REACH SERVICE LATERAL IS WITHIN REACH FROM REAR PORCH (COACH HOUSE) DANGEROUS AND HAZARDOUS 5246 S HERMITAGE AVE COMPLAINT FAILED View
GROUNDING RECEPTACLES RECEPTACLES WIRED IN FREE AIR. (COACH HOUSE) DANGEROUS AND HAZARDOUS. A PERMIT IS REQUIRED TO CORRECT ALL VIOLATIONS. 5246 S HERMITAGE AVE COMPLAINT FAILED View
HEAT UNIT ADEQUATELY 1ST FLOOR 62.4 DEGREES 5246 S HERMITAGE AVE COMPLAINT FAILED View
SUPPORT FIXTURES 2ND FLOOR BEDROOM HANGING LIGHT FIXTURE. 5246 S HERMITAGE AVE COMPLAINT FAILED View
RESET LOOSE FIXTURE TOILET, 2ND FLOOR (18-29-402.1.1) 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPLACE DEFECTIVE WASTE PIPING 1ST FLOOR DEF. WASTE (18-29-301.3) KITCHEN SINK 5246 S HERMITAGE AVE COMPLAINT FAILED View
TENANT ACCESS TO SERVICE 5246 S HERMITAGE AVE COMPLAINT FAILED View
OPEN TYPE VIOLATION PROVIDE ENTRY FOR 311 INSPECTION (13-12-100,13-20-290,13-32-270) 5246 S HERMITAGE AVE COMPLAINT FAILED View
HEAT UNIT ADEQUATELY 1ST FLR TEMP 67F AT 3:00 PM 5246 S HERMITAGE AVE COMPLAINT FAILED View
CHIMNEY HEIGHT NORTH ELEVATION,METAL CHIMNEY FLUES (2), HEIGHT STOPS AT THE GUTTERS . 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM EAST ELEVATION FRONT PORCH FIBER GLASS PANEL ROOF BROKEN AND MISSING SECTIONS. 5246 S HERMITAGE AVE COMPLAINT FAILED View
EXPOSED WIRING REAR ENCLOSED EXPOSED WIRING 5246 S HERMITAGE AVE COMPLAINT FAILED View
DEFECTIVE POWER SERVICE SERVICE DISCONNECT MORE THAN 5' FROM ENTRY 5246 S HERMITAGE AVE COMPLAINT FAILED View
DEFECTIVE OUTLETS DEFECTIVE OUTLETS AND SWITCHES THROUGHOUT BASEMENT 5246 S HERMITAGE AVE COMPLAINT FAILED View
UNAPPROVED CORDS REMOVE ROMEX IN REAR CEILING UNDER PORCH 5246 S HERMITAGE AVE COMPLAINT FAILED View
SECURE RACEWAY SUPPORT CONDUITS AT SERVICE PANEL 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPAIR ROOF COACH HOUSE ROOF - WORN UNDERLAYMENT WITH SHINGLES MISSING 5246 S HERMITAGE AVE COMPLAINT FAILED View
MAINTAIN WINDOW COACH HOUSE WINDOWS - FRAMES AND SASHES SEVERELY ROTTED WITH MANY CRACKED, BROKEN AND MISSING GLASS PANES - SOME BOARDED WINDOW OPENINGS 5246 S HERMITAGE AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL COACH HOUSE EXTERIOR WALL SHINGLES - SEVERELY WORN AND PAST THEIR LIFE CYCLE USEFULNESS 5246 S HERMITAGE AVE COMPLAINT FAILED View