Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
DEFECTIVE POWER SERVICE | DEFECTIVE SERVICE TO 2ND FLOOR APARTMENT | 7816 S RIDGELAND AVE | COMPLAINT | FAILED | View |
CIRCUIT ONE UNIT ONLY | RESOLVE MIXED CIRCUIT ISSUES THROUGHOUT BUILDING BASEMENT APARTMENT HAS NO PANEL OR METER PROVIDE PUBLIC AREA PANEL AND METER FOR ALL PUBLIC AREAS OF BUILDING | 7816 S RIDGELAND AVE | COMPLAINT | FAILED | View |
TENANT ACCESS TO SERVICE | PROVIDE ACCESS TO ELECTRICAL PANELS TO ALL TENANTS | 7816 S RIDGELAND AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | REPAIR INOPERABLE RECEPTACLE OUTLETS AT 2ND FLOOR LIVING ROOM AT NORTH,EAST AND WEST WALLS A PERMIT IS REQUIRED FOR THE CORRECTION OF ALL ELECTRICAL VIOLATIONS | 7816 S RIDGELAND AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 4X4 COLUMN UNDERSIZED NO JOIST HANGERS IMPROPER FOUNDATIONS ON BLOCKS LOOSE DAMAGED GUARDRAILS AND HANDRAILS WINDERS OVERCUT SUPPORTED BY SCABBED 4X4 AT FRONT MISSING PICKETS HANDRAILS TOO LOW 42' REQUIRE CRACKED STRINGERS | 7816 S RIDGELAND AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLANS AND PERMITS TO REPAIR REBUILD PORCH | 7816 S RIDGELAND AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | ARRANGE FOR INTERIOR INSPECTION REGARDING OCCUPANCY OF BASEMENT | 7816 S RIDGELAND AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | INSTALL SMOKE DETECTORS FRONT HALL | 7816 S RIDGELAND AVE | COMPLAINT | PASSED | View |
REPAIR/REPLACE SMOKE DETECTORS | OUT OF SERVICE SMOKE DETECTOR APARTMENT #2 | 7816 S RIDGELAND AVE | COMPLAINT | PASSED | View |
FILE BLDG REGISTRATION | FILE REGISTRATION WITH DEPARTMENT OF BUILDING | 7816 S RIDGELAND AVE | COMPLAINT | PASSED | View |
DEFECTIVE OUTLETS | 18-27-110.2 2ND FLOOR | 7816 S RIDGELAND AVE | COMPLAINT | FAILED | View |
TENANT ACCESS TO SERVICE | 18-27-230.70 | 7816 S RIDGELAND AVE | COMPLAINT | FAILED | View |
CIRCUIT ONE UNIT ONLY | 18-27-210.25 PROVIDE PUBLIC PANEL AND METER FOR ALL COMMON AREA BUILDING LOADS | 7816 S RIDGELAND AVE | COMPLAINT | FAILED | View |
DEFECTIVE LIGHTING SERVICE | 18-27-230.2 | 7816 S RIDGELAND AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | DANGEROUS AND HAZARDOUS ONE-STORY BRICK GARAGE WITH HIP ROOF CONSTRUCTION -(1) ROOF COMPLETELY COLLAPSED INTO THE GARAGE WITH ROOF RAFTERS PUSHING OUT ON THE NOW UNSUPPORTED WALLS(2) EAST WALL TOP HALF - SUBSTANTIALLY LEANING OUTWARD OVER THE REAR YARD(3) SOUTH WALL FRONT WYTHE AT THE TOP - MULTIPLE ROWS OF BRICK MISSING(4) DRAWINGS ARE REQUIRED TO OBTAIN THE REPAIR OR REPLACEMENT PERMIT - DEMOLITION PERMIT REQUIRED TO DEMOLISH | 7816 S RIDGELAND AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | (1) FRONT ELEVATION NORTHEAST PARAPET CORNER OF BAY - WIDE OPEN BRICK STEP CRACK(2) REAR ELEVATION VARIOUS LOCATIONS - WASHED OUT BRICK MORTAR JOINTS(3) REAR ELEVATION NORTH END ABOVE THE FIRST AND SECOND FLOOR WINDOW - STEP CRACKS WITH UNALIGNED BRICK AT ARCHES(4) PERMIT REQUIRED FOR REPAIRS | 7816 S RIDGELAND AVE | COMPLAINT | FAILED | View |
CHIMNEY | SOUTH SIDE OF THE SOUTH CHIMNEY - LOOSE AND MISSING BRICK | 7816 S RIDGELAND AVE | COMPLAINT | FAILED | View |