The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLANS AND PERMIT FOR PORCH REPAIRS. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
PARAPET | PARAPET WALL WEST ELEVATION LOOSE AND DAMAGED, SPALLING BRICK. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO INTERIOR INSPECTION FOR DETECTORS AND POSSIBLE ROOF DECK. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH - BEAMS NOT STRAPPED TO COLUMNS, NO BOLTS - COLUMN LAPP JOINTS, NO JOIST HANGERS FOR LANDING JOISTS, SOUTH EAST 6X6 SIGNIFICANT AND CRACK AT FIRE CUT ON 1, IMPROPER BEAM/COLUMN CONNECTIONS, UNDERSIZED JOIST AND SOUTH HEADER BEAMS, DEFLECTING HANDRAILS. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | RUSTING LINTELS ALL ELEVATIONS. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | REAR BASEMENT STAIRS NO HAND RAIL. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | ROTTING SIDING AND FRAMING REAR PVC DOWNSPOUT ENCLOSURE, WEST ELEVATION WASHED OUT MORTAR SPALLING BRICK. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
PROVIDE DEADLOCK FOR ENTRANCE | REAR BASEMENT DOORS NO LATCH/LOCK. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST ID. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | BASEMENT/LAUNDRY ROOM- EXPOSED FLOOR JOISTS. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | REAR ENTRY TO BASEMENT - FOUNDATION/ RETAINING WALL FRACTURED. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
CHIMNEY | EAST ELEVATION/SOUTH CHIMNEY- SPALLING BRICKS AND WASHED OUT MORTAR. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | EAST AND WEST ELEVATION/WINDOW SILLS- WASHED OUT MORTAR. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO GARAGE OR RESTORE THE BUILDING TO THE ORIGINAL STATE. DWELLING UNIT INSTALLED ABOVE GARAGE. ROOFTOP DECK INSTALLED OVER REAR PORCH. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES [INCLUDING ELECTRIC AND PLUMBING] INSTALLED OVER GARAGE WITHOUT A PERMIT. ROOF TOP DECK INSTALLED OVER REAR PORCH. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
INT WALL/CEILING PEELING PAINT | BASEMENT UNIT (WEST SIDE OF BASEMENT)- BATHROOM WALLS- MILDEW, KITCHEN WALLS AND CEILING- WATER DAMAGE, FLAKING PAINT. HEAT DAMAGE ALSO- NEXT TO KITCHEN STOVE. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
EXPOSED WIRING | FRONT BASEMENT STAIRWELL- ELECTRIC WIRES HANGING FROM CEILING. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
SUPPORT FIXTURES | FRONT BASEMENT STAIRWELL CEILING LIGHT FIXTURE- HANGING SOCKET, EXPOSED WIRES. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
STOP LEAKING WATER | REAR BASEMENT LAUNDRY, ELECTRIC, BOILER ROOM- WATER ON FLOOR, ACTIVE LEAK. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | REAR BASEMENT LAUNDRY, BOILER ROOM- SMOKE DETECTOR NOT IN SERVICE. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | NO CARBON MONOXIDE DETECTOR- BOILER ROOM. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | EAST PORTION OF BASEMENT- NO ENTRY. NO RESPONSE UNITS 1-3. UNABLE TO VERIFY DETECTORS AND OCCUPANCY. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
REPAIR DOOR FRAME, MULLION | BASEMENT UNIT FRONT DOOR- FRAME CRACKED/ SPLIT. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
REPAIR FLOOR | FRONT ENTRY FLOOR TILES- FRACTURES. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
MICE/RODENTS | FRONT BUILDING/ FRONT BASEMENT APARTMENT- RODENT INFESTATION. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
WINDOW OPEN EASILY, STAY OPEN | FRONT BUILDING/ FRONT BASEMENT APARTMENT/ WINDOWS THRUOUT-INOPERABLE, FALLS OUT OF FRAMES. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
INSTALL COVERS | FRONT BUILDING/ FRONT BASEMENT APARTMENT FRONT ROOM CEILING- OPEN BOX, WITH EXPOSED WIRES. FRONT BUILDING/REAR EXTERIOR PORCH- OPEN BOX WITH EXPOSED WIRES. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT BUILDING/ FRONT EXTERIOR DOOR- PEELING VENEER. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
RESTORE EXIT AND EM | FRONT BUILDING/ FRONT INTERIOR STAIRWAY- EMERGENCY LIGHTS OUT OF SERVICE. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | FRONT BUILDING/SOUTH ELEVATION EXTERIOR WALL- SECTIONS OF SIDING MISSING, WITH EXPOSED PLYWOOD. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | FRONT BUILDING- NOT REGISTERED FROM 2010 THRU 2014. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | REAR RESIDENTIAL GARAGE/ 2ND FLOOR DWELLING UNIT HAS BEEN BUILT- NO PLANS SUBMITTED, NO PERMIT OBTAINED. PERMIT SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
INSPECT CONSTRUCTION WORK | PERMIT #100308074 ISSUED ON 09/15/2009 FOR: REPAIRS TO EXISTING OPEN WOOD PORCH STRUCTURE, TO BRING UP TO NEW CODE. PLANS AND PERMIT NOT AVAILABLE FOR INSPECTORS REVIEW AT TIME OF INSPECTION. PERMIT SUBJECT TO FIELD INSPECTION AND APPROVAL. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
REPAIR FLOOR | FRONT BUILDING FRONT ENTRYWAY FLOOR- BROKEN TILES. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
REPAIR DOOR FRAME, MULLION | FRONT BUILDING/ FRONT BASEMENT APARTMENT ENTRY DOOR FRAME- SECTIONS MISSING, WITH LATCH OUT OF SERVICE. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
INT WALL/CEILING PEELING PAINT | FRONT BUILDING/ FRONT BASEMENT APARTMENT/ WALLS AND CEILINGS THRUOUT- MILDEW BUILDUP. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
INT WALL/CEILING CHIP PLASTER | FRONT BUILDING/ FRONT BASEMENT APARTMENT/ CEILINGS THRUOUT- SPALLING PLASTER. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
DEFECTIVE FIXTURES | FRONT BUILDING/ FRONT BASEMENT APARTMENT/ LIGHT FIXTURES THRUOUT- MISSING COVERS. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
RESET LOOSE FIXTURE | FRONT BUILDING/ FRONT BASEMENT APARTMENT TOILET- LOOSE, PULLING, AND LEAKING WATER AT BASE. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
REPLACE DEFECTIVE FAUCET | FRONT BUILDING/ FRONT BASEMENT APARTMENT BATHTUB- FAUCET MISSING, WITH IRON PIPE EXTENDING FROM WALL. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
REPAIR DOOR, INT. | FRONT BUILDING/ FRONT BASEMENT APARTMENT BATHROOM DOOR- DOESN'T CLOSE [HITTING AGAINST TOILET]. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
INSECTS | FRONT BUILDING/ FRONT BASEMENT APARTMENT- ANT INFESTATION. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
REPAIR SCREENS | FRONT BUILDING/ WINDOWS THRUOUT- TORN AND MISSING SCREENS. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD AREA/ ACCUMULATION OF DEBRIS- PILES OF BRICKS. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
EXPOSED WIRING | FRONT BUILDING/ BASEMENT STAIRWAY- EXPOSED WIRES. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
REPAIR OR REPLACE | FRONT BUILDING/ FRONT BASEMENT APARTMENT/ CEILING HEATING VENTS- LOOSE AND HANGING DOWN. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | FRONT BUILDING/ REAR BASEMENT APARTMENT- NO RESPONSE, AND GARAGE 2ND FLOOR DWELLING UNIT- ENTRY REFUSED BY OCCUPANT. UNVERIFIED DETECTORS, CONDITIONS, AND OCCUPANCY. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | FRONT BUILDING/ REAR BASEMENT APARTMENT- NO RESPONSE, AND GARAGE 2ND FLOOR DWELLING UNIT- ENTRY REFUSED BY OCCUPANT. UNVERIFIED DETECTORS, CONDITIONS, AND OCCUPANCY. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
COVER OUTLETS AND JBS | OPEN JUNCTION, SWITCH, AND OUTLET BOXES THROUGHOUT FRONT STAIRWELL. | 2033 W MORSE AVE | COMPLAINT | FAILED | View |
ILLUMINATE PUBLIC STAIR/HALL | EMERGENCY LIGHT NOT OPERATING FRONT INTERIOR STAIRWELL AT 3. | 2033 W MORSE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY UNITS 1,2, AND BASEMENT. UNABLE TO VERIFY DETECTORS. | 2033 W MORSE AVE | COMPLAINT | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING - NO RESPONSE. UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, REAR COACH HOUSE, AND SPECIFICALLY BASEMENT UNIT FOR COMPLAINT OF MISSING DETECTORS AND ELECTRICAL PROBLEMS. UNVERIFIED DETECTORS AND CONDITIONS. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | SOUTH - BBQ GRILLS ON ALL DECKS OF REAR WOODEN PORCH; PROPANE TANKS STORED ON 2ND FOOR; OBSTRUCTING PASSAGEWAY | 2033 W MORSE AVE | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | SOUTH - BBQ GRILLS, FURNITURE, CHAIRS ON ALL DECKS OF REAR WOODEN PORCH OBSTRUCTING EXITWAY | 2033 W MORSE AVE | PERIODIC | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | SOUTH - BRICKS, CRATES STORED UNDERNEATH ENCLOSED AREA OF REAR PORCH. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
COVER OUTLETS AND JBS | REAR BASEMENT ELECTRIC ROOM- OPEN BREAKER BOXES, OPEN JUNCTION BOXES. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | NOT REGISTERED 2015-2016 | 2033 W MORSE AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH - REAR PORCH/FRONT BUILDING - FOUNDATION STATUS UNKNOWN; 6X6 COLUMNS TWISTING; TREADS SPLITTING AND SPLINTERED FROM GRADE TO 3RD FLOOR; LOOSE DECKBOARD AT LANDING BETWEEN 1ST & 2ND FLOOR, UNSECURED. PERMIT REQUIRED TO REPAIR REAR PORCH. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
PARAPET | EAST AND WEST ELEVATION /PARAPET - SPALLED BRICKS, WITH WASHED OUT MORTAR. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
ROOF DRAINAGE FLOOD ADJCNT LOT | GARAGE ROOF-TOP DWELLING UNIT - WATER RUN OFF TO ADJACENT PROPERTY. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
ABANDONED REFRIGERATOR | REAR YARD - ABANDONED REFRIGERATOR. | 2033 W MORSE AVE | PERIODIC | FAILED | View |
DEMO DEBRIS | REAR YARD - CONSTRUCTION MATERIAL SCATTERED THROUGHOUT. | 2033 W MORSE AVE | PERIODIC | FAILED | View |