Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR STAIR | FRONT EXTERIOR WOOD STAIR- CUPPED, WARPED TREADS, SPLIT TREADS, LOOSE AND DEFLECTING RAILS. STRINGERS AND RAILS FASTENED WITH NAILS ONLY. LANDING 2X4 JOISTS ANCHORED WITH NAILS ONLY, SHIFTED. LANDING BEAMS TOE NAILED TO BUILDING AND LEDGER. STRINGERS SEATED ON A CONCRETE SLAB WITH ERODED SOIL AND VOIDS BENEATH. FRONT CONCRETE STAIRS - FRACTURED TREADS, NO HAND RAIL. REAR CONCRETE STAIR TO ALLEY- NO HAND RAIL, MISSING CONCRETE TREADS, FRACTURES. REAR WOOD STAIRS- LOOSE AND DEFLECTING RAILS. RAILS AND STRINGERS WITH MOVEMENT/ LATERAL SWAY. STRINGERS AND RAILS ANCHORED WITH NAILS ONLY. LEDGER ANCHORED WITH NAILS ONLY. SPLIT TREADS. GARAGE STAIRS- DEFLECTING RAILS. MISSING SECTIONS OF GUARD RAIL. GUARD RAIL ONLY 35'' IN HEIGHT. ROTTING PRESS BOARD DECKING. NO FOOTINGS FOR COLUMNS. BEAMS AND COLUMNS ANCHORED WITH NAILS AND /OR SCREWS ONLY. FOR 1 FRONT AND 2 REAR EXTERIOR WOOD STAIRS OBTAIN PERMIT TO REPLACE. BL00831 | 2059 N BINGHAM ST | COMPLAINT | CLOSED | View |
STOP/REMOVE NUISANCE | REAR OF PROPERTY- GARBAGE, BAGS, BRUXH, ROTTING WOOD.BL00831 | 2059 N BINGHAM ST | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- NO RESPONSE. UNABLE TO VERIFY DETECTORS. BL00831 | 2059 N BINGHAM ST | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | FRONT STAIRS AND REAR PORCH - MISSING SMOKE DETECTOR. | 2059 N BINGHAM ST | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | 1ST FLOOR APT. - VENTLESS GAS SPACE HEATER. | 2059 N BINGHAM ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | EAST SERVICE WALK - SECTION MISSING AND CRACKED CONCRETE. | 2059 N BINGHAM ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR TWO STORY ENCLOSED PORCH, HAS BEEN ALTERED, A ROOM HAS BEEN BUILT IN THE 1ST FLOOR AND THE STAIRS GRADE TO 2ND HAVE BEEN ALTERED AND ARE ONLY 30" WIDE, MISSING HANRAILS. PLAN AND PERMIT IS REQUIRED TO RESTORE PORCH TO THE ORIGINAL CONDITION. | 2059 N BINGHAM ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT AND REAR NEW EXTERIOR STAIR GRADE TO 1ST HAVE BEEN BUILT WITHOUT A PERMIT; STRINGERS ARE IMPROPERLY CUT, STAIRS ARE NOT LEVEL, STRTRINGERS AND RAILING POSTS ARE FASTENED WITH NAILS ONLY; FRONT EXTERIOR STAIRS, STRINGERS RESTING ON CONCRETE SLAB WITH VOIDS UNDER; REAR EXTERIOR STAIRS, HANDRAILS ARE LOOSE AND OUT OF PLUMB. PERMIT REQUIRED FOR FRONT AND REAR EXTERIOR STAIRS REPAIRS.REAR EXTERIOR STAIRS YARD TO ALLEY - GUARD RAILINGS ARE LOOSE AND PULLING WITH BALUSTERS APROX. 6" APART.FRONT CONCRETE STAIRS, SIDEWALK TO PROPERTY SERVICE WALK -FRACTURED TREADS. | 2059 N BINGHAM ST | COMPLAINT | FAILED | View |
REPAIR / REBUILD SHED | GARAGE SERVICE DOOR- ROTTING AND DELAMINATING. BL00831 | 2059 N BINGHAM ST | COMPLAINT | CLOSED | View |