The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PLANS & PERMITS REQ - CONTRCTR | NO PLANS OR PERMIT ON RECORD FOR CONVERTING SINGLE FAMILY HOUSE INTO 2 UNITS.WRITTEN IN ERROR | 4701 W FULTON ST | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | BUILT A NEW FRAME TWO CAR GARAGEPERMIT#100809828, ISSUED:3.19.19 | 4701 W FULTON ST | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | STOP ALL WORK ON PREMISES UNTIL PLANS ARE APPROVED AND PERMIT IS OBTAINEDSECTION 12-080, 13-32-035. | 4701 W FULTON ST | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | THERE SHOULD BE A LANDING AT FRONT AND REAR EXITS IN THE DIRECTION OF TRAVEL.13-160-300 STAIRWAYS ¿ TREADS AND RISERSWINDERS SHALL NOT BE PERMITTED IN STAIRS REQUIRED AS EXITS EXCEPT IN SINGLE-FAMILY AND TWO-FAMILY DWELLINGS. THE WIDTH OF A TREAD OF A WINDER MEASURED AT A DISTANCE OF 18 INCHES FROM THE INSIDE RAILING SHALL BE NOT LESS THAN NINE INCHES NOR LESS THAN THE TREADS OF THE FLIGHT BELOW OR ABOVE THE WINDING SECTION. THE LENGTH OF A LANDING IN THE DIRECTION OF TRAVEL SHALL BE NOT LESS THAN THE WIDTH OF THE STAIRS, BUT NEED NOT EXCEED FOUR FEET IN A STAIR OF ANY WIDTH.THE REQUIRED HEADROOM IS:13-160-350 STAIRWAYS ¿ HEADROOM. IN RESIDENTIAL UNITS, STAIRWAYS SERVING NOT MORE THAN TWO DWELLING UNITS SHALL HAVE A CLEAR HEADROOM OF NOT LESS THAN SIX FEET EIGHT INCHES. IN ALL OTHER OCCUPANCIES THE CLEAR HEADROOM SHALL BE NOT LESS THAN SEVEN FEET.HANDRAILS AND GUARDRAILS SHOULD COMPLY WITH:13-52-100 THRUSTS ON HANDRAILS AND GUARDS. STAIRWAY, PORCH, DECK AND BALCONY RAILING, BOTH EXTERIOR AND INTERIOR, SHALL BE DESIGNED TO RESIST A SIMULTANEOUS VERTICAL AND HORIZONTAL THRUST OF 50 LBS./FT. (POUNDS-FORCE, PER LINEAR FOOT) APPLIED AT THE TOP OF THE RAILING OR A CONCENTRATED LOAD OF 200 LBS./FT. IN ANY DIRECTION, WHICHEVER PRODUCES THE GREATEST STRESS. FOR ONE- AND TWO-FAMILY DWELLING UNITS, A THRUST OF 20 LBS./FT. MAY BE USED INSTEAD OF 50 LBS./FT. FOR INTERIOR STAIR BALUSTERS OR WALL-MOUNTED INTERIOR HANDRAILS ONLY.FRONT STAIRWELL - FIRST FLOOR AND ATTIC DOORS SHOULD COMPLY WITH:15-8-180 PROTECTION OF OPENINGS IN RESIDENTIAL UNITS NOT EXCEEDING THREE STORIES IN HEIGHT, OPENINGS IN THE ENCLOSURES OF STAIRWAYS SERVING NOT MORE THAN FOUR DWELLING UNITS IN ANY FLOOR MAY BE PROTECTED WITH DOORS NOT LESS FIRE-RESISTANT THAN SOLID WOOD DOORS ONE-AND-THREE-FOURTHS-INCHES THICK, AND SHALL BE EQUIPPED WITH APPROVED SELF-CLOSING DEVICES | 4701 W FULTON ST | COMPLAINT | FAILED | View |