The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
STOP ODORS RPR DFT SEWAGE SYS | 1 & 2 FLOOR | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | 1 & 2 FLOOR | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
EXPOSE FOR INSPECT APPROVAL | 4513 S LAFLIN ST | COMPLAINT | FAILED | View | |
RMV PLBFIX INSTALLD W/0 PERMIT | 4513 S LAFLIN ST | COMPLAINT | FAILED | View | |
ENGAG LIC & BOND PLMBNG CNTRC | 4513 S LAFLIN ST | COMPLAINT | FAILED | View | |
REPLACE HOUSE DRAIN PIPING | 4513 S LAFLIN ST | COMPLAINT | FAILED | View | |
ARRANGE FOR REINSPECTION REGAR | 4513 S LAFLIN ST | COMPLAINT | FAILED | View | |
PLANS & PERMITS REQ - CONTRCTR | INTERIOR AND EXTERIOR ALTERATION TO 2 UNIT BLDG CONSTRUCTED NEW REAR OPEN WOOD STAIRS GRADE TO 2ND FLOOR AND NEW PARTITIONS REAR OPEN 2 STORY PORCH & STAIR SYSTEM WAS POORLY CONSTRUCTED RENDERING IT DANGEROUS | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
NO PERMIT WIRING | CONSTRUCTION OF 2 FLAT FRAME BUILDING WITHOUT PROPER PLANS AND PERMITS | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | REMOVE DISCONNECTS FROM 1ST FLOOR APARTMENT,INSTALL IN LOCATION ACCESSIBLE TO ALL TENANTS 18-27-230.70 | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PROVIDE BONDING BUSHINGS AT LOAD SIDE OF METERING 18-27-250.92 & 94 | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | REMOVE DRYWALL TO PROPERLY CONDUIT INSPECTION OF PIPE AND WIRING AT 1ST AND 2ND FLOOR 13-12-170 | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
CIRCUIT ONE UNIT ONLY | PROVIDE PUBLIC AREA PANEL AND METER | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
DEFECTIVE POWER SERVICE | REPAIR SHORT CIRCUIT AT LAUNDRY ROOM/WATER HEATER AREA LIGHTING | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PROVIDE GROUND FOR 2ND FLOOR PANEL AND DISCONNECT PROVIDE ACCESS TO MAIN WATER GROUND CONNECTION 18-27-250.30 & 50 | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNERS ID POSTED NOT OWNER OCCUPIED | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMITS PLANS FOR PERMITS TO ERECT A 2 STORY WOOD FRAME HOUSE AT REAR OF PROPERTY. | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIRS MISSING HANDRAILS | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTOR | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTORS | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR STAIRS TO 2ND FLOOR NO JOIST HANGERS AT 2ND FLOOR LANDING, INSIDE STRINGER NAILED TO SIDING, LEDGER BOARD NOT BOLTED, 4X4 COLUMNS SITTING ON CONCRETE WALK WITH ONE COLUMN SWINGING FREELY | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | AT REAR BUILDING GRADE, STRUCTURE WALL NOT SITTING ON FOUNDATION, LARGE GAPS SHOWING. | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
SUBMIT FOR APPROVAL PLANS | 4513 S LAFLIN ST | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 4513 S LAFLIN ST | COMPLAINT | CLOSED | View | |
WATCHMAN | 4513 S LAFLIN ST | COMPLAINT | CLOSED | View | |
POST OWNER NAME OF VACNT BLDG | 4513 S LAFLIN ST | COMPLAINT | CLOSED | View | |
FILE BLDG REGISTRATION | 4513 S LAFLIN ST | COMPLAINT | CLOSED | View | |
PLANS & PERMITS REQ - CONTRCTR | BUILDING A NEW TWO STORY FRAME BUILDING UP TO PROPERTY LINE ON NORTHSIDE EXTERIOR WALLS BUILT WITH ORIENTED STRANDED BOARD | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | STOP WORK UNTIL PERMIT IS OBTAINED SECTION 13-12-080, 13-32-035 | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | STOP ALL WORK UNTIL BUILDING PERMIT IS OBTAINED 13-32-035, 13-12-080 | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | FOR INTERIOR ALTERATIONS 1ST & 2ND FLOORS 13-12-050, 13-32-010, 13-32-130 | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
RMV OBSTRN FROM HSE DRAIN PIPE | 4513 S LAFLIN ST | COMPLAINT | FAILED | View | |
SEE INSPECTOR COMMENTS | PROVIDE GFCI'S PROTECTION AT ALL REQUIRED LOCATIONS 18-27-210.8 | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
SUBMIT PLANS FOR PLUMBING PRMT | 4513 S LAFLIN ST | COMPLAINT | FAILED | View | |
OPEN TYPE VIOLATION | STOP ALL WORK UNTIL BLDG PLANS AND BLDG PERMIT ARE OBTAINED (SEC. 13-12-080; 13-32-035) | 4513 S LAFLIN ST | COMPLAINT | FAILED | View |
REPAIR/WRECK DANGER RESID PREM | 4513 S LAFLIN ST | COMPLAINT | CLOSED | View |