Last Modification Date: 2024-10-23 @ 2:45 PM
PIN: 20031210190000
Property Address: 4200 S PRAIRIE AVE
City - Zip: CHICAGO - 60653
2023 Property Class: 997
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70010
2023 Tax District: 70118
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 13 Violations
Violation Inspector Comments Address Category Status View
FILE BLDG REGISTRATION BUILDING - NOT REGISTERED 2006 THROUGH 2015 YEARS . 4200 S PRAIRIE AVE COMPLAINT FAILED View
REPAIR DOWNSPOUT FRONT BAYS , FIRST FLOOR DOWNSPOUTS SECTION MISSING . 4200 S PRAIRIE AVE COMPLAINT FAILED View
GRADE AND DRAIN LOT REAR PARKING LOT, WORN AND WEATHERED PAVEMENT COATING AND PARKING STRIPES . 4200 S PRAIRIE AVE COMPLAINT FAILED View
REPAIR FENCE FRONT IRON YARD FENCE AND GATES , RUSTED DETERIORATED WITH FLAKING PAINT . NORTH AND SOUTH SIDE YARDS , HEAVY IRON YARD GATES , SAGGING , HARD TO OPEN / CLOSE .4210 S. REAR SIX FOOT HIGH WOOD YARD FENCE AT SOUTH , ROTTED , LOOSE AND LEANING . 4200 S PRAIRIE AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR SIX FRONT CONCRETE AND IRON STAIRWAYS AND LANDINGS , SEVERELY RUSTED , DETERIORATED WITH FLAKING PAINT . STAIR TREAD PAN METAL FLANGES RUSTED OFF , SECTIONS MISSING AND LOOSE . IRON STAIR STRINGERS BLISTERED METAL RUSTED WELD AT TREAD PANS . UNDERSIDE OF DECKING AND TREADS RUSTED AND WATER DAMAGED .PERMITS REQUIRED . 4200 S PRAIRIE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM SIX REAR TWO STORY WOOD PORCHES , ALL HARDWARE , BOLTS , BRACKETS AND HANGERS , SEVERELY RUSTED AND DETERIORATED . GUARDRAILS AND HANDRAILS ONLY NAILED TO COLUMNS , MISSING CLIPS ,LOOSE . NO STAIR HEADER SUPPORT , HEADER ONLY NAILED . STAIRWAY GUARDRAILS ONLY 32 INCHES TALL WITH LARGE GAP AT BASE OF GUARDRAILS TO TOP OF STAIR TREADS , OVER SIX INCH MAXIMUM . PERMIT REQUIRED . 4200 S PRAIRIE AVE COMPLAINT FAILED View
MICE/RODENTS 4200 S. APARTMENT #2 AND 4204 S. APARTMENT #1- RODENT INFESTATION . 4200 S PRAIRIE AVE COMPLAINT FAILED View
RAT STOP AROUND EXTERIOR 4210 S. APARTMENT #1 - ALL EXTERIOR WALLS ON INTERIOR COLD AIR SEEPAGE , OPEN GAPS FOR RODENT ENTRY . 4200 S PRAIRIE AVE COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS 4200S. APARTMENT #2 AND 4210 S. APARTMENT #2 - SMOKE DETECTORS BEEPING LOW BATTERY . 4200 S PRAIRIE AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR, RESET 4200 S. APARTMENT #2 - FRONT ENTRY DOOR LOOSE HINGES SAGGING , COLD AIR INFILTRATION . 4200 S PRAIRIE AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR 4200 S. APARTMENT #2 - REAR ENTRY DOOR AND REAR STORM DOOR , COLD AIR INFILTRATION , LOOSE FRAMES AND LOCKS. NOT SECURE . 4200 S PRAIRIE AVE COMPLAINT FAILED View
CARPETING 4204 S. APARTMENT #1 -CARPETING TORN AND LOOSE BY KITCHEN . 4200 S PRAIRIE AVE COMPLAINT FAILED View
REPAIR BALCONY SIX REAR WOOD SECOND FLOOR SMALL BALCONIES GUARDRAILS ONLY NAILED TO COLUMNS , MISSING CLIPS ,LOOSE . WORN AND WEATHERED FINISH .FLOOR JOIST ONLY NAILED TO RIM JOIST , PULLING OUTWARD ,OPEN GAPS . PERMIT REQUIRED . 4200 S PRAIRIE AVE COMPLAINT FAILED View