Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 8:48 PM
PIN: 16241020020000
Property Address: 1303 S KEDZIE AVE
City - Zip: CHICAGO - 60623
2023 Property Class: 517
2023 Township: 77 - West Chicago
2023 Neighborhood: 77091
2023 Tax District: 77113
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 35 Violations
Violation Inspector Comments Address Category Status View
PROVIDE CEILING MOUNTED HEATER LACKING PROPER CLEARANCE AROUND COMBUSTIBLES. THIS POSES A DANGEROUS AND HAZARDOUS CONDITION. (18-28-920.4.2.1) 1303 S KEDZIE AVE COMPLAINT CLOSED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTORS. THIS POSES A DANGEROUS AND HAZARDOUS CONDITION. 1303 S KEDZIE AVE COMPLAINT CLOSED View
CARB MONOX DETECT IN RESID MISSING CARB0N MONOXIDE DETECTORS. THIS POSES A DANGEROUS AND HAZARDOUS CONDITION. 1303 S KEDZIE AVE COMPLAINT CLOSED View
REPAIR FLOOR INTERIOR FLOOR HAS UNEVEN SURFACES CAUSING A TRIP HAZARD. 1303 S KEDZIE AVE COMPLAINT CLOSED View
FIRE EXTNGSHR REQ, RESDNTL MISSING FIRE EXTINGUISHERS - DANGEROUS CONDITION. 1303 S KEDZIE AVE COMPLAINT CLOSED View
WORK NOT ALLOWED STEEL CHAIN LINK FENCE OVER 5 FT. REDUCE HEIGHT, REMOVE OR OBTAIN A PERMIT. 1303 S KEDZIE AVE COMPLAINT CLOSED View
REPAIR FENCE STEEL CHAIN LINK DAMAGED AND IN NEED OF REPAIR AND MISSING TOP RAILS. 1303 S KEDZIE AVE COMPLAINT CLOSED View
PROVIDE 30" BETWEEN TOILET OPENING AND SINK CABINET RESTROOM NORTHEAST ELEVATION. (18-29-405.3.1) 1303 S KEDZIE AVE COMPLAINT CLOSED View
PRV BALLCOCK,VB,OR AIR GAP MOP SINK FAUCET NORTHEAST ELEVATION. 1303 S KEDZIE AVE COMPLAINT CLOSED View
PROVIDE OPEN FRONT TOILET SEAT TOILET NORTHEAST ELEVATION. 1303 S KEDZIE AVE COMPLAINT CLOSED View
REPLACE DEFECTIVE TRAP REMOVE PVC P-TRAP AND FLEXIBLE TAIL PIECE RESTROOM NORTHEAST ELEVATION. 1303 S KEDZIE AVE COMPLAINT CLOSED View
PROVIDE SAFE PAN UNDER WATER HEATER ABOVE RESTROOM NORTHEAST ELEVATION. (18-29-504.8) 1303 S KEDZIE AVE COMPLAINT CLOSED View
PRV DISCHARGE PIPE FROM PRV DISCHARGE PIPE MISSING WATER HEATER ABOVE RESTROOM NORTHEAST ELEVATION. 1303 S KEDZIE AVE COMPLAINT CLOSED View
PROVIDE VACUUM RELIEF WATER HEATER ABOVE RESTROOM NORTHEAST ELEVATION. (18-29-504.2) 1303 S KEDZIE AVE COMPLAINT CLOSED View
PROVIDE FLOOR DRAIN FOR WATER HEATER ABOVE RESTROOM NORTHEAST ELEVATION. (18-29-412.4) 1303 S KEDZIE AVE COMPLAINT CLOSED View
LICENSED BONDED PLMBG CONTRCTR OBTAIN A LICENSED PLUMBER TO DO PLUMBING WORK. 1303 S KEDZIE AVE COMPLAINT CLOSED View
INSTALL COVERS INSTALL COVERS TO ALL OPEN BOXES ABOVE ACOUSTICAL CEILING - DANGEROUS CONDITION. 1303 S KEDZIE AVE COMPLAINT CLOSED View
DEFECTIVE FIXTURES REMOVE DEFECTIVE LIGHT FIXTURES ON EXTERIOR FRONT OF BUILDING IMPROPERLY INSTALLED. 1303 S KEDZIE AVE COMPLAINT CLOSED View
NO KEY TO USE EXIT DOOR FRONT DOOR - DOUBLE KEYED LOCK 1303 S KEDZIE AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL CRACKS IN NORTH WALL; SPALLING BRICKS AND MORTAR AT SOUTH WALL 1303 S KEDZIE AVE COMPLAINT FAILED View
REPAIR LINTELS LINTEL ABOVE AWNING DETERIORATED; PERMIT REQUIRED FOR REPLACEMENT 1303 S KEDZIE AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL NORTH/SOUTH/EAST EXTERIOR WALLS HAVE LOOSE AND MISSING MORTAR. 1303 S KEDZIE AVE COMPLAINT CLOSED View
PROVIDE REDUCED AISLES AS FOLLOWS: 33", 35", 20". PATH LEADING TO MARKED EXIT REDUCED TO 23", 29". THIS POSES A DANGEROUS AND HAZARDOUS CONDITION. (15-4-880, 15-4-900) 1303 S KEDZIE AVE COMPLAINT CLOSED View
SUBMIT 2 COPY STRUCTURAL RPT PROVIDE PROPER STRUCTURAL ENGINEER'S REPORT FOR REPLACEMENT OF STEEL LINTELS. 1303 S KEDZIE AVE COMPLAINT CLOSED View
UNAPPROVED CORDS REMOVE ALL UNAPPROVED EXTENSION CORDS - DANGEROUS CONDITION. PROVIDE PERMIT TO CORRECT VIOLATIONS. 1303 S KEDZIE AVE COMPLAINT CLOSED View
RESTORE EXIT AND EM EMERGENCY 3 SYSTEM IS INCOMPLETE - DANGEROUS CONDITION. 1303 S KEDZIE AVE COMPLAINT CLOSED View
OBSTRUCTIONS IN EXIT WAY REAR MARKED EXIT DOOR AT 32 1/2" UNDER THE REQUIRED 36". THIS POSES A DANGEROUS AND HAZARDOUS CONDITION. 1303 S KEDZIE AVE COMPLAINT CLOSED View
PROPER MATRL WATER SUPPLY PIPE REMOVE FLEXIBLE SUPPLIES TO TOILET AND LAVATORY RESTROOM NORTHEAST ELEVATION. 1303 S KEDZIE AVE COMPLAINT CLOSED View
CHIMNEY SPALLING BRICKS 1303 S KEDZIE AVE COMPLAINT FAILED View
REMOVE STOCK IN FRONT OF 3 COMPARTMENT SINK, MOP SINK AND HAND SINK NORTHEAST ELEVATION. (18-29-405.3.1) 1303 S KEDZIE AVE COMPLAINT CLOSED View
REPAIR LINTELS WEST STEEL LINTELS RUSTED WITH DEFLECTION. 1303 S KEDZIE AVE COMPLAINT CLOSED View
EXPOSED WIRING REMOVE ALL EXPOSED WIRING ABOVE ACOUSTICAL CEILING. REMOVE ALL TILES TO COMPLETE RE-INSPECTION. 1303 S KEDZIE AVE COMPLAINT CLOSED View
PROVIDE INSTALL GREASE TRAP PROPERLY NORTHEAST ELEVATION. (18-29-1003.3.6) 1303 S KEDZIE AVE COMPLAINT CLOSED View
OBTN PERMIT FOR PLUMBING WORK PERMIT FOR VIOLATIONS. 1303 S KEDZIE AVE COMPLAINT CLOSED View
(18-27-210.8) INSTALL GFCI TO BATHROOM. 1303 S KEDZIE AVE COMPLAINT CLOSED View