Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 8:20 PM
PIN: 20253020020000
Property Address: 1713 E 75TH ST
City - Zip: CHICAGO - 60649
2023 Property Class: 517
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70080
2023 Tax District: 70135
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 36 Violations
Violation Inspector Comments Address Category Status View
CLOSE BOX OPENINGS CLOSE UNUSED OPENING IN ELECTRICAL BOX OR CABINET 1713 E 75TH ST COMPLAINT FAILED View
SERVICE DROP OUT OF REACH RELOCATE SERVICE DROPS OUT OF NORMAL REACH AT REAR OF BUILDING 1713 E 75TH ST COMPLAINT FAILED View
DEFECTIVE FIXTURES REPLACE DEFECTIVE LIGHT FIXTURE IN WALKIN COOLER 1713 E 75TH ST COMPLAINT FAILED View
DEFECTIVE LIGHTING SERVICE ILLEGAL USE OF EMT IN SERVICE RUN, AND DISCONNECT NOT LOCATED WITHIN FIVE FEET OF ENTRY 1713 E 75TH ST COMPLAINT FAILED View
SOIL/WASTE,VENT PIPE MATRL PVC WASTE AND VENT BEHIND 3 COMPARTMENT SINK ON SOUTH WALL OF KITCHEN 1713 E 75TH ST COMPLAINT FAILED View
REPAIR FLOOR HOLE IN FLOOR FROM BEHIND COUNTER TO KITCHEN AREA 1713 E 75TH ST COMPLAINT FAILED View
MULTIPLE CONDUCTOR TERM IN PANEL TWO CONDUCTORS TERMINATED UNDER SINGLE BREAKER - 3X 1713 E 75TH ST COMPLAINT FAILED View
INSTALL HOOD/DUCT FOR RANGE HOOD FOR STOVE NOT FUNCTIONING PROPERLY BUSINESS FULL OF SMOKE 1713 E 75TH ST COMPLAINT FAILED View
PROVIDE NO FLOOR DRAIN FOR CONDENSATE WATER AT ICE MAKER FLOOR DRAIN MUST BE WITHIN 5 INCHES OF ICE MAKER 18-29-412.4 1713 E 75TH ST COMPLAINT FAILED View
LICENSED BONDED PLMBG CONTRCTR LICENSED PLUMBER 1713 E 75TH ST COMPLAINT FAILED View
CONTINUITY OF RACEWAY LOOSE FITTINGS, MISSING FITTING AT SERVICE PANEL 1713 E 75TH ST COMPLAINT FAILED View
INSTALL COVERS INSTALL COVER TO OPEN PANEL 1713 E 75TH ST COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE PLASTIC SUPPLY TO TOILET LAV MEN AND WOMEN RESTROOM. LAUNDRY TUB AND HAND SINK IN KITCHEN AREA AND BEHIND SERVICE COUNTER 1713 E 75TH ST COMPLAINT FAILED View
REMOVE EXPOSED CABLE ALL LIGHTS INSTALLED ABOVE DROP CEILING - ROMEX 1713 E 75TH ST COMPLAINT FAILED View
ARMORED CABLE EXPOSED RUNS AND RUN TERMINATED IN PANEL LACKS CONNECTOR 1713 E 75TH ST COMPLAINT FAILED View
INTERIOR FINISH FIRERESISTANCE PANELING ON WALLS AT FRONT AREA. 1713 E 75TH ST COMPLAINT FAILED View
DEFECTIVE FIXTURES REPLACE ALL DEFECTIVE LIGHT FIXTURES ON INTERIOR OF STOREFRONTS AND EXTERIOR LIGHTS UNDER CANOPIES. ALL EXTERIOR FIXTURES MUST BE WEATHERPROOF 1713 E 75TH ST COMPLAINT FAILED View
OBTN PERMIT FOR PLUMBING WORK PERMITS FOR VIOLATION 1713 E 75TH ST COMPLAINT FAILED View
PROVIDE OPEN FRONT TOILET SEAT NO OPEN FRONT TOILET SEATS MEN AND WOMEN'S RESTROOM 1713 E 75TH ST COMPLAINT FAILED View
STOP/REMOVE NUISANCE PROPANE TANKS STORED NEAR TO GAS OPERATED COOK STOVE TO OPERATE OUTDOOR GRILL INSIDE 1713 E 75TH ST COMPLAINT FAILED View
REPAIR BATTERY LIGHT BATTERY EMERGENCY LIGHTING IS NOT WORKING 1713 E 75TH ST COMPLAINT FAILED View
DEFECTIVE FIXTURES THROUGHOUT STORE 1713 E 75TH ST COMPLAINT FAILED View
UNAPPROVED CORDS REMOVE ALL UNAPPROVED CORDS THROUGH OUT SPACE 1713 E 75TH ST COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY 2 SOUTH EXIT DOORS MORTAR WITH SIGNS, ONE GATED AND PADLOCKED OTHER SEALED SHUT 1713 E 75TH ST COMPLAINT FAILED View
SYSTEM III INSTALL EMERGENCY LIGHTING SYSTEM III. ALL EXITS AND BATTERY PACKS MUST BE CHICAGO APPROVED 1713 E 75TH ST COMPLAINT FAILED View
CHIMNEY LOOSE BRICKS AT SOUTH CHIMNEY 1713 E 75TH ST COMPLAINT FAILED View
SERVICE DROP OUT OF REACH REMOVE ROMEX FROM LIGHT FIXTURE ON EXTERIOR AT ENTRANCE DOOR AT FRONT OF BUILDING 1713 E 75TH ST COMPLAINT FAILED View
RESTORE EXIT AND EM EXIT SIGNS ARE NOT ILLUMINATED AND LACK BATTERY BACK-UP 1713 E 75TH ST COMPLAINT FAILED View
PRV VALVE ON CW INLET TO HWHTR NO CONTROL VALVE ON COLD WATER IN LET AT WATER HEATER 1713 E 75TH ST COMPLAINT FAILED View
PROVIDE LAV IN MEN'S ROOM TO CLOSE TO FRONT OF TOILET 18-29-405.3.1 1713 E 75TH ST COMPLAINT FAILED View
PROVIDE GUTTER & DOWNSPOUT GUTTERS LEAK CAUSING MASONRY DAMAGE SOUTH WALL 1713 E 75TH ST COMPLAINT FAILED View
SEC FEEDER/BRANCH TERMINATED IN PANEL 1713 E 75TH ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL OPEN MORTAR JOINTS NEAR TO GRADE WEST AND SOUTH. OPEN MORTAR JOINTS NEAR TO ROOF LINE SOUTH 1713 E 75TH ST COMPLAINT FAILED View
18-22-210.8 INSTALL GFCI'S IN WET LOCATIONS 1713 E 75TH ST COMPLAINT FAILED View
DEFECTIVE METER EQUIPMENT REPLACE VANDALIZED AND DEFECTIVE METER SOCKET AT REAR OF BUILDING 1713 E 75TH ST COMPLAINT FAILED View
UNAPPROVED CORDS SPLICE EXTERSION CORDS AND CORD WIRING ABOVE DROP CEILING 1713 E 75TH ST COMPLAINT FAILED View