Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
FILE BLDG REGISTRATION | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View | |
WINDOW REPAIR FOR AIR SEEPAGE | 1815 W. 2ND FLOOR APARTMENT / MULTIPLE LOCATIONS - WINDOW FRAMES GAPS AND CRACKS, DRAFTY WINDOWS AND BROKEN WINDOWS WITH AIR SEEPAGE. | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 18-28-106.1 INSPECTION REQUIRED 13-32-270 WARM AIR FURNACES * ARRANGE FOR COMPLETE PERMIT INSPECTIONS AND OBTAIN PERMITS FOR WARM AIR HEATING SYSTEMS AND VENTILATION SYSTEMS WHEN WORK IS COMPLETE ALL 6 UNITS | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
SUBMIT PLANS/GET VENT PERMIT | 13-32-010 PERMIT REQUIRED 13-32-130 OPERATIONS WITHOUT PERMIT, * SUBMIT PLANS AND OBTAIN VENTILATION SYSTEM PERMIT MUST HAVE PERMIT WHEN OVER 3 UNITS | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | (VT 2034) 18-28-307 FUEL BURNING APPLIANCES THE LIQUID COMBUSTION BY PRODUCTS OF CONDENSING APPLIANCE SHALL BE COLLECTED AND DISCHARGED IN ACCORDANCE SECTION 18-28-801 * NEED TO DRAIN PROPERLY | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | 18-28-804.3.4 HORIZONTAL TERMINATION * THE VENT SYSTEM SHALL TERMINATE AT LEAST 4 FT BELOW HORIZONTALLY FROM 1 FT ABOVE ANY DOOR, WINDOW, OR AIR INTAKE | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | (VT 2031) 13-18-070 WORKMANSHIP TO MEET INTENT OF THE BUILDING PROVISION OF THIS CODE *FURNACE NEEDS TO BE WIRED TO ELECTRICAL PANEL ON ITS OWN CIRCUIT REMOVE FROM LITE | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | 1815 W. /APT. 2 - USING COOKING STOVE AS HEATING DEVICE; UNABLE TO GET ACCURATE TEMP. READING; ROOM TEMP. ¿ 68F. AT 1:28PM; HEATING SYSTEM IS OFF AT TIME OF INSPECTION; | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | 1815 W. /APT. 2 - FURNICE - OUT OF SERVICE AT TIME OF CONSTRUCTION; | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | 1815 W. /APT. 2 - FRONT AND EAST WINDOW FRAMES - BROKEN, GAPS, DRAFTY, AIR SEEPAGE; | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 18-28-106.1 INSPECTION REQUIRED 13-32-270 WARM AIR FURNACES * ARRANGE FOR COMPLETE PERMIT INSPECTIONS AND OBTAIN PERMITS FOR WARM AIR HEATING SYSTEM AND VENTILATION SYSTEMS WHEN WORK COMPLETE | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
SUBMIT PLANS/GET VENT PERMIT | 13-32-010 PERMIT REQUIRED 13-32-020,13-32-130 OPERATIONS WITHOUT PERMIT 1) SUBMIT PLANS & AND OBTAIN VENTILATING SYSTEM PERMITS A)NEED PERMIT WHEN ADDING NEW HEATING SYSTEMS IN A BUILDING OVER 3 UNITS. ALSO ANYTIME DUCT IS BEING INSTALLED | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | (VT 2031) 13-16-070 WORKMANSHIP TO MEET INTENT OF BUILDING PROVISION OF THIS CODE 1) REMOVE COAT HANGERS IN BASEMENT ON 1817 W GARFIELD THAT IS HOLDING ROUND DUCT UP AND USE METAL STRAP REMOVE PVC FLUE EXHAUSTED OVER THE SIDEWALK IN BASEMENT OF 1817 W GARFIELD NEEDS TO GO TO BACK OF HOUSE OR ROOF NEED TO SEAL DUCT WORK WITH APPROVED SEALANT OR UL LISTED TAPE | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
MAINTAIN MECH. VENT SYSTEM | 18-28-102 APPLICABILITY *MAINTAIN MECHANICAL VENTILATION EQUIPMENT IN GOOD REPAIR AND OPERATE CONDITION 1817 W GARFIELD 1ST FLR UNIT FURNACE NOT WORKING | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | OBTAIN PERMIT FOR:WOOD FENCE AT REAR OF LOT OVER 6 FEET HIGH.EXTENSIVE MASONRY WORK--REPAIR AND REPLACEMNT.REPLACEMENT OF FLAT ROOF. | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | STOP WORK UNTIL PERMIT IS OBTAINEDSECTION 13-12-080, 13-32-035. | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
FLAKY INTERIOR PAINT | ALL ELEVATIONS LOOSE AND PEELING PAINT | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR LINTELS | ALL LINTELS ABOVE WINDOWS AND BALCONY RUSTED AND SAGGING NORTH ELEVATION | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | FRONT ELEVATION FRACTURED AND MISSING MORTAR BETWEEN GREY STONE REAR 3RD FLOOR LOOSE AND MISSING SIDING | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR BALCONY | FRONT BALCONY 2 AND 3RD FLOOR FRACTURE AND LOOSE BRICK | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | REPAIR LINTELS AND BRICK WORK | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR FENCE | WEST ELEVATION FENCE MISSING TOP POLE | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | FRONT AND REAR GATE PADLOCKED AND CHAINED | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR / REBUILD SHED | GARAGE ALL ELEVATION PARAPET MISSING MORTAR SPALLING BRICKS EAST ELEVATION PARAPET MISSING BRICKS OPEN MORTAR JOINTS WOOD DOOR FAME MEMBER ROTTED DANGEROUS HAZARDOUS | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR ENCLOSED PORCH TREADS ALL DIFFERENT SIZES TREADS UNDERSIZED STRINGER ROTTED STRINGER UNDERNEATH 1ST FLOOR WOOD SHORING HOLDING TREADS IN PLACE HANDRAIL DAMAGED DECK BOARD DAMAGED 1ST FLOOR LANDING | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
WORKING ON STOP WORK ORDER | REAR PORCH | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | REAR ENCLOSED PORCH | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
USE SANITARY REFUSE CONTAINERS | REAR GARBAGE OVERFLOW 1 GARBAGE CAN | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR SKYLIGHT | SKYLIGHT CRACKED WINDOW | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
EXPOSED WIRING | 3RD FLOOR LIGHT FIXTURE EXPOSED WIRING | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | 1815 W GARFIELD BLVD | COMPLAINT | FAILED | View |