Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 5:03 PM
PIN: 20083050420000
Property Address: 1308 W 52ND ST
City - Zip: CHICAGO - 60609
2023 Property Class: 207
2023 Township: 72 - Lake
2023 Neighborhood: 72091
2023 Tax District: 72001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 10 Violations
Violation Inspector Comments Address Category Status View
PLANS & PERMITS REQ - CONTRCTR PLANS AND PERMIT FOR HOUSE AS BUILT. SEC. 13-12-050 1308 W 52ND ST COMPLAINT FAILED View
WORK CONTRARY TO PERMIT INSTALLED PLYWOOD ON EXTERIOR WALLS. PORCHES BUILT CONTRARY TO CODE AND PLANS. 1308 W 52ND ST COMPLAINT FAILED View
FINE FOR WORK DONE CONTRARY TO PLAN/CODE. SEC. 13-32-035; 13-12-080 1308 W 52ND ST COMPLAINT FAILED View
WORK CONTRARY TO PERMIT FRONT & REAR PORCHES IMPROPERLY BUILT, RISER HEIGHT NOT UNIFORM (VARIES FROM 1" TO 9"), TREAD WIDTH NOT UNIFORM (VARIES FROM 9" TO 11'), 2X12 FLOOR JOISTS AT 24" ON CENTER, SPAN 19'6", RAILS IMPROPERLY ATTACHED TO COLUMNS AND TO HOUSE; INTERIOR FIRST FLOOR TO BASEMENT MISSING HANDRAIL, REAR GRADE TO BASEMENT MISSING HANDRAIL, REAR BASEMENT ENTRANCE WATER LEAKS UNDER DOOR, WINDOWS MISSING HOLD OPEN DEVICES, SILL PLATE-MISSING BOLTS, GARAGE BUILT UP TO PROPERTY LINE, SILL PLATE MISSING BOLTS, GARAGE RAMP VERY STEEL, KNEE WALLS MISSING GYPSUM BOARD 1308 W 52ND ST COMPLAINT FAILED View
REPAIR OR REPLACE FRONT & REAR STEPS-BROKEN CONCRETE REAR RETAINING WALL BOLTS STICKING UP, GUTTERS IMPROPERLY INSTALLED (GAPS BETWEEN GUTTERS & FASCIA BOARD), HOLES AROUND PIPES IN EXTERIOR WALLS, SIDING LOOSE, FOUNDATION WALLS LEAK AT TOP 1308 W 52ND ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR PLANS & PERMIT FOR HOUSE, GARAGE, & FENCE AS BUILT 1308 W 52ND ST COMPLAINT FAILED View
WORK CONTRARY TO PERMIT FRONT & REAR PORCHES - RISERS ARE 9" TO 9 1/2" PORCH FOUNDATIONS ARE LESS THAN 42" BELOW GRADE INSTALLED REGULAR PLYWOOD EXTERIOR WALLS 1308 W 52ND ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR PLANS & PERMIT FOR HOUSE & PORCHES AS BUILT 1308 W 52ND ST COMPLAINT FAILED View
OPEN TYPE VIOLATION STOP WORK UNTIL PERMIT IS OBTAINED SECTION 13-12-080, 13-32-035 1308 W 52ND ST COMPLAINT FAILED View
STOP WORK UNTIL PERMIT IS OBTAINED, SECTION 13-12-080, 13-32-035 1308 W 52ND ST COMPLAINT FAILED View