Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING, NO RESPONSE TO VERIFY DETECTORS AND TO VERIFY COMPLAINT OF MOLD IN APT 1 AND BASEMENT. | 1616 S HARDING AVE | COMPLAINT | CLOSED | View |
OBSTRUCTIONS IN EXIT WAY | EAST AND WEST ELEVATIONS DOUBLE KEY LOCKS ON GATES. | 1616 S HARDING AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | SOUTH WALL SPALLING AT GRADE, REAR MISSING SIDING. | 1616 S HARDING AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUMBIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATION TO BASEMENT OR RESTORE THE BUILDING TO ORIGINAL STATE. | 1616 S HARDING AVE | COMPLAINT | PASSED | View |
PERMIT REQUIRED | FENCE OVER 5'FT REQUIRE PERMIT. | 1616 S HARDING AVE | COMPLAINT | PASSED | View |
CUT OR REMOVE HIGH WEEDS | REAR YARD HIGH WEEDS. | 1616 S HARDING AVE | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | PLANS AND PERMITS REQUIRED FOR OPEN AND ENCLOSED PORCH- 6X6 COLUMNS RESTING ON BLOCKS,6X6 COLUMNS TWISTING AND OVER NOTCHED BEAM TO COLUMN CONNECTION NAILED AND DISCONNECTED 10 INCH SPLICES ON 6X6 AND 4X4 COLUMNS,JOIST FACE NAILED SINGLE 2X8 HEADERS,ROTTED DECKING ROTTED,WORN AND SPLIT TREADS,LANDINGS LEANING 4 INCHES OUT OF LEVEL.GUARD AND HANDRAILS WEAK AND MISSING PICKETS,STRINGERS NAILED TO WALLS,ENCLOSED SECTION - ROTTED SIDING 6X6 DISCONECTED FROM LOOKOUT.ENTIRE PORCH WITH ROTTED MEMBERS,SPLIT AND MISSING RISERS,STAIRS WITH UNEVEN RISER HEIGHT.PORCH DANGEROUS AT THIS TIME. | 1616 S HARDING AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | BASEMENTMISSING CARBON MONOXIDE DETECTOR | 1616 S HARDING AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | REAR PORCH ENCLOSURE: SIDINGS LOOSE, BROKEN AND MISSING SECTIONS. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | EAST BASEMENT STAIRWAY - GUARDRAIL SECTIONS MISSING AT GRADE. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EAST BASEMENT TO GRADE STAIRWAY - MISSING HANDRAIL. WEST GRADE TO 1 STAIRWAY - LOOSE, BROKEN AND MISSING RAILING PICKETS. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
CHIMNEY | EAST AND WEST CHIMNEY - WASHED OUT MORTAR JOINTS. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | WEST CHIMNEY - MISSING CAPPING. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT AND REAR GATES - PADLOCKED WITH CHAINS. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BLDG. - MISSING OWNER'S I.D. SIGN. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING: NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT REAR ENCLOSED PORCH, AND TO VERIFY COMPLAINTS OF MOLD AND RODENTS IN THE BUILDING. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURE (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMEN WITH OUT PERMIT. | 1616 S HARDING AVE | COMPLAINT | PASSED | View |
REPAIR/REPLACE SMOKE DETECTORS | BASEMENT SMOKE DETECTOR NOT WORKING | 1616 S HARDING AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | REAR 3RD MISSING SECTION OF WINDOW FRAME. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S ID SIGN POSTED. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
PRV CAST IRON COVER FOR BASIN | REAR CATCH BASIN MISSING COVER. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
REPAIR BALCONY | BALCONY LINTELS RUSTED AND DETERIORATING. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH AND NORTH WALLS WASHED OUT MORTAR, REAR MISSING SIDING. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 1ST SOUTH BROKEN PANE. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
STOP ODORS RPR DFT SEWAGE SYS | BASEMENT SMELL OF SEWAGE. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH DECKING BOARDS LOOSE, WORN AND WARP, TREADS WORN AND CRACKING, STRINGERS OVERCUT AND NAIL ONLY, GRADE LOOSE RAILS, 1ST MISSING PICKETS, MOST RISERS MISSING AND SOME 11" HIGH. SUBMIT PLAN AND PERMIT FOR PORCH REPAIR. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURE (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TRO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 18-28-106.1 INSPECTION REQUIRED *ARRANGE FOR COMPLETE PERMIT INSPECTION FOR WARM AIR HEATING SYSTEMS AND VENTILATION WHEN WORK IS COMPLETED | 1616 S HARDING AVE | COMPLAINT | PASSED | View |
OPEN TYPE VIOLATION | (VT 7030) 18-28-918.9 GAS FIRED FORCED AIR WARM AIR FURNACES * WHERE A FURNACE IS INSTALLED SO SUPPLY DUCTS CARRY AIR CIRCULATED BY THE FURNACE TO AREAS OUTSIDE THE SPACE CONTAINING THE FURNACE THE RETURN AIR SHALL BE HANDLED BY A DUCT SEALED TO THE FURNACE CASING AND TERMINATING OUT SIDE THE SPACE CONTAINING THE FURNACE THE RETURN AIR SHALL BE HANDLED BY A DUCT SEALED TO THE FURNACE CASING AND TERMINATING OUT SIDE THE SPACE CONTAINING THE FRUNACE | 1616 S HARDING AVE | COMPLAINT | PASSED | View |
HEAT UNIT ADEQUATELY | ROOM TEMPERATURE 65 DEGREE'S IN 3RD FLOOR BACK BEDROOM OFF KITCHEN HEATING SYSTEM IS OFF AT TIME OF INSPECTION NO HEAT PROVIDED FURNACE HAS GAS BUT NOT IGNITING | 1616 S HARDING AVE | COMPLAINT | PASSED | View |
SAFE WORKING CONDITIONS | FURNACE OUT OF SERVICE AT TIME OF INSPECTION | 1616 S HARDING AVE | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | REAR PORCH DANGEROUS AND HARAZD, REAR PORCH 2ND ROTTED BEAMS, ALL LEVEL DECKING SHIFTING AND ROTTED BOARDS, 2ND MISSING RISERS, WEAK RAILS, JOISTS MISSING HANGER, STRINGERS NAIL ONLY, OVERCUT, CRACK AND BROKEN, HANDRAIL AT 1ST NO PICKETS, TREADS CRACK AND BROKEN. PORCH REPLACEMENT REQUIRE PLAN AND PERMIT. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
REPAIR BALCONY | BALCONY LINTEL SAGGING, LOOSE LARGE BRICKS. REQUIRE PLAN AND PERMIT FOR REPAIR. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER | FRONT GUTTER FULL OF OVERGROWN WEED AND DAMAGE. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | REAR YARD HIGH WEEDS. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | REAR ENCLOSED MISSING AND DAMAGE SIDING. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | REAR 3RD DOOR DAMAGE. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 1ST REAR CRACK PANE. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | REAR WINDOWS FRAMES ROTTED, AT NORTH 3RD INSULATION COMING OUT OF SASHES. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | 1ST REAR EXPOSED WIRING. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
RAT STOP AROUND EXTERIOR | AT REAR RATS HABORING. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
PARAPET | SOUTH AND NORTH PARAPET WALLS WASHED OUT MORTAR. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
REPAIR SCREENS | WINDOWS MISSING SCREENS. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | SMOKE DETECTOR OUT OF SERVICE | 1616 S HARDING AVE | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | REAR YARD ABANDON CARS. | 1616 S HARDING AVE | COMPLAINT | FAILED | View |