Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
INSTALL COVERS | CLOSE OPEN PANELS IN BASEMENT AND OPEN BOXES | 1337 W 72ND PL | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | IN BASEMENT (18-27-410.15) | 1337 W 72ND PL | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | REPLACE DEFECTIVE RECEPTACLES IN 1ST FLOOR LIVING ROOM,DINING ROOM | 1337 W 72ND PL | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | BUILDING HOT WATER TEMPERATURE IS 60F AT 2:10 PM | 1337 W 72ND PL | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | BUILDING ROOM TEMPERATURE IS 60F AT 2;10 PM | 1337 W 72ND PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | GRADE TO BASEMENT, NO HANDRAIL. GRADE TO 1ST,NO FOOTINGS ON COLUMNS | 1337 W 72ND PL | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT PORCH SYSTEM: WEST PIER OUT OF PLUMB. FOUR (4") WOOD SHIMS WEDGED AT TOP OF PIERS AND UNDERNEATH DECKING. LANDING SPAN IS 7X22 FEET WITH 2X8 JOISTS. DECKING BOARDS ARE BOUNCY UNDER LOAD, LANDING IS EXCESSIVELY SLOPED. STEPS GRADE TO 1ST ARE BOUNCY. 4X4 UNDERNEATH STAIRS HAVE NO FOOTINGS AND ARE SUSPENDED IN MIDAIR. COLUMNS UNDER DECKING HAVE NO FOOTINGS STEPS SLOPED UNEVENLY. ROTTED 2X. GUARDRAILS ARE NOT BOLTED, PICKETS 6" APART. PLANS AND PERMITS REQUIRED FOR REPAIRS. | 1337 W 72ND PL | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | CRACKED CONCRETE SERVICEWALK | 1337 W 72ND PL | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR BASEMENT AREA, NO GUARDRAIL. | 1337 W 72ND PL | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | GRADE TO 1ST, ROTTED TREADS WEAK UNDER LOAD. SHAKEY HANDRAILS ARE WEAK AND PICKETS SPACING INCONSISTENT. TOPRAILS WOOD SPLIT. ROTTED WOOD ON OVERCUT STRINGERS. 4X4 COLUMNS UDER STRINGERS HAVE NOT FOOTINGS AND ARE SUSPENDED MIDAIR. 2X8 JOISTS RESTING ON WOOD WEDGES THAT ARE ON TOP OF BRICK COLUMNS. COLUMNS ARE OUT PLUMB FROM LANDING TO ROOF. GUARDRAILS ARE WEAK AND PICKETS ARE SPACED OVER 4INCHES. RAIL HEIGHTS RANGE FROM 30"-36"AND NOT BOLTED TO BUILDING. DECKING BOARDS ARE WEAK AND ROTTED. PERMITS AND PLANS REQUIRED FOR REPLACEMENT OF FRONT PORCH. | 1337 W 72ND PL | COMPLAINT | FAILED | View |
REPAIR FLOOR | THRU-OUT APARTMENT FLOORS ARE EXCESSIVELY SLOPED AND UNEVEN. | 1337 W 72ND PL | COMPLAINT | FAILED | View |
FLOOR, KIT & BATH NON-ABSORB | 1ST FLOOR KITCHEN AND BATH BROKEN FLOOR TILES. | 1337 W 72ND PL | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 1ST FLOOR SMOKE DETECTORS BATTERY DEFECTIVE | 1337 W 72ND PL | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | NO CARBON MONOXIDE DETECTOR. | 1337 W 72ND PL | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | FIRST FLOOR: PARTITION WALLS BUILT IN FRONT FOYER AND 1ST BEDROOM -CLOSET FORMING A SEPARATION FOR DWELLING UNIT IN ATTIC. PLANS AND PERMITS REQUIRED FOR WORK PERFORMED. | 1337 W 72ND PL | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | CRACKED CONCRETE SERVICEWALKS. | 1337 W 72ND PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | GRADE TO 1ST STEP RISER HEIGHTS UNEVEN, HANDRAIL LOOSE, STRINGERS OVERCUT. | 1337 W 72ND PL | COMPLAINT | FAILED | View |
VACANT BUILDING - REGISTER | 1337 W 72ND PL | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 1337 W 72ND PL | COMPLAINT | CLOSED | View | |
WATCHMAN | 1337 W 72ND PL | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 1337 W 72ND PL | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 1337 W 72ND PL | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 1337 W 72ND PL | COMPLAINT | CLOSED | View | |
EXPOSED WIRING | IN BASEMENT,REMOVE OLD SERVICE ENTRY CABLES (18-27-300.4) | 1337 W 72ND PL | COMPLAINT | FAILED | View |
PROVIDE | GAS SERVICE TO BUILDING HAS BEEN DISCONNECTED SEC 7-28-060 | 1337 W 72ND PL | COMPLAINT | FAILED | View |
REPAIR FENCE | SI-FOOT WOOD FENCE-NO PERMIT | 1337 W 72ND PL | COMPLAINT | FAILED | View |
STOP LEAKING WATER | BATHROOM CEILING, WATER LEAKING | 1337 W 72ND PL | COMPLAINT | FAILED | View |
REPAIR STOOP | CRACKED CONCRETE STOOP | 1337 W 72ND PL | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | LIVING, DINING AND BEDROOMS, OUTLETS DEFECTIVE. | 1337 W 72ND PL | COMPLAINT | FAILED | View |
PROVIDE TUB/SHW TO FAMILY UNI | PAINT PEELING IN TUB. | 1337 W 72ND PL | COMPLAINT | FAILED | View |