Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING - OWNER'S I.D. SIGN NOT LEGIBLE. | 2120 S FAIRFIELD AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | FRONT ELEVATION WOOD PORCH - 4X4 COLUMNS RESTING ON CONCRETE PADS, FOUNDATION STATUS UNKNOWN. UNDERSIZED 2X6 DECK JOISTS SPAN 7'. STRINGERS ONLY NAILED TO 4X4 COLUMNS. RIM JOISTS ONLY NAILED TO COLUMNS. RAILINGS ONLY 35" HIGH, LOOSE AND PULLING. TREADS AND DECK BOARDS - WORN ROTTED AND CRACKED. PICKETS SPACED 4.25" APART. PLANS AND PERMIT REQUIRED TO REPAIR FRONT WOODEN PORCH. | 2120 S FAIRFIELD AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | ALL ELEVATIONS/ EXTERIOR MASONRY WALLS - WASHED OUT MORTAR AND SPALLING BRICKS.PERMIT REQUIRED FOR ALL MASONRY REPAIRS. | 2120 S FAIRFIELD AVE | COMPLAINT | PASSED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE - ASPHALT SIDING RIPPED WITH HOLES. DOUBLE STEEL BARN DOORS OUT OF PLUMB AND LEANING. | 2120 S FAIRFIELD AVE | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | REAR ELEVATION ATTIC/ WINDOW - BROKEN PANE. | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | CONCRETE STAIRS GRADE TO BASEMENT ARE BROKEN AND CRUMBLING. | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | BASEMENT REAR; FLOOR TILES ARE BROKEN AND LOOSE AT FRONT ROOM AND BATHROOM. | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | BASEMENT REAR; HAS WATER DAMAGE AT CHIMNEY (BUCKET COLLECTING WATER) AT SPACE HEAT FLUE. | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | WINDOWS SASH ROTTED AT BASEMENT REAR. | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | CENTER STAIRS LIGHTS NOT WORKING AT FOYER. | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | CONCRETE WALKWAY AT SOUTH ELEVATION IS CRACKED AND BROKEN. | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | FRONT PLATFORM TO BASEMENT BROKEN CONCRETE AND UNLEVEL | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | PERMIT REQUIRED FOR FENCE OVER (6) SIX FEET | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNERSHIP I.D. POSTED | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH AND SOUTH ELEVATION ERODED MORTAR, SPALLED BRICKS | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
REMOVE | REMOVE ALL SIDING USED FOR FENCING. REMOVE REAR STORAGE SHED BUILT TO ARAGE WITHOUT PERMIT | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | EAVES ROTTEN AND OPEN HARBORING PIGEONS | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR PLATFORM | SERCIVE WALK SOUTH AND EAST BROKEN & UNLEVEL CONCRETE UNAPPROVED ADDITION ADDED UNSTABLE FOUNDATION CRACKED | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
REPUTTY WINDOW PANES | DETERIORATED AND MISSING PUTTY ALL ELEVATIONS | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
RATS | REAR YARD GARAGE AND SLED EVIDENCE OF RATS | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | ALL ELEVATIONS LOOSE AND ROTTEN FRAMES | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | ALL ELEVATIONS, VARIOUS LOCATIONS BROKEN AND MISSING PANES AND STORMS | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
FLAKY INTERIOR PAINT | ALL ELEVATIONS FLAKING PAINT | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
PIGEONS-NESTING | PIGEONS ROOF LINE AND WINDOW SILLS | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT STAIRS GRADE TO 1ST DETERIORATED TREADS, STRINGERS, DECK. RAILS LOOSE AND UNDERSIZED TREADS UNDERSIZED. NO BRACING FOR 4X4 UPRIGHTS. NO JOIST CONNECTIONS FOR LANDING AT 1ST. NO FOOTINGS FOR UPRIGHTS, ON SLAB UPRIGHT SPLICE NAILED | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
UNINTERRUPTED EXIT AT GRADE | FRONT GATES DOUBLE CYLINDER KEYED DEADBOLTS | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | TRASH AND DEBRIS AREAWAY SOUTH AND EAST | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR GATE PADLOCKED | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | CHAINLINK FENCE REAR YARD DILAPIDATED | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
REPAIR / REBUILD SHED | REAR GARAGE ROTTEN AND DILAPIDATED SIDING, FRAMING, EAVES. BROKEN DOORS SERVICE AND OVERHEAD. OVERHEAD DOOR SCAB REPAIRS, SEVERE FLAKING PAINT. ATTACHED SHED DILAPIDATED | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
PROVIDE DEADLOCK FOR ENTRANCE | BASEMENT, 1ST AND 2ND FLOOR FRONT AND REAR EXITS DEADBOLT LOCKS MISSING | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | NO PEEPHOLES ALL DOORS TO EXITS EXTERIOR AND COMMON AREAS. | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | BUILDING - NO ADDRESS POSTED. | 2120 S FAIRFIELD AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | ALL ELEVATION DILAPIDATED FRAMES | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | CENTER STAIRS SWITCH MISSING COVER. | 2120 S FAIRFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT ELEVATION/ STAIRS FROM SIDEWALK TO LOWER SERVICE WALK - CONCRETE STAIRS OUT OF LEVEL AND COLLAPSING. CRACKED WITH MISSING SECTIONS. | 2120 S FAIRFIELD AVE | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | FRONT AND REAR YARDS/ ACCUMULATION OF GARBAGE, CHAIRS, MATTRESS, FURNITURE, BOTTLES, CANS, AND CONTAINERS. | 2120 S FAIRFIELD AVE | COMPLAINT | PASSED | View |