Last Modification Date: 2024-08-30 @ 5:16 PM
PIN: 13094310140000
Property Address: 4823 W GUNNISON ST
City - Zip: CHICAGO - 60630
2023 Property Class: 211
2023 Township: 71 - Jefferson
2023 Neighborhood: 71060
2023 Tax District: 71033
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 16 Violations
Violation Inspector Comments Address Category Status View
REPAIR EXTERIOR STAIR FRONT PORCH SYSTEN WITH THE FOLLOWING DEFECTS,2X10 JOIST OVERSPAND 20FT,DECKING SHOWING SIGNS OF ROTTING, INPROPER JOIT TO BEAM CONNECTIONS,PERMITS REQUIERED. 4823 W GUNNISON ST COMPLAINT PASSED View
REPAIR PORCH SYSTEM REAR PORCH SYSTEN WITH THE FOLLOWING DEFECTS, INSUFFICIENT BEAM TO COLLUM CONNECTIONS,INSUFFICIENT JOIST TO COLLUM CONNECTIONS,4X4 SUPPORT COLLUMS WITH OUT PROPER FOOTINGS,GAURD RAILS INPROPER HEIGHT (36"), PLANS AND PERMIT REQUIERED FOR REPAIRS. 4823 W GUNNISON ST COMPLAINT PASSED View
REPAIR EXTERIOR DOOR HARDWARE FRONT ENTRY DOOR WITHOUT PROPER CLOSER DEVICE. 4823 W GUNNISON ST COMPLAINT PASSED View
INSTALL DOOR VIEWING DEVICE NO PEEPHOLES IN ANY ENTRY DOORS. 4823 W GUNNISON ST COMPLAINT PASSED View
LIGHT AND VENT INSUFFICIENT AMOUNT OF OPERABLE WINDOWS IN BASEMENT APT.( GLASS BLOCK WINDOWS). 4823 W GUNNISON ST COMPLAINT PASSED View
INSTALL SMOKE DETECTORS NO WORKING SMOKE DETECTOR PRESENT IN FRONT STAIRWAY. 4823 W GUNNISON ST COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMITS FOR ALL RELATED WORK TO AUTHORIZE ALTRATIONS TO BASEMENT AND ATTIC OR RESTORE TO ORIGINAL STATE.AND DORMERS ON EAST AND WEST ELEVATIONS OF BUILDING,NO PERMITS ON FILE. 4823 W GUNNISON ST COMPLAINT FAILED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES INSTALLED IN BASEMENT AND ATTIC WITHOUT PERMITS. 4823 W GUNNISON ST COMPLAINT PASSED View
POST OWNER/MANAGERS NAME/# BUILDING - NO OWNER'S I.D. SIGN POSTED. 4823 W GUNNISON ST COMPLAINT FAILED View
PLANS & PERMITS REQUIRED SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO ATTIC ( DOUBLE DORMER 30 LINEAR FOOT BOTH EAST AND WEST ELEVATIONS ) OR RESTORE THE BUILDING TO THE ORIGINAL STATE. 4823 W GUNNISON ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT COVERED WOOD PORCH - NORTHWEST BRICK SUPPORT TWISTED AND ROTATED ON FOUNDATION . DECKING BUCKLED AT EAST AND WEST CORNERS . COLUMNS ROTTED AT BASE OF PORCH DECK. PERMIT REQUIRED FOR REPAIR.REAR OVERSIZED WOOD POOL DECK - UNKNOWN FOUNDATIONS AND FRAME STRUCTURE , NO ACCESS . ALL WOOD PICKETS LOOSE . WORN FINISH. 4823 W GUNNISON ST COMPLAINT FAILED View
REPAIR FENCE REAR FENCE MISSING AT ALLEY . FENCE OVER FIVE FOOT HIGH REQUIRES PERMITS. 4823 W GUNNISON ST COMPLAINT FAILED View
FILE BLDG REGISTRATION BUILDING - NOT REGISTERED ALL YEARS - 1990 THROUGH 2012. 4823 W GUNNISON ST COMPLAINT FAILED View
INSPECT CONSTRUCTION WORK PERMIT APPLICATION # 100394271 FOR ALTERATIONS TO 4 DWELLING UNIT BUILDING FAILED APPLICATION PROCESS AND WAS NEVER FINALIZED . 4823 W GUNNISON ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE , UNVERIFIED DETECTORS , CONDITIONS AND OCCUPANCY. 4823 W GUNNISON ST COMPLAINT FAILED View
STOP/REMOVE NUISANCE REAR YARD - LARGE OVAL ABOVE GROUND SWIMMING POOL FULL OF STAGNANT WATER. HEALTH AND SAFETY HAZARD. 4823 W GUNNISON ST COMPLAINT FAILED View