OBSTRUCTIONS IN EXIT WAY | FRONT AND REAR GATES PAD LOCKED. | 2942 W PERSHING RD | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S IDENTIFICATION SIGN MISSING. | 2942 W PERSHING RD | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | FRONT AND REAR BUILDINGS / ALL ELEVATIONS / MULTIPLE LOCATIONS - ROTTING WINDOW FRAMES. | 2942 W PERSHING RD | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | FRONT AND REAR BUILDINGS / ALL ELEVATIONS / MULTIPLE LOCATIONS - ROTTING WINDOW SASHES. | 2942 W PERSHING RD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR BUILDING, STAIRS FROM GRADE TO 1ST FLOOR - 4X4 POSTS ON CONCRETE SLAB, WITH NO FOUNDATION. LOOSE AND PULLING RAILING. STINGERS ANCHORED TO POSTS WITH NAILS ONLY. | 2942 W PERSHING RD | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | FRONT BUILDING / TWO CHIMNEY'S / CAPPING - MISSING AT BOTH. | 2942 W PERSHING RD | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | FRONT BUILDING/ 1ST FLOOR - MISSING CARBON MONOXIDE DETECTOR. | 2942 W PERSHING RD | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT BUILDING/ 1ST FLOOR - MISSING SMOKE DETECTOR. | 2942 W PERSHING RD | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | FRONT BUILDING/ 1ST FLOOR - MISSING CARBON MONOXIDE DETECTOR. | 2942 W PERSHING RD | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | FRONT BUILDING/ 1ST FLOOR - MISSING SMOKE DETECTOR. | 2942 W PERSHING RD | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | REAR PORCH TO COACH HOUSE GRADE TO 1ST FLOOR.4X4 AND 4X6 COLUMNS ERECTED ON DIRT..2X6 JOIST SPLICED WITH 1FT LAP 8' SPAN.' JOIST NAILED TO HEADERLANDING AT 1ST FLOOR LEANING AND STRINGERS.FROM GRADE TO 1ST FLOOR LEANING.STRINGERS NAILED TO WALL | 2942 W PERSHING RD | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | REAR COACH HOUSE 1 REAR APARTMENT CARBON MONOXIDE NOT WORKING | 2942 W PERSHING RD | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | REAR COACH HOUSE 1ST FLOOR REAR APARTMENT SMOKE DETECTOR NOT WORKING. | 2942 W PERSHING RD | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | FRONT COACH HOUSE 1ST 2 GLASS BLOCK BROKEN. | 2942 W PERSHING RD | COMPLAINT | FAILED | View |
REPAIR SCREENS | MISSING SCREENS THROUGH OUT. | 2942 W PERSHING RD | COMPLAINT | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING ALL APARTMENT BUT 1ST FLOOR REAR COACH HOUSE ¿ NO ENTRY, UNVERIFIED DETECTORS OCCUPANCY, AND CONDITIONS. | 2942 W PERSHING RD | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER ID NOT POSTED. | 2942 W PERSHING RD | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | FRONT AND REAR RESIDENTIAL BUILDINGS - ENTRY REFUSED TO VERIFY DETECTOR, MEANS OF EGREES AND REPAIRS MADE WITH PERMIT 100705578 ISSUED 05/16/2017. | 2942 W PERSHING RD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR COACH HOUSE, FRONT STAIRS: GUARDRAILS ARE ONLY 35" HIGH.; GUARD AND HANDRAILS ARE LOOSE TOP RAIL NOT FASTENED TO POSTS.; LANDING IS ONLY 30" DEEP.; TREADS ONLY 9-1/4" DEEP. PERMIT ONLY REQUIRED FOR REPAIRS. | 2942 W PERSHING RD | COMPLAINT | FAILED | View |
REPUTTY WINDOW PANES | WINDOWS EAST ELEVATION BROKEN AND MISSING PUTTY. | 2942 W PERSHING RD | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | METER SOCKET HANGING OOF BUILDING. REAR COACH HOUSE | 2942 W PERSHING RD | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROO 2003 TO 2017 | 2942 W PERSHING RD | COMPLAINT | FAILED | View |