The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
DEFECTIVE OUTLETS | DEFECTIVE OUTLETS THROUGHOUT 1ST AND 2ND FLOOR | 7345 S EBERHART AVE | COMPLAINT | PASSED | View |
DEFECTIVE POWER SERVICE | OPEN NEUTRAL (DANGEROUS AND HAZARDOUS) | 7345 S EBERHART AVE | COMPLAINT | PASSED | View |
DEFECTIVE FEEDER | DEFECTIVE FEEDER, NO POWER TO 2ND FLOOR | 7345 S EBERHART AVE | COMPLAINT | PASSED | View |
NO POSTED ADDRESS | FRONT OF BUILDING NO ADDRESS POSTED. | 7345 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER | SOUTH ELEVATION - SECTIONS OF GUTTER MISSING. | 7345 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | SOUTH ELEVATION SOFFIT BOARDS ROTTED. | 7345 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | ROOF ROTTED THROUGHOUT. | 7345 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR STAIRS GRADE TO 1ST FLOOR GUARD RAILS LOOSE. 1ST RISER 10 HIGH .GUARD RAILS AND STINGER NAILED TO HEADERS AND WALL | 7345 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR ENCLOSED PORCH GRADE TO 1ST FLOOR2X6 JOIST NAILED TO HEADERS.2X6 JOIST 12' SPAN.SOUTH REAR PORCH GRADE TO 2ND FLOOR 4X4 COLUMNS ERECTED ON SERVICE WALK. 2X6 JOIST NAILED TO HEADERS.LEDGER BOARD NAILED TO WALL. 2ND FLOOR LANDING DECK BOARD ROTTED. GUARD RAILS AND STINGERS NAILED TO COLUMNS,HEADERS AND WALL.GUARD RAILS 36" HIGH AND LOOSE.OLANS AND PERMIT REQUIRED FOR REPAIRS TO SOUTH PORCH. | 7345 S EBERHART AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO BASEMENT. | 7345 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST CONCRETE STAIRS HAS A BROKEN TREAD / RISER . SOUTH WOOD PORCH HAS INCORRECT RISER HEIGHTS, BROKEN STAIR STRINGERS AND TREADS . 4X4 SUPPORT COLUMNS ON SLAB, MISSING JOIST HANGERS, LEDGER NAILED. UNDERSIZED GUARDRAILD, LEDGERS NOT ATTACHED TO BUILDING PROPERLY, ROTTED GUARDRAILS. | 7345 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | ROTTED/ DETERIORATED FASCIA AND SOFFIT. | 7345 S EBERHART AVE | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | SOUTH MISSING GUTTER/ DOWNSPOUT. | 7345 S EBERHART AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | 1ST FLOOR DRYER VEINING INTO LIVING SPACE . THIS POSES A DANGEROUS AND HAZARDOUS CONDITION. CREATING A CARBON MONOXIDE HAZARD, | 7345 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 1- 2 ND FLOOR HAS NON-WORKING SMOKE DETECTORS . THIS POSES A DANGEROUS AND HAZARDOUS CONDITION. | 7345 S EBERHART AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1-2ND FLOOR HAS NON-WORKING C/O DETECTORS . THIS POSES A DANGEROUS AND HAZARDOUS CONDITION. | 7345 S EBERHART AVE | COMPLAINT | FAILED | View |
CONTRARY TO ORIGINAL PLAN | 2ND FLOOR ORIGINALLY USED FOR STORAGE . THE CURRENT USE HAS NON LOAD BEARING PARTITION WALLS FORMING A BATH , 2 BEDROOMS. | 7345 S EBERHART AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | 2ND FLOOR ORIGINALLY USED FOR STORAGE . CURRENTLY THERE ARE 2- BEDROOMS , BATH , ALL WORK WAS CONSTRUCTED WITHOUT PROPER PLANS/ PERMITS. | 7345 S EBERHART AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | WOOD PICKET FENCE OVER 5' . REDUCE HEIGHT, REMOVE OR OBTAIN PERMIT. | 7345 S EBERHART AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH ELEVATION 1ST FLOOR WINDOW MADE SMALLER PERMIT REQUIRED FOR WINDOW . | 7345 S EBERHART AVE | COMPLAINT | FAILED | View |