The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTORS IN APT.1 | 2709 W ADAMS ST | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTOR IN APT 1 | 2709 W ADAMS ST | COMPLAINT | PASSED | View |
PROVIDE | GAS SERVICE-SHUT OFF NO HEAT AND NO HOT WATER AROUND AT TIME OF INSPECTION IN APT. 1 (SEC. 7-28-060). | 2709 W ADAMS ST | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | HOT WATER SUPPLIED AT ONLY 67 DEGREES AT TIME OF INSPECTION IN APT 1 | 2709 W ADAMS ST | COMPLAINT | FAILED | View |
INT WALL/CEILING CHIP PLASTER | 1ST FLOOR THROUGH OUT APARTMENT HOLES IN WALLS | 2709 W ADAMS ST | COMPLAINT | CLOSED | View |
STOP LEAKING WATER | HOT AND COLD WATER LINES RUNNING THROUGH APARTMENT SURFACE MOUNTED ON WALLS | 2709 W ADAMS ST | COMPLAINT | CLOSED | View |
PROVIDE TRAP FOR FIXTURE | TWO BATHROOMS AND KITCHEN SINK TREADS LEAKING CAUSING BASE CABINETS TO DISASSEMBLE (ROTTING) (FALLING APART) | 2709 W ADAMS ST | COMPLAINT | CLOSED | View |
REMOVE STAGNANT WATER BSMT | BASEMENT FULL OF STAGNANT WATER | 2709 W ADAMS ST | COMPLAINT | CLOSED | View |
SAFE WORKING CONDITIONS | NO GAS LINE TO FURNACE, NO VENT STACK CONNECTOR TO FURNACE | 2709 W ADAMS ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALLS THROUGH OUT BUILDING FLAKING PAINT, ERODED MORTAR JOINTS THROUGH OUT FRONT ELEVATION, MISSING SOLIDER STONE OVER WINDOW SECOND FLOOR | 2709 W ADAMS ST | COMPLAINT | CLOSED | View |
FLAKY INTERIOR PAINT | PARAPET WALLS ON EAST AND WEST ELEVATIONS PARAPET WALLS LEANING IN TOWARDS ROOF PERMITS REQUIRED | 2709 W ADAMS ST | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | REAR PORCH SYSTEM WITH THE FOLLOWING DEFECTS, NO BOLTS BEAM TO COLUMN CONNECTIONS, IMPROPERLY CUT STRINGERS 9 INCH THREADS, 9 INCH RISE, GUARD RAILS DEFECT UNDER LOAD. PLANS AND PERMITS REQUIRED | 2709 W ADAMS ST | COMPLAINT | CLOSED | View |
STOP/REMOVE NUISANCE | HIGH WEEDS THROUGH OUT PROPERTY | 2709 W ADAMS ST | COMPLAINT | FAILED | View |
CEMENT BASEMENT FLOOR | BASEMENT FLOOR ALL DIRT (MUD) NO CONCRETE | 2709 W ADAMS ST | COMPLAINT | CLOSED | View |
STOP/REMOVE NUISANCE | HIGH WEEDS THROUGH OUT PROPERTY | 2709 W ADAMS ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL - SEVERE CRACKS AND FRACTURES BELOW 1ST AND 2ND FLOOR WINDOWS; WASHED OUT, LOOSE, CRACKED MORTAR; PEELING PAINT | 2709 W ADAMS ST | COMPLAINT | FAILED | View |
BUILDING IN DISREPAIR | NORTH - HEADSTONE AT DECORATIVE ARCH ABOVE FRONT ENTRY DOOR IS CRACKED AND FALLING; UNSECURED; DANGEROUS AND HAZARDOUS. WEST - PARAPET WALL IS COLLAPSING; UNSTABLE | 2709 W ADAMS ST | COMPLAINT | FAILED | View |
PARAPET | PARAPET WALL IS LEANING SEVERELY; LOOSE BRICKS AND MORTAR; UNSTABLE. PLANS AND PERMIT REQUIRED TO REPLACE PARAPET WALL | 2709 W ADAMS ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH - FOUNDATION STATUS UNKNOWN; 6X6 COLUMNS PULLING AWAY FROM 6X6 BEAMS; STEEL ANGLE BRACKETS NOT ATTACHED TO 6X6 BEAMS AT 1ST FLOOR; OVERNOTCHED 6X6 COLUMNS; GAPS WHERE 6X6 COLUMNS ARE SPLICED; BEAMS SHIFTING AND TOENAILED TO COLUMNS AT 2ND FLOOR- ALSO JOINED WITH GUSSET; RIM JOISTS BOWED AT STRINGER FROM 1ST TO 2ND FLOOR; STRINGER FROM 1ST TO 2ND FLOOR LEANING; LOOSE RAILS THRU-OUT; TREADS, DECKBOARDS WORN AND DETERIORATING. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH. | 2709 W ADAMS ST | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | GAS LINE MISSING AT FURNACE; VENT STACK CONNECTOR MISSING | 2709 W ADAMS ST | COMPLAINT | FAILED | View |
CEMENT BASEMENT FLOOR | GRAVEL AND DIRT FLOOR; UNFINISHED | 2709 W ADAMS ST | COMPLAINT | FAILED | View |
REMOVE STAGNANT WATER BSMT | STAGNANT WATER ON FLOOR | 2709 W ADAMS ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING/NO OWNER ID SIGN POSTED. | 2709 W ADAMS ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EAST AND WEST ELEVATION/GRADE TO 2ND FLOOR-WASHED OUT MORTAR.NORTH ELEVATION/GRADE TO PARAPET WALL-PEELING PAINT. | 2709 W ADAMS ST | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY/ MISSING CAP. | 2709 W ADAMS ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING/NO OWNER ID SIGN POSTED. | 2709 W ADAMS ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | EAST AND WEST ELEVATION/GRADE TO 2ND FLOOR-WASHED OUT MORTAR.NORTH ELEVATION/GRADE TO PARAPET WALL-PEELING PAINT. | 2709 W ADAMS ST | COMPLAINT | CLOSED | View |
CHIMNEY CAPPING | CHIMNEY/ MISSING CAP. | 2709 W ADAMS ST | COMPLAINT | CLOSED | View |
REPAIR OR REPLACE | VANITY, SINK REMOVED. (SEC. 7-28-060) | 2709 W ADAMS ST | COMPLAINT | FAILED | View |