Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 6:46 PM
PIN: 20262190110000
Property Address: 7321 S KENWOOD AVE
City - Zip: CHICAGO - 60619
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70070
2023 Tax District: 70131
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 17 Violations
Violation Inspector Comments Address Category Status View
REPLACE D&H PORCH REAR 2 STORY OPEN WOOD STAIR WITH BASEMENT ACCESS - (1) ALL WOOD STAIR MEMBERS ARE ROTTEN AND HAS COMPROMISED GENERAL STRUCTURAL STABILITY.(2) A MAJORITY OF CONNECTIONS ARE ONLY FACE NAILED OR TOE NAILED WITH THE EDGES OF WOOD MEMBERS ROTTING AND PULLING AWAY EXPOSING RUSTING NAILS - THE FEW PRESENT SCREWS ARE GRIPPING TO ROTTED WOOD MEMBERS.(3) PORCH DECK HAS ONLY 2X6 JOIST, EDGE BEAMS AND LEDGERS, ROTTEN WOOD DECKING AND ARE MISSING JOIST HANGERS AND SECURE METAL CONNECTIONS TO COLUMNS AND THE EXTERIOR WALL FACE.(4) COLUMNS ARE MISSING CODE COMPLIANT CONNECTIONS TO BEAMS AND MOST REST ON CONCRETE BLOCKS WITH UNKNOWN FOUNDATIONS.(5) VERY WEAK AND FLIMSY HANDRAILS ARE ONLY 24 INCHES HIGH AND GUARDRAILS ARE ONLY 28 INCHES HIGH - BOTH WITH WEAK PICKETS.(6) DRAWINGS AND PERMITS ARE REQUIRED. 7321 S KENWOOD AVE COMPLAINT FAILED View
PLANS & PERMITS REQUIRED (1) BASEMENT SPACES / ROOMS BUILT WITH NO PLANS OR PERMITS ON FILE WITH THE CITY OF CHICAGO.(2) BASEMENT BATHROOM - FURNACE / FORCED-AIR HEATING SYSTEM INSTALLED WITH NO DRAWINGS OR PERMIT ON FILE WITH THE CITY OF CHICAGO.(3) DRAWINGS AND PERMITS ARE REQUIRED FOR EXISTING ROOMS AND FORCED-AIR HEATING SYSTEM TO REMAIN OR A DECONVERSION PERMIT IS REQUIRED TO RESTORE THE BASEMENT TO ONE LARGE OPEN SPACE / ROOM. 7321 S KENWOOD AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR 2 STORY ENCLOSED FRAME PORCH WITH BASEMENT ACCESS -(1) BASEMENT LANDING SOUTH MASONRY BEARING WALL - CONCRETE BLOCKS NOT STACKED IN ALIGNMENT.(2) BASEMENT LANDING NORTH RETAINING WALL - BULGING OUTWARD.(3) NORTH OF BASEMENT LANDING - STORAGE OF ITEMS UNDERNEATH ENCLOSED PORCH.(4) STEPS FROM THE REAR YARD DOWN TO BASEMENT LANDING - MISSING 2 GUARDRAILS AND ONE HAND RAIL.(5) DRAWINGS AND PERMITS ARE REQUIRED. 7321 S KENWOOD AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE YARD AREA; JUNK AND DEBRIS. 7321 S KENWOOD AVE COMPLAINT FAILED View
STOP/REMOVE NUISANCE YARD AREA; ABANDON VAN. 7321 S KENWOOD AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE YARD AREA; JUNK AND DEBRIS. 7321 S KENWOOD AVE COMPLAINT CLOSED View
STOP/REMOVE NUISANCE YARD AREA; ABANDON VAN. 7321 S KENWOOD AVE COMPLAINT CLOSED View
NO HEAT - RESIDENTIAL BASEMENT BATHROOM -(1) FURNACE SERVICING BASEMENT AND 1ST FLOOR SPACES - OPEN AND NOT FUNCTIONING.(2) FURNACE MISSING CODE COMPLIANT FOUNDATION. 7321 S KENWOOD AVE COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. 18-28-106.1 INSPECTION REQUIRED 13-32-270 WARM AIR FURNACE * ARRANGE FOR COMPLETE PERMIT INSPECTIONS AND OBTAIN PERMIT FOR WARM AIR HEATING SYSTEMS AND VENTILATION SYSTEMS WHEN WORK IS COMPLETE 7321 S KENWOOD AVE COMPLAINT FAILED View
MAINTAIN MECH. VENT SYSTEM 18-28-102 APPLICABILITY *MAINTAIN MECHANICAL VENTILATION EQUIPMENT IN GOOD REPAIR AND OPERATE TO PROVIDE ADEQUATE VENTILATION (THERMOSTATED IS NOT WORKING ALSO) 7321 S KENWOOD AVE COMPLAINT FAILED View
OPEN TYPE VIOLATION (VT7011) 18-28-711 CARBON MONOXIDE DETECTOR 1) CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 18-9-908.7 THROUGH 18-9-908.12 AND 18-35-3517 FOR RESIDENTIAL 7321 S KENWOOD AVE COMPLAINT FAILED View
OPEN TYPE VIOLATION (VT 7031) 18-28-818.9.2 CENTRAL HEATING FURNACE INSTALLATIONS IN BEDROOM OR BATHROOMS SHALL BE INSTALLED IN A CLOSET LOCATED IN BED OR BATHROOM THE CLOSET SHALL HAVE A WEATHER STRIPPED SOLID DOOR WITH SELF CLOSING DEVICE, ND ALL COMBUSTION AIR SHALL BE OBTAINED FROM OUT DOORS. 2) INSTALLED DIRECTED VENT WITH 2 PIPE PAN 7321 S KENWOOD AVE COMPLAINT FAILED View
HEAT UNIT ADEQUATELY 7321 S KENWOOD 1ST FLR APT AND BASEMENT TEMPERATURE 65 DEGREE'S ON 1ST FLR 60 DEGREE'S IN BASEMENT SCHOOL AGE CHILDREN LIVING IN APT 7321 S KENWOOD AVE COMPLAINT CLOSED View
SAFE WORKING CONDITIONS WARM AIR FURNACE OUT OF SERVICE A TIME OF INSPECTION 1ST FLOOR & BASEMENT 7321 S KENWOOD AVE COMPLAINT CLOSED View
ABOVEGROUND TANK CONSTRUCTION USING COOKING STOVE AS HEATING DEVICE 1ST FLOOR & BASEMENT 7321 S KENWOOD AVE COMPLAINT CLOSED View
CARB MONOX DETECT IN RESID MISSING CARBON MONOXIDE DETECTOR 1ST FLR & BASEMENT 7321 S KENWOOD AVE COMPLAINT CLOSED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTOR 1ST FLR & BASEMENT 7321 S KENWOOD AVE COMPLAINT CLOSED View