Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPLACE D&H PORCH | REAR 2 STORY OPEN WOOD STAIR WITH BASEMENT ACCESS - (1) ALL WOOD STAIR MEMBERS ARE ROTTEN AND HAS COMPROMISED GENERAL STRUCTURAL STABILITY.(2) A MAJORITY OF CONNECTIONS ARE ONLY FACE NAILED OR TOE NAILED WITH THE EDGES OF WOOD MEMBERS ROTTING AND PULLING AWAY EXPOSING RUSTING NAILS - THE FEW PRESENT SCREWS ARE GRIPPING TO ROTTED WOOD MEMBERS.(3) PORCH DECK HAS ONLY 2X6 JOIST, EDGE BEAMS AND LEDGERS, ROTTEN WOOD DECKING AND ARE MISSING JOIST HANGERS AND SECURE METAL CONNECTIONS TO COLUMNS AND THE EXTERIOR WALL FACE.(4) COLUMNS ARE MISSING CODE COMPLIANT CONNECTIONS TO BEAMS AND MOST REST ON CONCRETE BLOCKS WITH UNKNOWN FOUNDATIONS.(5) VERY WEAK AND FLIMSY HANDRAILS ARE ONLY 24 INCHES HIGH AND GUARDRAILS ARE ONLY 28 INCHES HIGH - BOTH WITH WEAK PICKETS.(6) DRAWINGS AND PERMITS ARE REQUIRED. | 7321 S KENWOOD AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQUIRED | (1) BASEMENT SPACES / ROOMS BUILT WITH NO PLANS OR PERMITS ON FILE WITH THE CITY OF CHICAGO.(2) BASEMENT BATHROOM - FURNACE / FORCED-AIR HEATING SYSTEM INSTALLED WITH NO DRAWINGS OR PERMIT ON FILE WITH THE CITY OF CHICAGO.(3) DRAWINGS AND PERMITS ARE REQUIRED FOR EXISTING ROOMS AND FORCED-AIR HEATING SYSTEM TO REMAIN OR A DECONVERSION PERMIT IS REQUIRED TO RESTORE THE BASEMENT TO ONE LARGE OPEN SPACE / ROOM. | 7321 S KENWOOD AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 2 STORY ENCLOSED FRAME PORCH WITH BASEMENT ACCESS -(1) BASEMENT LANDING SOUTH MASONRY BEARING WALL - CONCRETE BLOCKS NOT STACKED IN ALIGNMENT.(2) BASEMENT LANDING NORTH RETAINING WALL - BULGING OUTWARD.(3) NORTH OF BASEMENT LANDING - STORAGE OF ITEMS UNDERNEATH ENCLOSED PORCH.(4) STEPS FROM THE REAR YARD DOWN TO BASEMENT LANDING - MISSING 2 GUARDRAILS AND ONE HAND RAIL.(5) DRAWINGS AND PERMITS ARE REQUIRED. | 7321 S KENWOOD AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | YARD AREA; JUNK AND DEBRIS. | 7321 S KENWOOD AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | YARD AREA; ABANDON VAN. | 7321 S KENWOOD AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | YARD AREA; JUNK AND DEBRIS. | 7321 S KENWOOD AVE | COMPLAINT | CLOSED | View |
STOP/REMOVE NUISANCE | YARD AREA; ABANDON VAN. | 7321 S KENWOOD AVE | COMPLAINT | CLOSED | View |
NO HEAT - RESIDENTIAL | BASEMENT BATHROOM -(1) FURNACE SERVICING BASEMENT AND 1ST FLOOR SPACES - OPEN AND NOT FUNCTIONING.(2) FURNACE MISSING CODE COMPLIANT FOUNDATION. | 7321 S KENWOOD AVE | COMPLAINT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 18-28-106.1 INSPECTION REQUIRED 13-32-270 WARM AIR FURNACE * ARRANGE FOR COMPLETE PERMIT INSPECTIONS AND OBTAIN PERMIT FOR WARM AIR HEATING SYSTEMS AND VENTILATION SYSTEMS WHEN WORK IS COMPLETE | 7321 S KENWOOD AVE | COMPLAINT | FAILED | View |
MAINTAIN MECH. VENT SYSTEM | 18-28-102 APPLICABILITY *MAINTAIN MECHANICAL VENTILATION EQUIPMENT IN GOOD REPAIR AND OPERATE TO PROVIDE ADEQUATE VENTILATION (THERMOSTATED IS NOT WORKING ALSO) | 7321 S KENWOOD AVE | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | (VT7011) 18-28-711 CARBON MONOXIDE DETECTOR 1) CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 18-9-908.7 THROUGH 18-9-908.12 AND 18-35-3517 FOR RESIDENTIAL | 7321 S KENWOOD AVE | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | (VT 7031) 18-28-818.9.2 CENTRAL HEATING FURNACE INSTALLATIONS IN BEDROOM OR BATHROOMS SHALL BE INSTALLED IN A CLOSET LOCATED IN BED OR BATHROOM THE CLOSET SHALL HAVE A WEATHER STRIPPED SOLID DOOR WITH SELF CLOSING DEVICE, ND ALL COMBUSTION AIR SHALL BE OBTAINED FROM OUT DOORS. 2) INSTALLED DIRECTED VENT WITH 2 PIPE PAN | 7321 S KENWOOD AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 7321 S KENWOOD 1ST FLR APT AND BASEMENT TEMPERATURE 65 DEGREE'S ON 1ST FLR 60 DEGREE'S IN BASEMENT SCHOOL AGE CHILDREN LIVING IN APT | 7321 S KENWOOD AVE | COMPLAINT | CLOSED | View |
SAFE WORKING CONDITIONS | WARM AIR FURNACE OUT OF SERVICE A TIME OF INSPECTION 1ST FLOOR & BASEMENT | 7321 S KENWOOD AVE | COMPLAINT | CLOSED | View |
ABOVEGROUND TANK CONSTRUCTION | USING COOKING STOVE AS HEATING DEVICE 1ST FLOOR & BASEMENT | 7321 S KENWOOD AVE | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTOR 1ST FLR & BASEMENT | 7321 S KENWOOD AVE | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTOR 1ST FLR & BASEMENT | 7321 S KENWOOD AVE | COMPLAINT | CLOSED | View |