PIN: 20154220060000
Property Address: 6225 S LANGLEY AVE
City - Zip: CHICAGO - 60637
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70030
2023 Tax District: 70147
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 14 Violations
Violation Inspector Comments Address Category Status View
VACANT BUILDING - REGISTER 6225 S LANGLEY AVE COMPLAINT CLOSED View
POST OWNER/MANAGERS NAME/# BUILDING /OWNER¿S I.D. SIGN ¿ MISSING; 6225 S LANGLEY AVE COMPLAINT FAILED View
REPLACE D&H PORCH REAR ELEVATION /DANGEROUS & HAZARDOUS - 2 STORY WOOD ENCLOSED PORCH;FOUNDATIONS /6X6 [ROTTED] COLUMNS ERECTED ON TOP OF CONCRETE STONE, WITH NO BASES; FOUNDATION STATUS UNKNOWN; COLUMNS /ROTTING AT CONNECTIONS; COLUMNS /6X6 SPACED UP TO 12 FEET APART;BEAMS /ROTTING, SAGGING AT FIRE CUT; PULLING OUT OF FIRE CUTS; IMPROPERLY SUPPORTED AT FIRE CUTS; BEAMS TOE NAILED TO COLUMNS; DECK JOISTS /UNDERSIZED 2X6 DECK JOISTS SPAN 12 FEET 3 INCHES; DECK JOISTS /FASTENED TO HEADER BEAM, WITH NAILS ONLY; DECKING /DECK BOARDS [UNDERSIDE] ROTTING, LOOSE, BUCKLED UP; NOTE: 6X6 COLUMNS /SEVERELY ROTTED AT GRADE ¿ SOUTHEAST CORNER ¿ OUT OF LEVEL ¿ SAGGING/SINKING;PLANS AND PERMIT REQUIRED; REAR ELEVATION /DANGEROUS & HAZARDOUS - 2 STORY WOOD [STAIR SYSTEM] PORCH;FOUNDATIONS /4X6 COLUMNS ERECTED ON TOP OF CONCRETE STONE, WITH NO BASES; FOUNDATION STATUS UNKNOWN;COLUMNS /OVER NOTCHED WITH FIRE CUTS AND RIM JOISTS CONNECTIONS OCCURRING AT THE SAME LOCATION OR IN CLOSE PROXIMITY AND ONLY 2 INCHES APART; DECK JOISTS /UNDERSIZED 2X6 DECK JOISTS SPAN 6 FEET 11 INCHES; DECK JOISTS /FASTENED TO HEADERS, WITH NAILS ONLY; STRINGERS /UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; STRINGERS, ATTACHED TO BUILDING EXTERIOR WALL, WITH NAILS ONLY; STRINGERS WEAK, OVER CUT, ROTTING, CRACKED, BROKEN;STAIRS /TREADS RANGE FRON 8 INCHES TO 9 1/4 INCHES - WORN OUT, CRACKED, BROKEN, ROTTING, WEAK; PORCH UNSTABLE, LANDING ¿ EXCESSIVE PULLING, SWAYING; DECKING /DECK BOARDS ROTTING, LOOSE, BUCKLED UP; PLYWOOD USED AS DECKING MATERIAL [FOR UNENCLOSED EXTERIOR PORCH SYSTEM]; RAILINGS /GUARD RAILING SECTIONS ONLY 37 INCHES HIGH - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; STAIR RAILING SECTIONS ONLY 30 INCHES HIGH - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; ALL RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALL WITH NAILS /SCREWS ONLY; PICKETS - MISSING; PICKETS SPACED UP TO 11 INCHES APART;PLANS AND PERMIT REQUIRED; 6225 S LANGLEY AVE COMPLAINT FAILED View
REPAIR COPING FRONT ELEVATION /METAL COPING - RUSTED, WITH LARGE HOLES; 6225 S LANGLEY AVE COMPLAINT FAILED View
DEMO DEBRIS REAR YARD, UNDER ENCLOSED DANGEROUS & HAZARDOUS 2 STORY WOOD PORCH AND GARAGE /EXCESSIVE CONSTRUCTION DEBRIS; 6225 S LANGLEY AVE COMPLAINT FAILED View
REPAIR GUTTER REAR ELEVATION /ROOF GUTTER - RUSTED WITH HOLES; 6225 S LANGLEY AVE COMPLAINT FAILED View
REPAIR FENCE REAR YARD GATE /BROKEN, PICKETS - MISSING; 6225 S LANGLEY AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL REAR ELEVATION /EXTERIOR FRAME WALL - ALUMINUM SIDING ¿ MISSING, LOOSE AND HANGING; EXTERIOR PLYWOOD - ROTTED, MISSING; 6225 S LANGLEY AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR HARDWARE FRONT ELEVATION /EXTERIOR DOOR HARDWARE - MISSING; 6225 S LANGLEY AVE COMPLAINT FAILED View
PLANS & PERMITS REQUIRED FRONT ELEVATION /7 [SEVEN] METAL WINDOW LINTELS - REPLACED WITHOUT PERMIT; 6225 S LANGLEY AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR INTERIOR ALTERATIONS OF EXISTING 2 STORY BUILDING INCLUDING BU NOT LIMITED TO:REMOVING AND RELOCATING PARTITIONS. 6225 S LANGLEY AVE COMPLAINT FAILED View
BLANK-TEXT MUST CITE CODE SECT STOP ALL WORK ON PREMISES UNTIL PLANS ARE APPROVED AND PERMIT IS OBTAINEDSECTION 12-080, 13-32-035. 6225 S LANGLEY AVE COMPLAINT FAILED View
REPAIR AREAWAY WALL SOUTH ELEVATION /AREAWAY CEILING - ROTTED - NON-COMBUSTIBLE MATERIAL; 6225 S LANGLEY AVE COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED GARAGE /SERVICE DOOR - TOO SMALL FOR FRAME, WITH GAPS AT BOTTOM; WEST ELEVATION /EAVES - ROTTING, LOOSE HANGING METAL CAPPING; 6225 S LANGLEY AVE COMPLAINT FAILED View