Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
DWELLING CLEAN AND SANITARY | BASEMENT APARTMENTS WITH SEVERE MOLD AND MILDEW | 6547 S DREXEL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | REAR EXTERIOR DOOR ROTTED | 6547 S DREXEL AVE | COMPLAINT | FAILED | View |
KEEP FIXTUR CLEAN AND SANITARY | BASEMENT APARTMENT TUB UNSANITARY WITH RAW SEWAGE | 6547 S DREXEL AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING CHIP PLASTER | UNFINISHED DRYWALL LARGE HOLES IN BASEMENT APARTMENTS | 6547 S DREXEL AVE | COMPLAINT | FAILED | View |
HEATING PLANT ENCLOSURE | ENCLOSE BASEMENT HEATING PLAN ROOM ONE HOUR FIRE RESIST | 6547 S DREXEL AVE | COMPLAINT | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | PROVIDE CLASS B DOOR FOR HEATING PLANT ROOM | 6547 S DREXEL AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | OBTAIN PLANS AND PERMITS TO REPAIR PORCH BEAM COLUMN CONNECTION DEFICIENT NOTCHED INTO COLUMN WITH LIGHT GAUGE METAL PLATE STRINGERS UNDERSIZED WITH WEAK CONNECTIONS AT LANDINGS BEAMS JOISTS AND HEADER JOIST OVERSPANNED 42' FOUNDATIONS REQUIRED GUARDRAILS LESS THAN 42' WITH WEAK RAILS AND CONNECTIONS NOT JOIST HANGERS NO BOLTED CONNECTIONS | 6547 S DREXEL AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLANS AND PERMITS FOR TWO BASEMENT APARTMENTS INCLUDING PLUMBING ELECTRICAL HVAC AND ALL WALLS FORMING ROOMS | 6547 S DREXEL AVE | COMPLAINT | FAILED | View |
EGRESS -BASEMENT | BASEMENT APARTMENTS SECOND EGRESS IS THROUGH MECHANICAL ROOM | 6547 S DREXEL AVE | COMPLAINT | FAILED | View |
SEPARATION OF DWELLING ADEQUAT | BASEMENT CEILING 1/2' DRYWALL | 6547 S DREXEL AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT APARTMENTS MISSING SMOKE DETECTOR | 6547 S DREXEL AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT APARTMENT MISSING CARBON MONOXIDE DETECTOR | 6547 S DREXEL AVE | COMPLAINT | FAILED | View |
VACANT BUILDING - REGISTER | 6547 S DREXEL AVE | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 6547 S DREXEL AVE | COMPLAINT | CLOSED | View | |
LIGHT AND VENT | PROVIDE ADEQUATE LIGHT AND VENTILATION IN BASEMENT APARTMENTS GLASS BLOCK WINDOWS | 6547 S DREXEL AVE | COMPLAINT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 6547 S DREXEL AVE | PERMIT | PASSED | View | |
OPEN | 6547 S DREXEL AVE | PERMIT | PASSED | View |