The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | REAR PORCH, GUARDRAILS END POSTS TO WALL - MISSING LAGBOLTS. | 1645 W GARFIELD BLVD | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - MISSING OWNER'S ID. SIGN. | 1645 W GARFIELD BLVD | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | BUILDING - NO ADDRESS POSTED. | 1645 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | BASEMENT ENTRANCE - EXTERIOR WALLS HAVE OPEN MORTAR JOINTS | 1645 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR LINTELS | LINTELS ABOVE DOOR AND WINDOW RUSTED; DEFECTIVE | 1645 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR BALCONY | 2ND FLOOR BALCONY - BROKEN LIMESTONE AT WEST WALL | 1645 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | CRACKS IN CONCRETE STAIRS FROM GRADE TO 1ST FLOOR, IMPROPER HANDRAILS; BASEMENT STAIRS HAVE BROKEN CONCRETE | 1645 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR OPEN WOOD PORCH - NO VISIBLE FOOTINGS ABOVE GROUND AT COLUMNS; 6X6 COLUMNS HAVE ABANDON NOTCHES FILLED WITH SCAB WOOD; 1ST FLOOR DECK BOARDS BOWED; RIM JOISTS BOWED AT 1ST FLOOR AND STAIR LANDING; 1ST FLOOR JOISTS UNDERSIZED FOR SPAN OF DECK; GUARDRAILS LESS THAN 42" HIGH; PICKETS MISSING AT GUARDRAILS; LEDGER BOARDS NOT BOLTED TO WALL; NO RISER BOARDS; TREADS ONLY 91/2" WIDE; CONNECTIONS AND STAIR STRINGERS NOT BOLTED; NO JOIST HANGERS; OBTAIN PLANS AND PERMIT FOR REPAIRS OR REPLACEMENT OF REAR PORCH | 1645 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | REAR DOWNSPOUT - SECTION MISSING FROM GRADE TO 1ST FLOOR | 1645 W GARFIELD BLVD | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR AT TIME OF INSPECTION; UNVERIFIED COMPLAINT (SR- 901715141) OF WATER RUNNING FROM TENANT AT 2ND FLOOR; | 1645 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTHE ELEVATION - BASEMENT ENTRANCE , OPEN MORTAR JOINTS. | 1645 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR STAIRS - GRADE TO BASEMENT , BROKEN CONCRETE TREADS. REAR GRADE TO 1ST FLOOR BROKEN CONCRETE TREADS AND RAILING SECTIONS ARE IMPROPER OF "LADDER" TYPE DESIGN. | 1645 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR PORCH - 6X6 COLUMNS BOWED, FOUNDATION STATUS UNKNOWN. BEAMS POCKETS NO VISIBLE METAL TIES . 6X6 COLUMNS NOT ATTACHED TO WALL (FREE STANDING) . LEDGER BEAMS MISSING BOLTS, NO ATTACHMENT AT WALL.RAILING SECTIONS MISSING PICKETS 1ST AND 2ND FLOOR. OPEN RISER DESIGN WITH RISER HEIGHT 10 INCHES. . ONE SWAY BRACE INSTALLED, 1ST AND 2ND FLOOR DECK MISSING JOIST HANGERS. PICKETS LOOSE , MISSINGG, AND NAILED ON THE OUTSIDE OF RAILING SECTIONS. 1ST FLOOR DECK OVERSIZED AND PROJECTING MORE THAN 10 FEET AWAY FROM BUILDING. PLANS AND PERMIT REQUIRED TO REPLACE REAR PORCH. | 1645 W GARFIELD BLVD | COMPLAINT | FAILED | View |
OBTAIN OR POST PERMIT | 1645 W GARFIELD BLVD | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 1645 W GARFIELD BLVD | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 1645 W GARFIELD BLVD | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 1645 W GARFIELD BLVD | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 1645 W GARFIELD BLVD | COMPLAINT | CLOSED | View | |
WATCHMAN | 1645 W GARFIELD BLVD | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 1645 W GARFIELD BLVD | COMPLAINT | CLOSED | View | |
ARRANGE COMPLETED PERMIT INSP. | 18-28-106.1 INSPECTION REQUIRED 13-32-270 WARM AIR FURNACES,ARRANGE FOR COMPLETE PERMIT INSPECTIONS AND VENTILATION SYSTEMS WHEN WORK IS COMPLETED | 1645 W GARFIELD BLVD | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | (VT 2035) 13-28-307.2.2 DRAIN PIPE MATERIALS LAND SIZES 18-28-307.2.3 AUXILIARY DRAIN PANS 18-28-307.2.4 SECONDARY DRAIN SYSTEM | 1645 W GARFIELD BLVD | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | (VT 7011 CARBON MONOXIDE DETECTORS: CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH SECTIONS 18-9-908.7 THROUGH 18-9-908.12 AND 18-35-3517 FOR RESIDENTIAL | 1645 W GARFIELD BLVD | COMPLAINT | FAILED | View |
SUBMIT PLANS/GET VENT PERMIT | 1645 W GARFIELD BLVD | PERMIT | FAILED | View | |
ARRANGE COMPLETED PERMIT INSP. | 1645 W GARFIELD BLVD | PERMIT | FAILED | View | |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALK - BROKEN CONCRETE | 1645 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR LINTELS | NORTH ELEVATION - LINTELS RUSTED. | 1645 W GARFIELD BLVD | COMPLAINT | FAILED | View |