Chicago Building Violations Data: 34 Violations
Violation Inspector Comments Address Category Status View
OPEN 5332 S KEDZIE AVE PERMIT CLOSED View
PLANS & PERMITS REQ - CONTRCTR PERMIT FOR STAGE & DJ BOOTH 5332 S KEDZIE AVE PERIODIC PASSED View
PLANS & PERMITS REQ - CONTRCTR PROVIDE DOCUMENTATION FOR BEAM COLUMN AT BASEMENT (BY STAIRS) ERECTION OF OFFICE IN BASEMENT & 2HR CEILING AT BASEMENT. 5332 S KEDZIE AVE PERIODIC PASSED View
OBSTRUCTIONS IN EXIT WAY REAR EXIT DOORS OBSTRUCTEDW/THUMBTURN LOCKS, REAR EXIT DOORS ON SOUTH & WEST HAVE EXCESSIVELY SLOPED RAMPS WHICH CAUSE TRIP HAZARD. 5332 S KEDZIE AVE PERIODIC PASSED View
PROVIDE PROVIDE 2HR FIRE RATED CEILING AT BASEMENT (SEE 15-8-240) (W.I.P) 5332 S KEDZIE AVE PERIODIC PASSED View
PLANS & PERMITS REQ - CONTRCTR PROVIDE DOCUMENTATION FOR BEAM COLUMN AT BASEMENT (BY STAIRS)ERECTION OF OFFICE IN BASEMENT & 2HR CEILING AT BASEMENT.(W.I.P) 5332 S KEDZIE AVE PERIODIC PASSED View
OBSTRUCTIONS IN EXIT WAY REAR EXIT DOORS OBSTRUCTED W/THUMB TURN LOCKS, REAR EXIT DOORS ON SOUTH & WEST HAVE EXCESSIVELY SLOPED RAMPS WHICH CAUSE TRIP HAZARD (W.I.P) 5332 S KEDZIE AVE PERIODIC PASSED View
ARRANGE PREMISE INSPECTION NO ENTRY TO 2 FLOOR 5332 S KEDZIE AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM NORTH WOOD STAIRS 1 FLOOR/BASEMENT HAS LOOSE AND WORN TREADS 5332 S KEDZIE AVE COMPLAINT FAILED View
PROVIDE EXPOSED FLOOR JOIST ABOVE DROP CEILING IN BASEMENT NEED SPECS FOR DROP CEILING SHOWING ITS A IHR FIRE RATED CEILING SYSTEM 6(13-60-200) 5332 S KEDZIE AVE COMPLAINT FAILED View
PROVIDE HOT WATER TANK IN BASEMENT HAS BACK PITCHED FLUE PIPE (18-28-803-10.5) DANGEROUS CONDITION 5332 S KEDZIE AVE COMPLAINT FAILED View
REPAIR DOOR HARDWARE MEN/WOMEN REST ROOMS ARE MISSING HANDLES 5332 S KEDZIE AVE COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH 2 FLOOR UNIT HAS A REAR EGRESS AT THE WEST ELEVATION THERE ARE PARAPETS ON THE NORTH/SOUTH ELEVATIONS THAT ARE UNDERSIZED 5332 S KEDZIE AVE COMPLAINT FAILED View
RESTORE EXIT AND EM MAINTAIN SYSTEM III IN OPERABLE CONDITION. INSTALL EXIT SIGN TO REAR EXIT DOOR 5332 S KEDZIE AVE COMPLAINT FAILED View
18-27-210.8 INSTALL GROUND FAULT CIRCUIT INTERRUPTER TO WET LOCATIONS BAR AREA AND BATHROOMS 5332 S KEDZIE AVE COMPLAINT FAILED View
INSTALL COVERS INSTALL COVERS TO ALL OPEN JUNCTION BOXES AND DEVICES 5332 S KEDZIE AVE COMPLAINT FAILED View
18-27-110.26 MAINTAIN MINIMUM CLEARANCE TO ALL ELECTRICAL EQUIPMENT IN ELECTRICAL ROOM REMOVE ALL FOREIGN OBJECTS IN ELECTRICAL ROOM 5332 S KEDZIE AVE COMPLAINT FAILED View
13-12-360 PROVIDE PERMIT TO CORRECT VIOLATIONS 5332 S KEDZIE AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO 2ND FLOOR AND BASEMENT (14A-1-104.7) 5332 S KEDZIE AVE COMPLAINT PASSED View
OBSTRUCTIONS IN EXIT WAY REAR 2ND FLOOR ROOF WALKWAY HAS GARBAGE AND DEBRIS AND NOT ALLOWING FREE ACCESS FROM EGRESS THIS POSES A DANGEROUS AND HAZARDOUS CONDITION AND ELECTRIC METER PARTIALLY BLOCKING STAIRS (14X5-505.1.2) 5332 S KEDZIE AVE COMPLAINT PASSED View
MIXED OCCUPANCY SEPARATION BREACH IN FIRE SEPARATION FROM COMMERCIAL SPACE TO RESIDENTIAL ABOVE THIS POSES A DANGEROUS AND HAZARDOUS CONDITION (14B-5-508) 5332 S KEDZIE AVE COMPLAINT PASSED View
POST APPROVED OCCUPANCY CARD MISSING OCCUPANCY CARD (14A-8-802) 5332 S KEDZIE AVE COMPLAINT PASSED View
REPAIR EXTERIOR DOOR EAST MARKED EXIT DOOR HAS BROKEN PANIC HARDWARE THIS POSES A DANGEROUS AND HAZARDOUS CONDITION(14X-3-303.13) 5332 S KEDZIE AVE COMPLAINT PASSED View
REPAIR INTERIOR WALLS/CEILING WEST REAR MARKED EXIT DOOR HAS RUSTED STEEL FRAMING @ HEADER (14X-3-304.3) 5332 S KEDZIE AVE COMPLAINT PASSED View
FIRE EXTNGSHR RECHARGE & TAG FIRE EXTINGUISHER HAS OUT DATED TAG (14X-5-504.5) 5332 S KEDZIE AVE COMPLAINT PASSED View
SERVICE WALK, PASSAGE, AREAWAY EAST ENTRY WAY HAS BROKEN TILES CAUSING A TRIP HAZARD (14X-3-302.4) 5332 S KEDZIE AVE COMPLAINT PASSED View
REPAIR FLOOR FLOOR BEHIND BAR HAS DAMAGED FLOORING (14X-3-304.4) 5332 S KEDZIE AVE COMPLAINT PASSED View
OPEN 5332 S KEDZIE AVE PERMIT CLOSED View
OPEN 5332 S KEDZIE AVE PERMIT FAILED View
OPEN TYPE VIOLATION DENIED CAP 1"LINE FROM OLD ICE MAKER.CORRECT LAVATORY WASTE IN MEN'S WASHROOM 5332 S KEDZIE AVE PERMIT CLOSED View
PROVIDE PROVIDE 2HR FIRE RATED CEILING AT BASEMENT (SEE 15-8-240) 5332 S KEDZIE AVE PERIODIC PASSED View
ILLUMINATE PUBLIC STAIR/HALL INSTALL/REPAIR E.M. LIGHTING IN BATHROOMS. 5332 S KEDZIE AVE PERIODIC PASSED View
INSTALL EXIT SIGN INSTALL ADDITIONAL EXIT SIGN WITH ARROW POINTING TO EXIT AT THE SOUTH ELEVATION 5332 S KEDZIE AVE PERIODIC PASSED View
POST APPROVED OCCUPANCY CARD POST OCC CARD ON THE WALL. 5332 S KEDZIE AVE PERIODIC PASSED View