Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
OBTN PERMIT FOR PLUMBING WORK | PULL PERMIT | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | BASEMENT BOILER ROOM CLASS "B" DOOR FRAME AND CLOSER | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
CLASS B DOOR IN STAIRWELL | STAIRWELL DOORS - SOME DOORS ARE CLASS "B" BUT FRAMES ARE WOOD AND MISSING CLOSERS | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
PROVIDE | PROVIDE EVACUATION DIAGRAMS TO ALL ROOMS (15-4-850) | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMITS FOR CONVERSION OF 6 FLAT BUILDING TO ROOMING UNITS. APPROXIMATELY 27 UNITS INCLUDING 3 IN BASEMENT - PLAN AND PERMITS TO INCLUDE ALL PLUMBING AND ELECTRICAL. | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | HIRE LICENSED AND BONDED PLUMBING CONTRACTOR | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
INSTALL TRAP,WASTE,VENT PIPES | PROVIDE WASTE, VENT AND TRAPS FOR ALL KITCHEN SINKS THROUGHT OUT THE BUILDING (18-29-1001.1) | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
PROVIDE | PROVIDE EITHER BALANCED PRESSURE ON THERMOSTATIC (OR COMBINATION) MIXING VALVES ON TUB, SHOWERS, THROUGHOUT THE BUILDING. (18-29-424.4.4) | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REPLACE ALL FLEXIBLE WATER SUPPLIES WITH SOLID ONES ON THE FIXTURES AND THE WATER HEATER. | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
INDIRECT CONN.FOR WATER SUPPLY | PROVIDE REDUCE PRESSURE ZONE (R.P.2.) FOR COLD WATER MAKEUP WATER TO BOILER | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
RMV DFT PIPE,FITTING,FIXTURE | REPLACE WATER HEATER WITH PROPER SIZE HEATER 50 GALLON NOW - 27 UNITS. MOVE ALL GARBAGE FROM AROUND HEATER. | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | PROPERLY ILLUMINATE REAR STAIRWAY AND HALLWAYS. (18-27-720.6) | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST MANAGEMENT INFORMATION | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT INTERIOR STAIRS - LOOSE MARBLE TREADS | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT EAST STAIRS TO BASEMENT GANGWAY NO HANDRAIL | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | EAST ELEVATION ABOVE 3RD CORNICE - MISSING LIMESTONE, OPEN MORTAR JOINTS | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR YARD - ABANDONED VEHICLE, JUNK AND DEBRIS | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
ABANDONED REFRIGERATOR | REAR YARD ABANDONED REFRIGERATOR | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | REAR YARD AT NORTH GANGWAY - PLAN AND PERMIT FOR WOODEN SHED | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
RATS-ELEVATE MATERIAL 18" | NORTH GANGWAY AND BASEMENT - ELEVATE ALL WOOD | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | REAR ENCLOSED PORCH - PLANS AND PERMITS FOR PORCH ENCLOSURE | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR ENCLOSED PORCH - UNDERSIZED JOISTS, IMPROPER STRINGER CONNECTIONS, LOOSE RAILS AND HANDRAILS. | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PERMIT AND PLANS TO BRING REAR PORCH UP TO PRESENT CODE. | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR PORCH EGRESS BLOCKED BY APPLIANCES AND LADDERS; BASEMENT EXIT CORRIDOR BLOCKED BY REFRIGERATOR. | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BOILER ROOM - NO CARBON MONOXIDE DETECTOR | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | FRONT AND REAR STAIRWELLS - DEFECTIVE SMOKE DETECTORS | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
CARPETING | UNSANITARY CARPETING THROUGHOUT BUILDING | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | PROVIDE WORKING VIEWING DEVICES TO ALL ROOMING UNIT ENTRY DOORS | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | INSTALL GROUND FAULT CIRCUIT INTERRUPING RECEPTACLES BY ALL SINKS | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
INSTALL FIRE ALARM SYSTEM WHERE REQUIRED (18-27-760.80) | 2834 N ALBANY AVE | COMPLAINT | FAILED | View | |
ARRANGE PREMISE INSPECTION | NO ENTRY. | 2834 N ALBANY AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 2836- 3RD FLOOR FRONT BROKEN WINDOW AND BOARDED UP. | 2834 N ALBANY AVE | PERIODIC | FAILED | View |
NO KEY TO USE EXIT DOOR | REAR EXIST PAD LOCKED. | 2834 N ALBANY AVE | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | ABANDONED VEHICLES IN REAR YARD. | 2834 N ALBANY AVE | PERIODIC | FAILED | View |
NO POSTED ADDRESS | NO MANAGEMENT SIGN. | 2834 N ALBANY AVE | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | REAR WOODEN SHED AND NORTH GANGWAY MAJOR DEBRIS - FIRE HAZARD | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
INSTALL FIXTURES PROPERLY | REPLACE VANITY IN UNIT# 108 | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
PROVIDE ADEQUATE SUPPORT | PROVIDE ADEQUATE HANGERS FOR ALL HORIZONTAL PIPING IN BASEMENT (WASTE, WATER, AND GAS) | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
PROVIDE TRAP FOR FIXTURE | PROVIDE TRAP FOR LAVATORY IN UNIT# 201 | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
COVER OUTLETS AND JBS | SWITCH COVERS MISSING VARIOUS LOCATIONS 2ND FLOOR ROOMS | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | FRONT EAST NORTH 3RD FLOOR WINDOWS BOARDED | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | INSTALL BATTERY BACK-UP TYPE EXIT SIGNS (THROUGHOUT) (18-27-700.44) | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
STOP LEAKING WATER | STOP LEAKING WATER IN UNIT# 107 AND BASEMENT | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | (18-29-105.4.4) REMOVE FIXTURES, WATER SUPPLIES, SOIL, WASTE AND VENT PIPING INSTALLED WITHOUT PERMIT. | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | PROVIDE SMOKE DETECTORS - BASEMENT THROUGH 3RD CORRIDORS AND ROOMS 108, 201, 207. | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WATER PIPING | RE-PIPE ALL HORIZONTAL WATER PIPING IN BASEMENT WITH PROPER MATERIALS | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING FIXTURES | REMOVE EXPOSED WIRING AT LIGHT FIXTURE IN ROOMS #104,208,205 | 2834 N ALBANY AVE | COMPLAINT | FAILED | View |